Literature DB >> 24595349

Convection-reaction equation based magnetic resonance electrical properties tomography (cr-MREPT).

Fatih S Hafalir, Omer F Oran, Necip Gurler, Yusuf Z Ider.   

Abstract

Images of electrical conductivity and permittivity of tissues may be used for diagnostic purposes as well as for estimating local specific absorption rate distributions. Magnetic resonance electrical properties tomography (MREPT) aims at noninvasively obtaining conductivity and permittivity images at radio-frequency frequencies of magnetic resonance imaging systems. MREPT algorithms are based on measuring the B1 field which is perturbed by the electrical properties of the imaged object. In this study, the relation between the electrical properties and the measured B1 field is formulated for the first time as a well-known convection-reaction equation. The suggested novel algorithm, called "cr-MREPT," is based on the solution of this equation on a triangular mesh, and in contrast to previously proposed algorithms, it is applicable in practice not only for regions where electrical properties are relatively constant but also for regions where they vary. The convective field of the convection-reaction equation depends on the spatial derivatives of the B1 field, and in the regions where its magnitude is low, a spot-like artifact is observed in the reconstructed electrical properties images. For eliminating this artifact, two different methods are developed, namely "constrained cr-MREPT" and "double-excitation cr-MREPT." Successful reconstructions are obtained using noisy and noise-free simulated data, and experimental data from phantoms.

Mesh:

Year:  2014        PMID: 24595349     DOI: 10.1109/TMI.2013.2296715

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  16 in total

1.  Mapping electrical properties heterogeneity of tumor using boundary informed electrical properties tomography (BIEPT) at 7T.

Authors:  Yicun Wang; Qi Shao; Pierre-Francois Van de Moortele; Emilian Racila; Jiaen Liu; John Bischof; Bin He
Journal:  Magn Reson Med       Date:  2018-09-19       Impact factor: 4.668

2.  Simultaneous Quantitative Imaging of Electrical Properties and Proton Density From B1 Maps Using MRI.

Authors:  Pierre-Francois Van de Moortele
Journal:  IEEE Trans Med Imaging       Date:  2016-09       Impact factor: 10.048

3.  Magnetic resonance electrical property mapping at 21.1 T: a study of conductivity and permittivity in phantoms, ex vivo tissue and in vivo ischemia.

Authors:  Ghoncheh Amouzandeh; Frederic Mentink-Vigier; Shannon Helsper; F Andrew Bagdasarian; Jens T Rosenberg; Samuel C Grant
Journal:  Phys Med Biol       Date:  2020-02-28       Impact factor: 3.609

4.  In vivo imaging of electrical properties of an animal tumor model with an 8-channel transceiver array at 7 T using electrical properties tomography.

Authors:  Jiaen Liu; Qi Shao; Yicun Wang; Gregor Adriany; John Bischof; Pierre-Francois Van de Moortele; Bin He
Journal:  Magn Reson Med       Date:  2017-01-23       Impact factor: 4.668

5.  Theoretical Investigation of Random Noise-Limited Signal-to-Noise Ratio in MR-Based Electrical Properties Tomography.

Authors:  Seung-Kyun Lee; Selaka Bulumulla; Ileana Hancu
Journal:  IEEE Trans Med Imaging       Date:  2015-05-01       Impact factor: 10.048

6.  CONtrast Conformed Electrical Properties Tomography (CONCEPT) Based on Multi- Channel Transmission and Alternating Direction Method of Multipliers.

Authors:  Yicun Wang; Pierre-Francois Van De Moortele; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2018-08-13       Impact factor: 10.048

7.  Magnetic-Resonance-Based Electrical Property Mapping Using Global Maxwell Tomography With an 8-Channel Head Coil at 7 Tesla: A Simulation Study.

Authors:  Ilias I Giannakopoulos; Jose E C Serralles; Luca Daniel; Daniel K Sodickson; Athanasios G Polimeridis; Jacob K White; Riccardo Lattanzi
Journal:  IEEE Trans Biomed Eng       Date:  2020-12-21       Impact factor: 4.538

8.  Electrical Properties Tomography Based on $B_{{1}}$ Maps in MRI: Principles, Applications, and Challenges.

Authors:  Jiaen Liu; Yicun Wang; Ulrich Katscher; Bin He
Journal:  IEEE Trans Biomed Eng       Date:  2017-08-21       Impact factor: 4.538

9.  Accuracy and precision of electrical permittivity mapping at 3T: the impact of three B 1 + mapping techniques.

Authors:  Soraya Gavazzi; Cornelis A T van den Berg; Alessandro Sbrizzi; H Petra Kok; Lukas J A Stalpers; Jan J W Lagendijk; Hans Crezee; Astrid L H M W van Lier
Journal:  Magn Reson Med       Date:  2019-02-08       Impact factor: 4.668

10.  An MR-Based Viscosity-Type Regularization Method for Electrical Property Tomography.

Authors:  Changyou Li; Wenwei Yu; Shao Ying Huang
Journal:  Tomography       Date:  2017-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.