| Literature DB >> 24595301 |
Zhiwei Wang1, Yu Chen1, Yining Wang1, Huadan Xue1, Zhengyu Jin1, Lingyan Kong1, Jian Cao1, Shuo Li1.
Abstract
PURPOSE: To evaluate the image quality and radiation dose of combined heart, head, and neck CT angiography (CTA) using prospectively electrocardiography (ECG)-triggered high-pitch spiral scan protocol, compared with single coronary CTA.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24595301 PMCID: PMC3940874 DOI: 10.1371/journal.pone.0090268
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Process of the patients’ enrollment.
Patient Characteristics for the Three Scanning Protocol Groups.
| Characteristics | Group1 | Group2 | Group3 | p |
| No. of patients | 47 | 51 | 53 | |
| No. of women | 20 | 23 | 24 | NS |
| Age (y) | 56.6±9.9 | 62.2±10.2 | 59.9±10.0 | NS |
| Heart rate (bpm) | 58.9±4.9 | 57.6±5.3 | 57.0±5.0 | NS |
| BMI (kg/m2) | 23.6±6.6 | 24.7±3.4 | 24.8±2.7 | NS |
NS = Not significant.
Comparison of Image Quality and Radiation Dose for Three Scanning Protocol Groups.
| Parameter | Group1 | Group2 | Group3 | P |
| Mean image quality of coronary arteries | 1.07±0.31 | 1.06±0.38 | 1.04±0.26 | 0.753 |
| SNR (AO) | 15.7±3.5 | 16.7±3.2 | 17.0±3.0 | 0.238 |
| SNR(LM) | 15.8±3.2 | 16.5±3.4 | 17.3±3.5 | 0.239 |
| SNR(RCA) | 15.6±3.3 | 16.7±3.2 | 17.4±3.4 | 0.100 |
| CNR(LM) | 17.9±3.6 | 19.2±4.3 | 20.3±4.3 | 0.073 |
| CNR(RCA) | 18.5±3.7 | 20.2±3.7 | 20.4±3.9 | 0.084 |
| CTDIvol (mGy) | 4.6±0.4 | 5.2±1.1 | 19.0±4.9 | <0.01 |
| DLP (mGy×cm) | 256.3±24.5 | 93.4±19.9 | 254.1±69.9 | <0.01 |
Note-Data are mean±SD. NS = Not significant, SNR = Signal-to-noise ratio, CNR = Contrast-to-noise ratio.
Figure 2Combined heart, neck and head arteries scan using prospectively ECG- triggered high-pitch spiral scan protocol for a 45-year-old male patient.
(a) VRT reconstruction of the whole arteries and MIP reconstructions of the coronary arteries of anterior descending(b) and carotid arteries (c), all with good opacification and definition, without artifacts. DLP was 242 mGy×cm (Scan time: 1.39s; Scan range: 538.5 cm; heart rate: 55 bpm; BMI: 25.4 kg/m2).
Figure 3Combined heart, neck and head arteries scan using prospectively ECG- triggered high-pitch spiral scan protocol for a 67-year-old female patient.
(a) MIP reconstruction of the coronary arteries revealed significant stenosis of proximal anterior descending and mild stenosis of proximal right coronary artery. (b)MIP reconstruction of left carotid arteries revealed calcification of proximal ICA. DLP was 242 mGy×cm (Scan time: 1.26s; Scan range: 490.0 cm; heart rate: 59 bpm; BMI: 23.1 kg/m2).