Literature DB >> 24567613

Very late perforation of an implantable cardioverter defibrillator lead: a case report.

Verena Semmler1, Stephanie Fichtner, Carsten Lennerz, Christof Kolb.   

Abstract

Entities:  

Mesh:

Year:  2014        PMID: 24567613      PMCID: PMC3905418          DOI: 10.3399/bjgp14X677329

Source DB:  PubMed          Journal:  Br J Gen Pract        ISSN: 0960-1643            Impact factor:   5.386


× No keyword cloud information.
  7 in total

Review 1.  Delayed lead perforation: a disturbing trend.

Authors:  Mohammed N Khan; George Joseph; Yaariv Khaykin; Khaled M Ziada; Bruce L Wilkoff
Journal:  Pacing Clin Electrophysiol       Date:  2005-03       Impact factor: 1.976

2.  Late right ventricular perforation after permanent pacemaker implantation: how far can the lead go?

Authors:  Ahmed Sanoussi; Badih El Nakadi; Ines Lardinois; Yasmine De Bruyne; Marc Joris
Journal:  Pacing Clin Electrophysiol       Date:  2005-07       Impact factor: 1.976

3.  Subacute cardiac perforations associated with active fixation leads.

Authors:  Maciej Sterliński; Andrzej Przybylski; Aleksander Maciag; Paweł Syska; Mariusz Pytkowski; Michał Lewandowski; Ilona Kowalik; Bohdan Firek; Piotr Kołsut; Grzegorz Religa; Mariusz Kuśmierczyk; Franciszek Walczak; Hanna Szwed
Journal:  Europace       Date:  2008-12-24       Impact factor: 5.214

4.  Prevalence and characterization of asymptomatic pacemaker and ICD lead perforation on CT.

Authors:  David A Hirschl; Vineet R Jain; Hugo Spindola-Franco; Jay N Gross; Linda B Haramati
Journal:  Pacing Clin Electrophysiol       Date:  2007-01       Impact factor: 1.976

5.  Incidence and predictors of cardiac perforation after permanent pacemaker placement.

Authors:  Srijoy Mahapatra; Kevin A Bybee; T Jared Bunch; Raul E Espinosa; Lawrence J Sinak; Michael D McGoon; David L Hayes
Journal:  Heart Rhythm       Date:  2005-09       Impact factor: 6.343

6.  Delayed lead perforation: can we ever let the guard down?

Authors:  Venkata M Alla; Yeruva M Reddy; William Abide; Tom Hee; Claire Hunter
Journal:  Cardiol Res Pract       Date:  2010-07-25       Impact factor: 1.866

7.  Delayed complications following pacemaker implantation.

Authors:  Kenneth A Ellenbogen; Mark A Wood; Richard K Shepard
Journal:  Pacing Clin Electrophysiol       Date:  2002-08       Impact factor: 1.976

  7 in total
  1 in total

1.  Very late perforation by a Riata implantable cardioverter-defibrillator lead-A case report.

Authors:  Masatsugu Nozoe; Kazuo Sakamoto; Daisuke Nagatomo; Nobuhiro Suematsu; Toru Kubota; Masanori Okabe; Yusuke Yamamoto
Journal:  J Arrhythm       Date:  2018-03-30
  1 in total