Literature DB >> 16171740

Incidence and predictors of cardiac perforation after permanent pacemaker placement.

Srijoy Mahapatra1, Kevin A Bybee, T Jared Bunch, Raul E Espinosa, Lawrence J Sinak, Michael D McGoon, David L Hayes.   

Abstract

BACKGROUND: Pericardial effusion, a sign of cardiac perforation, may complicate permanent pacemaker placement. Risk factors for development of post-permanent pacemaker effusion have not been evaluated.
OBJECTIVES: The purpose of this study was to determine the predictors of symptomatic pericardial effusion after permanent pacemaker placement.
METHODS: The Mayo Clinic pacemaker and echocardiogram databases were cross-referenced. From 1995 to 2003, 4,280 permanent pacemakers were implanted. Fifty (1.2%) patients developed significant effusion and symptoms consistent with perforation. They were randomly matched with 100 patients without effusion after permanent pacemaker placement.
RESULTS: The strongest predictors of postimplant effusion by univariate analysis were the concomitant use of a temporary transvenous pacemaker (hazard ratio [HR] 3.2, 95% confidence interval [CI] 1.6-6.2, P = .001) or steroid use within 7 days prior to implant (HR 4.1, 95% CI 1.1-10, P = .003). Weaker predictors were use of helical screw ventricular leads, body mass index (BMI) <20, older age, and longer fluoroscopy times. Variables associated with lower risk of perforation were right ventricular systolic pressure >35 mmHg (HR 0.70, 95% CI 0.44-0.97, P = .01) or BMI >30 (HR 0.62, 95% CI 0.41-0.93, P = .01). Multivariate predictors were use of temporary pacemaker (HR 2.7, 95% CI 1.4-3.9, P = .01), helical screw leads (HR 2.5; 95% CI 1.4-3.8, P = .04), and steroids (HR 3.2, 95% CI 1.1-5.4, P = .04). Right ventricular systolic pressure >35 mmHg was the only protective factor (HR 0.70, 95% CI 0.50-0.92, P = .02).
CONCLUSION: The incidence of postimplant effusions is low. In order to minimize periprocedural permanent pacemaker effusions, temporary pacemaker placement should be avoided unless essential, and particular care should be taken when placing a permanent pacemaker in patients who are taking steroids.

Entities:  

Mesh:

Year:  2005        PMID: 16171740     DOI: 10.1016/j.hrthm.2005.06.011

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  63 in total

1.  Delayed cardiac perforation due to migrating pacemaker lead.

Authors:  Anastasia Oikonomou; Soultana Foutzitzi; Panos Prassopoulos
Journal:  CMAJ       Date:  2010-04-19       Impact factor: 8.262

2.  Computational Optogenetics: A Novel Continuum Framework for the Photoelectrochemistry of Living Systems.

Authors:  Jonathan Wong; Oscar J Abilez; Ellen Kuhl
Journal:  J Mech Phys Solids       Date:  2012-06-01       Impact factor: 5.471

3.  Bleeding complications after pacemaker or cardioverter-defibrillator implantation in patients receiving dual antiplatelet therapy: Results of a prospective, two-centre registry.

Authors:  A Przybylski; P Derejko; W Kwaśniewski; D Urbańczyk-Swić; J Zakrzewska; W Orszulak; M Orczykowski; A Filipecki; L Szumowski; F Walczak; M Trusz-Gluza
Journal:  Neth Heart J       Date:  2010-05       Impact factor: 2.380

4.  Pneumomediastinum and right sided pneumothorax following dual chamber-ICD implantation.

Authors:  Jonathan Rosman; Michael D Shapiro; Sam Hanon
Journal:  J Interv Card Electrophysiol       Date:  2007-02-24       Impact factor: 1.900

Review 5.  [Strategies for the avoidance and treatment of complications during pacemaker implantation].

Authors:  C Kolb
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2007-12

6.  Pacemaker lead perforation causing hemopericardium eight years after implantation.

Authors:  Jackson J Liang; Ammar M Killu; Michael J Osborn; Allan S Jaffe
Journal:  Indian Heart J       Date:  2013-04-09

7.  Unusual chest pain syndromes caused by implanted cardiac device leads: a case series.

Authors:  Chance M Witt; Patricia J M Best; Samuel J Asirvatham; Christopher J McLeod
Journal:  J Interv Card Electrophysiol       Date:  2013-12-11       Impact factor: 1.900

Review 8.  State-of-the-art narrative review: multimodality imaging in electrophysiology and cardiac device therapies.

Authors:  Balint Laczay; Divyang Patel; Richard Grimm; Bo Xu
Journal:  Cardiovasc Diagn Ther       Date:  2021-06

9.  Acute right ventricular failure and pulseless electrical activity arrest following auto-transfusion of blood.

Authors:  Kolade M Agboola; John M Lasala; Marc A Sintek; Amit Noheria
Journal:  J Cardiol Cases       Date:  2018-01-12

10.  Loss of capture late after right ventricular pacing lead revision: what is the mechanism?

Authors:  Joachim Seegers; Lars Lüthje; Markus Zabel; Dirk Vollmann
Journal:  Clin Res Cardiol       Date:  2009-06-25       Impact factor: 5.460

View more