Literature DB >> 12358163

Delayed complications following pacemaker implantation.

Kenneth A Ellenbogen1, Mark A Wood, Richard K Shepard.   

Abstract

Acute complications resulting from permanent pacemaker implantation are well known and include perforation of the right atrium or right ventricle. Recently, several reports have described the occurrence of perforation and pericarditis as late complications following pacemaker implantation. These complications may occur days to weeks following uncomplicated pacemaker implantation and may lead to death if they are not recognized early. Five patients with late complications caused by active-fixation leads are reported and the clinical features of their presentation and management are reviewed. Late perforation of the right atrium or right ventricle is an uncommon complication after pacemaker implantation but should be suspected by the general cardiologist in a patient who has a device implanted within a week to several months prior to the development of chest pain.

Entities:  

Mesh:

Year:  2002        PMID: 12358163     DOI: 10.1046/j.1460-9592.2002.01155.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  31 in total

1.  What could be the cause of late syncope after pacemaker implantation?

Authors:  Mohammad Hossein Mandegar; Farideh Roshanali; Helia Farokhzad; Mahmood Eftekharzadeh
Journal:  BMJ Case Rep       Date:  2012-02-25

2.  Where is the pacemaker lead?

Authors:  Emilie Rulliat; Bernard Floccard; Alexandre Faure; Olivier Peguet; Roland Henaine; Jean Ninet; Bernard Allaouchiche
Journal:  Intensive Care Med       Date:  2010-07-07       Impact factor: 17.440

3.  Electrocardiographic algorithm for the diagnosis of inadvertent implantation of permanent pacemaker lead in the left ventricular cavity.

Authors:  Gustavo Goldenberg; Zaza Iakobishvili; Boris Strasberg
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-11-22       Impact factor: 1.468

Review 4.  Radiology of cardiac devices and their complications.

Authors:  J Dipoce; A Bernheim; H Spindola-Franco
Journal:  Br J Radiol       Date:  2014-11-20       Impact factor: 3.039

5.  Assessment of Cardiac Lead Perforation: Comparison Among Chest Radiography, Transthoracic Echocardiography and Electrocardiography-gated Contrast-enhanced Cardiac CT.

Authors:  Xiang Zhang; Chushan Zheng; Peiwei Wang; Dongye Wang; Boshui Huang; Guozhao Li; Huijun Hu; Zehong Yang; Xiaohui Duan; Shaoxin Zheng; Pinming Liu; Jingfeng Wang; Jun Shen
Journal:  Eur Radiol       Date:  2018-07-17       Impact factor: 5.315

Review 6.  State-of-the-art narrative review: multimodality imaging in electrophysiology and cardiac device therapies.

Authors:  Balint Laczay; Divyang Patel; Richard Grimm; Bo Xu
Journal:  Cardiovasc Diagn Ther       Date:  2021-06

7.  Successful management of late right ventricular perforation after pacemaker implantation.

Authors:  Amir K Bigdeli; Andres Beiras-Fernandez; Ingo Kaczmarek; Christian Kowalski; Michael Schmoeckel; Bruno Reichart
Journal:  Vasc Health Risk Manag       Date:  2010-02-04

8.  Delayed lead perforation: can we ever let the guard down?

Authors:  Venkata M Alla; Yeruva M Reddy; William Abide; Tom Hee; Claire Hunter
Journal:  Cardiol Res Pract       Date:  2010-07-25       Impact factor: 1.866

9.  Tale of a Wandering Lead: Late Atrial Lead Perforation into Right Lung following Pacemaker Implantation.

Authors:  Arjun Saradna; Ankur Sinha; Madina Abduraimova; Daniel Rodriguez; Felix Yang
Journal:  Cureus       Date:  2017-11-21

10.  Loss of capture late after right ventricular pacing lead revision: what is the mechanism?

Authors:  Joachim Seegers; Lars Lüthje; Markus Zabel; Dirk Vollmann
Journal:  Clin Res Cardiol       Date:  2009-06-25       Impact factor: 5.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.