Literature DB >> 20572143

High-resolution magnetization-prepared 3D-FLAIR imaging at 7.0 Tesla.

Fredy Visser1, Jaco J M Zwanenburg, Johannes M Hoogduin, Peter R Luijten.   

Abstract

The aim of the present study is to develop a submillimeter volumetric (three-dimensional) fluid-attenuated inversion recovery sequence at 7T. Implementation of the fluid-attenuated inversion recovery sequence is difficult as increased T(1) weighting from prolonged T(1) constants at 7T dominate the desired T(2) contrast and yield suboptimal signal-to-noise ratio. Magnetization preparation was used to reduce T(1) weighting and improve the T(2) weighting. Also, practical challenges limit the implementation. Long refocusing trains with low flip angles were used to mitigate the specific absorption rate constraints. This resulted in a three-dimensional magnetization preparation fluid-attenuated inversion recovery sequence with 0.8 x 0.8 x 0.8 = 0.5 mm(3) resolution in a clinically acceptable scan time. The contrast-to-noise ratio between gray matter and white matter (contrast-to-noise ratio = signal-to-noise ratio [gray matter] - signal-to-noise ratio [white matter]) increased from 12 +/- 9 without magnetization preparation to 28 +/- 8 with magnetization preparation (n = 12). The signal-to-noise ratio increased for white matter by 13 +/- 6% and for gray matter by 48 +/- 15%. In conclusion, three-dimensional fluid-attenuated inversion recovery with high resolution and full brain coverage is feasible at 7T. Magnetization preparation reduces the T(1) weighting, thereby improving the T(2) weighted contrast and signal-to-noise ratio. (c) 2010 Wiley-Liss, Inc.

Mesh:

Year:  2010        PMID: 20572143     DOI: 10.1002/mrm.22397

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  46 in total

1.  In vivo detection of cerebral cortical microinfarcts with high-resolution 7T MRI.

Authors:  Susanne J van Veluw; Jaco J M Zwanenburg; JooYeon Engelen-Lee; Wim G M Spliet; Jeroen Hendrikse; Peter R Luijten; Geert Jan Biessels
Journal:  J Cereb Blood Flow Metab       Date:  2012-12-19       Impact factor: 6.200

2.  Reduced scan time three-dimensional FLAIR using modulated inversion and repetition time.

Authors:  Neville D Gai; John A Butman
Journal:  J Magn Reson Imaging       Date:  2014-06-30       Impact factor: 4.813

3.  Optimization of magnetization-prepared 3-dimensional fluid attenuated inversion recovery imaging for lesion detection at 7 T.

Authors:  Manojkumar Saranathan; Thomas Tourdias; Adam B Kerr; Jeff D Bernstein; Geoffrey A Kerchner; May H Han; Brian K Rutt
Journal:  Invest Radiol       Date:  2014-05       Impact factor: 6.016

4.  3D T 2-weighted imaging at 7T using dynamic kT-points on single-transmit MRI systems.

Authors:  Florent Eggenschwiler; Kieran Robert O'Brien; Daniel Gallichan; Rolf Gruetter; José Pedro Marques
Journal:  MAGMA       Date:  2016-04-08       Impact factor: 2.310

5.  Quantitative T2 mapping using accelerated 3D stack-of-spiral gradient echo readout.

Authors:  Ruoxun Zi; Dan Zhu; Qin Qin
Journal:  Magn Reson Imaging       Date:  2020-08-27       Impact factor: 2.546

6.  Whole-brain three-dimensional T2-weighted BOLD functional magnetic resonance imaging at 7 Tesla.

Authors:  Jun Hua; Qin Qin; Peter C M van Zijl; James J Pekar; Craig K Jones
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

7.  Morphological features of MS lesions on FLAIR* at 7 T and their relation to patient characteristics.

Authors:  Iris D Kilsdonk; Alexandra Lopez-Soriano; Joost P A Kuijer; Wolter L de Graaf; Jonas A Castelijns; Chris H Polman; Peter R Luijten; Jeroen J J G Geurts; Frederik Barkhof; Mike P Wattjes
Journal:  J Neurol       Date:  2014-04-29       Impact factor: 4.849

8.  Slice-selective adiabatic magnetization T2 -preparation (SAMPA) for efficient T2 -weighted imaging at ultrahigh field strengths.

Authors:  Hadrien Dyvorne; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-12-01       Impact factor: 4.668

9.  Parallel reconstruction in accelerated multivoxel MR spectroscopy.

Authors:  V O Boer; D W J Klomp; J Laterra; P B Barker
Journal:  Magn Reson Med       Date:  2015-06-17       Impact factor: 4.668

10.  Multicontrast MR imaging at 7T in multiple sclerosis: highest lesion detection in cortical gray matter with 3D-FLAIR.

Authors:  I D Kilsdonk; W L de Graaf; A Lopez Soriano; J J Zwanenburg; F Visser; J P A Kuijer; J J G Geurts; P J W Pouwels; C H Polman; J A Castelijns; P R Luijten; F Barkhof; M P Wattjes
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-04       Impact factor: 3.825

View more