Literature DB >> 15648635

Low-voltage polymer-based scanning cantilever for in vivo optical coherence tomography.

Yuli Wang1, Mark Bachman, Guann-Pyng Li, Shuguang Guo, Brian J F Wong, Zhongping Chen.   

Abstract

Novel hand-held optical coherence tomography (OCT) probes with polymer cantilevers have been developed for clinical oral and skin imaging. An electroactive ionic polymer-metal composite cantilever was used to generate 3-mm transverse scanning movement of an optical fiber with applied 2-V linear alternating voltage at 1 Hz. Low driving voltage ensures safety. Two different optical designs achieve both forward and sidewise scanning and make it possible to image everywhere within the human oral cavity. In vivo OCT imaging of the human tongue is demonstrated.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15648635     DOI: 10.1364/ol.30.000053

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  7 in total

1.  Design of a handheld optical coherence microscopy endoscope.

Authors:  Vrushali R Korde; Erica Liebmann; Jennifer K Barton
Journal:  J Biomed Opt       Date:  2011-06       Impact factor: 3.170

2.  Compact piezoelectric transducer fiber scanning probe for optical coherence tomography.

Authors:  Ning Zhang; Tsung-Han Tsai; Osman O Ahsen; Kaicheng Liang; Hsiang-Chieh Lee; Ping Xue; Xingde Li; James G Fujimoto
Journal:  Opt Lett       Date:  2014-01-15       Impact factor: 3.776

3.  Intraoperative use of optical coherence tomography to differentiate normal and diseased thyroid and parathyroid tissues from lymph node and fat.

Authors:  Marc Rubinstein; Allison C Hu; Phil-Sang Chung; Jason H Kim; Kathryn E Osann; Paul Schalch; William B Armstrong; Brian J F Wong
Journal:  Lasers Med Sci       Date:  2020-04-27       Impact factor: 3.161

4.  Forward-viewing resonant fiber-optic scanning endoscope of appropriate scanning speed for 3D OCT imaging.

Authors:  Li Huo; Jiefeng Xi; Yicong Wu; Xingde Li
Journal:  Opt Express       Date:  2010-07-05       Impact factor: 3.894

5.  Semi-resonant operation of a fiber-cantilever piezotube scanner for stable optical coherence tomography endoscope imaging.

Authors:  Sucbei Moon; Sang-Won Lee; Marc Rubinstein; Brian J F Wong; Zhongping Chen
Journal:  Opt Express       Date:  2010-09-27       Impact factor: 3.894

6.  A forward-imaging needle-type OCT probe for image guided stereotactic procedures.

Authors:  Chia-Pin Liang; Jeremiah Wierwille; Thais Moreira; Gary Schwartzbauer; M Samir Jafri; Cha-Min Tang; Yu Chen
Journal:  Opt Express       Date:  2011-12-19       Impact factor: 3.894

7.  Intraoperative handheld optical coherence tomography forward-viewing probe: physical performance and preliminary animal imaging.

Authors:  Cuiru Sun; Kenneth K C Lee; Barry Vuong; Michael D Cusimano; Alexander Brukson; Antonio Mauro; Nigel Munce; Brian K Courtney; Beau A Standish; Victor X D Yang
Journal:  Biomed Opt Express       Date:  2012-05-16       Impact factor: 3.732

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.