Literature DB >> 24495437

Ultrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients: systematic review and meta-analysis.

Zhongheng Zhang1, Xiao Xu2, Sheng Ye3, Lei Xu4.   

Abstract

Respiratory variation in the inferior vena cava (ΔIVC) has been extensively studied with respect to its value in predicting fluid responsiveness, but the results are conflicting. This systematic review was aimed at investigating the diagnostic accuracy of ΔIVC in predicting fluid responsiveness. Databases including Medline, Embase, Scopus and Web of Knowledge were searched from inception to May 2013. Studies exploring the diagnostic performance of ΔIVC in predicting fluid responsiveness were included. To allow for more between- and within-study variance, a hierarchical summary receiver operating characteristic model was used to pool the results. Subgroup analyses were performed for patients on mechanical ventilation, spontaneously breathing patients and those challenged with colloids and crystalloids. A total of 8 studies involving 235 patients were eligible for analysis. Cutoff values of ΔIVC varied across studies, ranging from 12% to 40%. The pooled sensitivity and specificity in the overall population were 0.76 (95% confidence interval [CI]: 0.61-0.86) and 0.86 (95% CI: 0.69-0.95), respectively. The pooled diagnostic odds ratio (DOR) was 20.2 (95% CI: 6.1-67.1). The diagnostic performance of ΔIVC appeared to be better in patients on mechanical ventilation than in spontaneously breathing patients (DOR: 30.8 vs. 13.2). The pooled area under the receiver operating characteristic curve was 0.84 (95% CI: 0.79-0.89). Our study indicates that ΔIVC measured with point-of-care ultrasonography is of great value in predicting fluid responsiveness, particularly in patients on controlled mechanical ventilation and those resuscitated with colloids.
Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Critical illness; Fluid responsiveness; Mechanical ventilation; Meta-analysis; Ultrasonography; Variation in inferior vena cava

Mesh:

Substances:

Year:  2014        PMID: 24495437     DOI: 10.1016/j.ultrasmedbio.2013.12.010

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  61 in total

1.  Accuracy of the caval index and the expiratory diameter of the inferior vena cava for the diagnosis of dehydration in elderly.

Authors:  Daniele Orso; Nicola Guglielmo; Nicola Federici; Francesco Cugini; Alessio Ban; Filippo Mearelli; Roberto Copetti
Journal:  J Ultrasound       Date:  2016-04-08

2.  Fluid responsiveness raises many questions-echocardiography may be the answer.

Authors:  Chiara Lazzeri; Adriano Peris
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

3.  Ten situations where inferior vena cava ultrasound may fail to accurately predict fluid responsiveness: a physiologically based point of view.

Authors:  G Via; G Tavazzi; S Price
Journal:  Intensive Care Med       Date:  2016-04-23       Impact factor: 17.440

Review 4.  [Hemodynamic monitoring in intensive care and emergency medicine : Integration of clinical signs and ultrasound findings].

Authors:  D Hempel; R Pfister; G Michels
Journal:  Med Klin Intensivmed Notfmed       Date:  2016-06-09       Impact factor: 0.840

5.  Influence of breathing movements and Valsalva maneuver on vena caval dynamics.

Authors:  Alicia Laborda; Sergio Sierre; Mauro Malvè; Ignacio De Blas; Ignatios Ioakeim; William T Kuo; Miguel Angel De Gregorio
Journal:  World J Radiol       Date:  2014-10-28

6.  Limited value of end-expiratory inferior vena cava diameter to predict fluid responsiveness impact of intra-abdominal pressure.

Authors:  Antoine Vieillard-Baron; Bruno Evrard; Xavier Repessé; Julien Maizel; Christophe Jacob; Marine Goudelin; Cyril Charron; Gwenaël Prat; Michel Slama; Guillaume Geri; Philippe Vignon
Journal:  Intensive Care Med       Date:  2018-01-22       Impact factor: 17.440

Review 7.  [S3 guidelines on intensive medical care of cardiac surgery patients : Hemodynamic monitoring and cardiovascular system-an update].

Authors:  M Habicher; T Zajonz; M Heringlake; A Böning; S Treskatsch; U Schirmer; A Markewitz; M Sander
Journal:  Anaesthesist       Date:  2018-05       Impact factor: 1.041

Review 8.  Sepsis outside intensive care unit: the other side of the coin.

Authors:  F Mearelli; D Orso; N Fiotti; N Altamura; A Breglia; M De Nardo; I Paoli; M Zanetti; C Casarsa; G Biolo
Journal:  Infection       Date:  2014-08-11       Impact factor: 3.553

9.  Usefulness of inferior vena cava ultrasonography in outpatients with chronic heart failure.

Authors:  Jose Curbelo; Maria Aguilera; Pablo Rodriguez-Cortes; Paloma Gil-Martinez; Carmen Suarez Fernandez
Journal:  Clin Cardiol       Date:  2018-04-17       Impact factor: 2.882

Review 10.  Prediction of fluid responsiveness in ventilated patients.

Authors:  Mathieu Jozwiak; Xavier Monnet; Jean-Louis Teboul
Journal:  Ann Transl Med       Date:  2018-09
View more