Literature DB >> 25349666

Influence of breathing movements and Valsalva maneuver on vena caval dynamics.

Alicia Laborda1, Sergio Sierre1, Mauro Malvè1, Ignacio De Blas1, Ignatios Ioakeim1, William T Kuo1, Miguel Angel De Gregorio1.   

Abstract

AIM: To study changes produced within the inferior vena cava (IVC) during respiratory movements and identify their possible clinical implications.
METHODS: This study included 100 patients (46 women; 54 men) over 18 years of age who required an abdominal computed tomography (CT) and central venous access. IVC cross-sectional areas were measured on CT scans at three levels, suprarenal (SR), juxtarenal (JR) and infrarenal (IR), during neutral breathing and again during the Valsalva maneuver. All patients were instructed on how to perform a correct Valsalva maneuver. In order to reduce the total radiation dose in our patients, low-dose CT protocols were used in all patients. The venous blood pressure (systolic, diastolic and mean) was invasively measured at the same three levels with neutral breathing and the Valsalva maneuver during venous port implantation. From CT scans, three-dimensional models of the IVC were constructed and a collapsibility index was calculated for each patient. These data were then correlated with venous pressures and cross-sectional areas.
RESULTS: The mean patient age was 51.64 ± 12.01 years. The areas of the ellipse in neutral breathing were 394.49 ± 85.83 (SR), 380.10 ± 74.55 (JR), and 342.72 ± 49.77 mm(2) (IR), and 87.46 ± 18.35 (SR), 92.64 ± 15.36 (JR) and 70.05 ± 9.64 mm(2) (IR) during the Valsalva (Ps < 0.001). There was a correlation between areas in neutral breathing and in the Valsalva maneuver (P < 0.05 in all areas). Large areas decreased more than smaller areas. The collapsibility indices were 0.49 ± 0.06 (SR), 0.50 ± 0.04 (JR) and 0.50 ± 0.04 (IR), with no significant differences in any region. Reconstructed three-dimensional models showed a flattening of the IVC during Valsalva, adopting an ellipsoid cross-sectional shape. The mean pressures with neutral breathing were 9.44 ± 1.78 (SR), 9.40 ± 1.44 (JR) and 8.84 ± 1.03 mmHg (IR), and 81.08 ± 21.82 (SR), 79.88 ± 19.01 (JR) and 74.04 ± 16.56 mmHg (IR) during Valsalva (Ps < 0.001). There was a negative correlation between cross-sectional caval area and venous blood pressure, but this was not statistically significant in any of the cases. There was a significant correlation between diastolic and mean pressures measured during neutral breathing and in Valsalva.
CONCLUSION: Respiratory movements have a major influence on IVC dynamics. The increase in intracaval pressure during Valsalva results in a significant decrease in the IVC cross-sectional area.

Entities:  

Keywords:  Inferior vena cava; Morphology; Respiratory movements; Size; Valsalva; Venous hemodynamics

Year:  2014        PMID: 25349666      PMCID: PMC4209428          DOI: 10.4329/wjr.v6.i10.833

Source DB:  PubMed          Journal:  World J Radiol        ISSN: 1949-8470


  28 in total

1.  The effect of breathing manner on inferior vena caval diameter.

Authors:  Bruce J Kimura; Randy Dalugdugan; Glynn W Gilcrease; James N Phan; Brian K Showalter; Tanya Wolfson
Journal:  Eur J Echocardiogr       Date:  2010-10-27

2.  Volume associated dynamic geometry and spatial orientation of the inferior vena cava.

Authors:  Erin H Murphy; Frank R Arko; Clayton K Trimmer; Varinder S Phangureh; Thomas J Fogarty; Christopher K Zarins
Journal:  J Vasc Surg       Date:  2009-08-06       Impact factor: 4.268

Review 3.  Ultrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients: systematic review and meta-analysis.

Authors:  Zhongheng Zhang; Xiao Xu; Sheng Ye; Lei Xu
Journal:  Ultrasound Med Biol       Date:  2014-02-02       Impact factor: 2.998

4.  Biometry of infrarenal inferior vena cava measured by cavography. Clinical applications.

Authors:  P Bonnichon; F Gaudard; E Ouakil; P Lebozec; C de Labrouhe; A Bonnin; C Aaron; Y Chapuis
Journal:  Surg Radiol Anat       Date:  1989       Impact factor: 1.246

Review 5.  Normal inferior vena cava: caliber changes observed by dynamic ultrasound.

Authors:  E Grant; F Rendano; E Sevinc; J Gammelgaard; H H Holm; S Grønvall
Journal:  AJR Am J Roentgenol       Date:  1980-08       Impact factor: 3.959

6.  Ultrasonographic evaluation of ventilatory effect on inferior vena caval configuration.

Authors:  H Natori; S Tamaki; S Kira
Journal:  Am Rev Respir Dis       Date:  1979-08

7.  Inferior vena cava diameter and collapsibility index: a practical non-invasive evaluation of intravascular fluid volume in critically-ill patients.

Authors:  Prasert Thanakitcharu; Marisa Charoenwut; Napha Siriwiwatanakul
Journal:  J Med Assoc Thai       Date:  2013-03

8.  Evaluation of wall motion and dynamic geometry of the inferior vena cava using intravascular ultrasound: implications for future device design.

Authors:  Erin H Murphy; Eric D Johnson; Frank R Arko
Journal:  J Endovasc Ther       Date:  2008-06       Impact factor: 3.487

9.  Does ultrasonographic measurement of the inferior vena cava diameter correlate with central venous pressure in the assessment of intravascular volume in patients undergoing gastrointestinal surgery?

Authors:  Xiaobao Zhang; Hengfei Luan; Pin Zhu; Jiying Feng; Jizheng Cui; Zhibin Zhao
Journal:  J Surg Res       Date:  2014-05-01       Impact factor: 2.192

10.  Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients.

Authors:  Christophe Barbier; Yann Loubières; Christophe Schmit; Jan Hayon; Jean-Louis Ricôme; François Jardin; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2004-03-18       Impact factor: 17.440

View more
  7 in total

1.  Respiratory Phase Affects the Conspicuity of CSF-Venous Fistulas in Spontaneous Intracranial Hypotension.

Authors:  T J Amrhein; L Gray; M D Malinzak; P G Kranz
Journal:  AJNR Am J Neuroradiol       Date:  2020-07-16       Impact factor: 3.825

2.  Can the inferior vena cava collapsibility index be useful in predicting hypotension during spinal anaesthesia in a spontaneously breathing patient? A mini fluid challenge.

Authors:  Inna Jaremko; Asta Mačiulienė; Arūnas Gelmanas; Tautvydas Baranauskas; Ramūnas Tamošiūnas; Alfredas Smailys; Andrius Macas
Journal:  Acta Med Litu       Date:  2019

Review 3.  Focused Real-Time Ultrasonography for Nephrologists.

Authors:  Matthew J Kaptein; Elaine M Kaptein
Journal:  Int J Nephrol       Date:  2017-02-02

4.  Assessment of role of inferior vena cava collapsibility index and variations in carotid artery peak systolic velocity in prediction of post-spinal anaesthesia hypotension in spontaneously breathing patients: An observational study.

Authors:  Sumit R Chowdhury; Dalim K Baidya; Souvik Maitra; Akhil K Singh; Vimi Rewari; Rahul K Anand
Journal:  Indian J Anaesth       Date:  2022-02-24

5.  Intermittent endoleak via an aneurysm-iliac venous fistula after endovascular aneurysm repair.

Authors:  Yasuhiko Terai; Hiroshi Mitsuoka; Takahiro Ozawa
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-07-05

6.  Cauda equina movement during the Valsalva maneuver in two patients with Lumbar spinal canal stenosis.

Authors:  Ryo Yamakuni; Hironobu Ishikawa; Osamu Hasegawa; Hirofumi Sekino; Shiro Ishii; Koji Otani; Hiroshi Ito
Journal:  Fukushima J Med Sci       Date:  2022

7.  Measurements of Inferior Vena Cava Diameter for Prediction of Hypotension and Bradycardia during Spinal Anesthesia in Spontaneously Breathing Patients during Elective Knee Joint Replacement Surgery.

Authors:  Asta Mačiulienė; Arūnas Gelmanas; Inna Jaremko; Ramūnas Tamošiūnas; Alfredas Smailys; Andrius Macas
Journal:  Medicina (Kaunas)       Date:  2018-07-12       Impact factor: 2.430

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.