Literature DB >> 24474497

On the origins of chemical exchange saturation transfer (CEST) contrast in tumors at 9.4 T.

Junzhong Xu1, Moritz Zaiss, Zhongliang Zu, Hua Li, Jingping Xie, Daniel F Gochberg, Peter Bachert, John C Gore.   

Abstract

Chemical exchange saturation transfer (CEST) provides an indirect means to detect exchangeable protons within tissues through their effects on the water signal. Previous studies have suggested that amide proton transfer (APT) imaging, a specific form of CEST, detects endogenous amide protons with a resonance frequency offset 3.5 ppm downfield from water, and thus may be sensitive to variations in mobile proteins/peptides in tumors. However, as CEST measurements are influenced by various confounding effects, such as spillover saturation, magnetization transfer (MT) and MT asymmetry, the mechanism or degree of increased APT signal in tumors is not certain. In addition to APT, nuclear Overhauser enhancement (NOE) effects upfield from water may also provide distinct information on tissue composition. In the current study, APT, NOE and several other MR parameters were measured and compared comprehensively in order to elucidate the origins of APT and NOE contrasts in tumors at 9.4 T. In addition to conventional CEST methods, a new intrinsic inverse metric was applied to correct for relaxation and other effects. After corrections for spillover, MT and T1 effects, corrected APT in tumors was found not to be significantly different from that in normal tissues, but corrected NOE effects in tumors showed significant decreases compared with those in normal tissues. Biochemical measurements verified that there was no significant enhancement of protein contents in the tumors studied, consistent with the corrected APT measurements and previous literature, whereas quantitative MT data showed decreases in the fractions of immobile macromolecules in tumors. Our results may assist in the better understanding of the contrast depicted by CEST imaging in tumors, and in the development of improved APT and NOE measurements for cancer imaging.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  APT; AREX; CEST; NOE; exchange; protein concentration; relaxation

Mesh:

Substances:

Year:  2014        PMID: 24474497      PMCID: PMC3972041          DOI: 10.1002/nbm.3075

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  42 in total

1.  Quantitative imaging of magnetization transfer using an inversion recovery sequence.

Authors:  Daniel F Gochberg; John C Gore
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

2.  Protein extraction from solid tissue.

Authors:  Christer Ericsson; Monica Nistér
Journal:  Methods Mol Biol       Date:  2011

3.  Artifact reduction in EPI with phase-encoded reference scan.

Authors:  X Hu; T H Le
Journal:  Magn Reson Med       Date:  1996-07       Impact factor: 4.668

4.  An analysis of magnetic cross-relaxation between water and methylene protons in a model system.

Authors:  J C Gore; M S Brown; I M Armitage
Journal:  Magn Reson Med       Date:  1989-03       Impact factor: 4.668

5.  Separation of intramolecular NOE and exchange peaks in water exchange spectroscopy using spin-echo filters.

Authors:  S Mori; J M Berg; P C van Zijl
Journal:  J Biomol NMR       Date:  1996-01       Impact factor: 2.835

6.  Chemical exchange saturation transfer (CEST): what is in a name and what isn't?

Authors:  Peter C M van Zijl; Nirbhay N Yadav
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

7.  Optimized inversion recovery sequences for quantitative T1 and magnetization transfer imaging.

Authors:  Ke Li; Zhongliang Zu; Junzhong Xu; Vaibhav A Janve; John C Gore; Mark D Does; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

8.  Fast bound pool fraction imaging of the in vivo rat brain: association with myelin content and validation in the C6 glioma model.

Authors:  Hunter R Underhill; Robert C Rostomily; Andrei M Mikheev; Chun Yuan; Vasily L Yarnykh
Journal:  Neuroimage       Date:  2010-10-26       Impact factor: 6.556

9.  APT-weighted and NOE-weighted image contrasts in glioma with different RF saturation powers based on magnetization transfer ratio asymmetry analyses.

Authors:  Jinyuan Zhou; Xiaohua Hong; Xuna Zhao; Jia-Hong Gao; Jing Yuan
Journal:  Magn Reson Med       Date:  2013-05-09       Impact factor: 4.668

10.  Molecular imaging of proteins in tissues by mass spectrometry.

Authors:  Erin H Seeley; Richard M Caprioli
Journal:  Proc Natl Acad Sci U S A       Date:  2008-09-05       Impact factor: 11.205

View more
  64 in total

1.  Approximated analytical characterization of the steady-state chemical exchange saturation transfer (CEST) signals.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2019-06-24       Impact factor: 4.668

2.  Contributors to contrast between glioma and brain tissue in chemical exchange saturation transfer sensitive imaging at 3 Tesla.

Authors:  Rachel Scheidegger; Eric T Wong; David C Alsop
Journal:  Neuroimage       Date:  2014-05-20       Impact factor: 6.556

Review 3.  A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.

Authors:  Jinsuh Kim; Yin Wu; Yingkun Guo; Hairong Zheng; Phillip Zhe Sun
Journal:  Contrast Media Mol Imaging       Date:  2015-01-12       Impact factor: 3.161

4.  CEST MR-Fingerprinting: Practical considerations and insights for acquisition schedule design and improved reconstruction.

Authors:  Or Perlman; Kai Herz; Moritz Zaiss; Ouri Cohen; Matthew S Rosen; Christian T Farrar
Journal:  Magn Reson Med       Date:  2019-08-09       Impact factor: 4.668

5.  Chemical exchange saturation transfer fingerprinting for exchange rate quantification.

Authors:  Zhengwei Zhou; Pei Han; Bill Zhou; Anthony G Christodoulou; Jaime L Shaw; Zixin Deng; Debiao Li
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

6.  Quantitative assessment of amide proton transfer (APT) and nuclear overhauser enhancement (NOE) imaging with extrapolated semisolid magnetization transfer reference (EMR) signals: II. Comparison of three EMR models and application to human brain glioma at 3 Tesla.

Authors:  Hye-Young Heo; Yi Zhang; Shanshan Jiang; Dong-Hoon Lee; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2015-05-28       Impact factor: 4.668

7.  Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance fingerprinting (MRF).

Authors:  Ouri Cohen; Shuning Huang; Michael T McMahon; Matthew S Rosen; Christian T Farrar
Journal:  Magn Reson Med       Date:  2018-05-13       Impact factor: 4.668

8.  Observation of true and pseudo NOE signals using CEST-MRI and CEST-MRS sequences with and without lipid suppression.

Authors:  Jianhua Lu; Jinyuan Zhou; Congbo Cai; Shuhui Cai; Zhong Chen
Journal:  Magn Reson Med       Date:  2014-05-06       Impact factor: 4.668

9.  Imaging of amide proton transfer and nuclear Overhauser enhancement in ischemic stroke with corrections for competing effects.

Authors:  Hua Li; Zhongliang Zu; Moritz Zaiss; Imad S Khan; Robert J Singer; Daniel F Gochberg; Peter Bachert; John C Gore; Junzhong Xu
Journal:  NMR Biomed       Date:  2014-12-07       Impact factor: 4.044

10.  Relayed nuclear Overhauser enhancement sensitivity to membrane Cho phospholipids.

Authors:  Zhongliang Zu; Eugene C Lin; Elizabeth A Louie; Junzhong Xu; Hua Li; Jingping Xie; Christopher L Lankford; Eduard Y Chekmenev; Scott D Swanson; Mark D Does; John C Gore; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2020-04-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.