| Literature DB >> 24473714 |
Flávio Fernando Demarco1, Rudimar Antonio Baldissera1, Francine Cardozo Madruga1, Roberto Cuchiara Simões, Rafael Guerra Lund1, Marcos Britto Correa1, Maximiliano Sérgio Cenci1.
Abstract
OBJECTIVES: The aim of this study was to assess technical preferences of general dental practitioners when restoring anterior composite restorations. How the level of clinical experience or post-graduate training infuenced their options was also tested.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24473714 PMCID: PMC3891272 DOI: 10.1590/1679-775720130013
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Number of observations and frequencies of the studied variables among dentists (n=187)
|
|
|
|
| Type of composite | 169 | |
| Microhybrid | 83 | 52.2 (44.3-59.8) |
| Microfilled | 42 | 26.4 (20.1-34.0) |
| Nanohybrid | 26 | 16.4 (11.3-26.0) |
| Flow | 5 | 3.1 (1.0-6.8) |
| I don't know | 3 | 1.9 (0.4-5.1) |
| Type of adhesive | 161 | |
| 2-step total etch | 124 | 77.0 (70.4-83.8) |
| 3-step total etch | 25 | 15.5 (10.3-22.1) |
| 2-step self-etching | 5 | 3.1 (1.0-7.1) |
| 1-step self-etching (all-in-one) | 7 | 4.4 (1.8-8.8) |
| Type of light unit | 173 | |
| QTH | 43 | 24.86 (18.60-31.98) |
| LED | 126 | 72.83 (65.56-79.30) |
| Other | 4 | 2.3 (0.6-5.8) |
| Light Unit monitoring | 172 | |
| Monthly | 14 | 8.1 (4.5-13.3) |
| Semester | 31 | 18.0 (12.6-24.6) |
| Annual | 47 | 27.3 (20.8-34.6) |
| I don't know/I don't perform | 80 | 46.5 (38-9-54.3) |
| Time of polishing procedures | 164 | |
| Immediate | 123 | 75.0 (67.7-81.4) |
| 24 hours | 19 | 11.6 (7.1-17.5) |
| 7 days | 22 | 13.4 (8.6-19.6) |
| Type of polishing | 163 | |
| Ultrafine Diamond burs | 23 | 14.1 (9.2-20-4) |
| Flexible zinc aluminum oxide disks | 12 | 7.4 (3.9-12.5) |
| Silicon abrasive points | 27 | 16.6 (11.2-23.2) |
| Combination of materials | 101 | 62.0 (54.0-69.4) |
| Rubber dam usage | 187 | |
| No | 139 | 74.3 (67.5-80-4) |
| Yes | 48 | 25.7 (19.6-32.6) |
Number of valid observations.
QTH=quartz-tungsten halogen
LED=light-emitting diode
CI=Confidence Interval
Association between the time of clinical practice (since completing dental school) of dentists and variables related to practices for anterior composite restorations
|
| ||||||
|
|
|
|
|
|
| |
| Type of composite | 0.390 | |||||
| Microhybrid | 45 (58.4) | 17 (51.5) | 10 (50.0) | 11 (57.9) | 83 (55.7) | |
| Microfilled | 16 (20.8) | 10 (30.3) | 9 (45.0) | 5 (26.3) | 40 (26.8) | |
| Nanohybrid | 16 (20.8) | 6 (18.2) | 1 (5.0) | 3 (15.8) | 26 (17.5) | |
| Type of adhesive | 0.862 | |||||
| 2-step total etch | 63 (84.0) | 27 (87.1) | 19 (82.6) | 14 (77.8) | 123 (83.7) | |
| 3-step total etch | 12 (16.0) | 4 (12.9) | 4 (17.4) | 4 (22.2) | 24 (16.3) | |
| Type of light unit | 0.022 | |||||
| QTH | 14 (16.9) | 10 (28.6) | 8 (33.3) | 9 (36.0) | 41 (24.6) | |
| LED | 69 (83.3) | 25 (71.4) | 16 (66.7) | 16 (64.0) | 126 (75.5) | |
| Light Unit monitoring | <0.001 | |||||
| Yes | 32 (38.6) | 25 (67.6) | 14 (56.0) | 19 (76.0) | 90 (52.9) | |
| No | 51 (61.5) | 12 (32.4) | 11 (44.0) | 6 (24.0) | 80 (47.1) | |
| Time of polishing | 0.604 | |||||
| Immediate | 66 (80.5) | 23 (67.7) | 18 (78.3) | 16 (69.6) | 123 (75.9) | |
| After 24 h or latter | 16 (195) | 11 (32.4) | 5 (21.7) | 7 (30.4) | 39 (24.1) | |
| Type of polishing | 0.209 | |||||
| Ultrafine Diamond burs | 7 (8.9) | 5 (14.7) | 5 (21.7) | 6 (24.0) | 23 (14.3) | |
| Flexible zinc aluminum oxide disks | 5 (6.3) | 2 (5.9) | 3 (13.1) | 2 (8.0) | 12 (7.5) | |
| Silicon abrasive points | 19 (24.1) | 4 (11.8) | 1 (4.4) | 2 (8.0) | 26 (16.2) | |
| Combination of materials | 48 (60.8) | 23 (67.7) | 14 (60.9) | 15 (60.0) | 100 (62.1) | |
| Rubber dam usage | 0.012 | |||||
| No | 68 (81.0) | 25 (58.1) | 19 (67.9) | 26 (86.7) | 138 (74.6) | |
| Yes | 16 (19.1) | 18 (41.9) | 9 (32.1) | 4 (13.3) | 47 (25.4) | |
QTH=quartz-tungsten halogen
LED=light-emitting diode
Association between the post-graduation training of dentists and variables related to practices for anterior composite restorations
|
| ||||
|
|
|
|
| |
| Type of composite | 0.629 | |||
| Microhybrid | 35 (61.4) | 48 (53.9) | 83 (56.9) | |
| Microfilled | 15 (26.3) | 26 (29.2) | 41 (28.1) | |
| Nanohybrid | 7 (12.3) | 15 (16.9) | 22 (15.1) | |
| Type of adhesive | 0.040 | |||
| 2-step total etch | 52 (91.2) | 68 (78.2) | 120 (83.3) | |
| 3-step total etch | 5 (8.8) | 19 (21.8) | 24 (16.7) | |
| Type of light unit | 0.988 | |||
| QTH | 17 (26.2) | 26 (26.3) | 43 (26.2) | |
| LED | 48 (73.9) | 73 (73.7) | 121 (73.8) | |
| Light Unit monitoring | 0.014 | |||
| Yes | 26 (40.6) | 62 (60.2) | 88 (52.7) | |
| No | 38 (59.4) | 41 (39.8) | 79 (47.3) | |
| Time of polishing | 0.287 | |||
| Immediate | 50 (79.4) | 69 (71.9) | 119 (74.8) | |
| After 24 h or latter | 13 (20.6) | 27 (28.2) | 40 (25.2) | |
| Type of polishing | 0.588 | |||
| Ultrafine Diamond burs | 12 (19.1) | 11 (11.5) | 23 (14.5) | |
| Flexible zinc aluminum oxide disks | 4 (6.4) | 8 (8.3) | 12 (7.6) | |
| Silicon abrasive points | 10 (15.9) | 15 (15.6) | 25 (15.7) | |
| Combination of materials | 37 (58.7) | 62 (64.6) | 99 (62.3) | |
| Rubber dam usage | 0.044 | |||
| No | 55 (83.3) | 81 (69.8) | 136 (74.7) | |
| Yes | 11 (16.7) | 35 (30.2) | 46 (25.3) | |
QTH=quartz-tungsten halogen
LED=light-emitting diode