Thermal analysis of bulk filled composite resin polymerization using various light curing modes according to the curing depth and approximation to the cavity wall.

Hoon-Sang Chang1, Kyu-Jeong Cho, Su-Jung Park, Bin-Na Lee, Yun-Chan Hwang, Won-Mann Oh, In-Nam Hwang.   

Abstract

OBJECTIVE: The purpose of this study was to investigate the polymerization temperature of a bulk filled composite resin light-activated with various light curing modes using infrared thermography according to the curing depth and approximation to the cavity wall.
MATERIAL AND METHODS: Composite resin (AeliteFlo, Bisco, Schaumburg, IL, USA) was inserted into a Class II cavity prepared in the Teflon blocks and was cured with a LED light curing unit (Dr's Light, GoodDoctors Co., Seoul, Korea) using various light curing modes for 20 s. Polymerization temperature was measured with an infrared thermographic camera (Thermovision 900 SW/TE, Agema Infra-red Systems AB, Danderyd, Sweden) for 40 s at measurement spots adjacent to the cavity wall and in the middle of the cavity from the surface to a 4 mm depth. Data were analyzed according to the light curing modes with one-way ANOVA, and according to curing depth and approximation to the cavity wall with two-way ANOVA.
RESULTS: The peak polymerization temperature of the composite resin was not affected by the light curing modes. According to the curing depth, the peak polymerization temperature at the depth of 1 mm to 3 mm was significantly higher than that at the depth of 4 mm, and on the surface. The peak polymerization temperature of the spots in the middle of the cavity was higher than that measured in spots adjacent to the cavity wall.
CONCLUSION: In the photopolymerization of the composite resin, the temperature was higher in the middle of the cavity compared to the outer surface or at the internal walls of the prepared cavity.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24037066      PMCID: PMC3881899          DOI: 10.1590/1678-775720130036

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  29 in total

1.  Novel approach to measure composite conversion kinetics during exposure with stepped or continuous light-curing.

Authors:  F A Rueggeberg; W F Caughman; D C Chan
Journal:  J Esthet Dent       Date:  1999

2.  In vitro temperature change at the dentin/pulpal interface by using conventional visible light versus argon laser.

Authors:  D S Cobb; D N Dederich; T V Gardner
Journal:  Lasers Surg Med       Date:  2000       Impact factor: 4.025

3.  The effect of the pulse-delay cure technique on residual strain in composites.

Authors:  B I Suh; L Feng; Y Wang; C Cripe; F Cincione; W de Rjik
Journal:  Compend Contin Educ Dent       Date:  1999-02

4.  PULP RESPONSE TO EXTERNALLY APPLIED HEAT.

Authors:  L ZACH; G COHEN
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1965-04

5.  Effects of light curing modes and resin composites on temperature rise under human dentin: an in vitro study.

Authors:  Ihsan Hubbezoglu; Arife Dogan; Orhan Murat Dogan; Giray Bolayir; Bulent Bek
Journal:  Dent Mater J       Date:  2008-07       Impact factor: 2.102

6.  Temperature rise during polymerization of light-activated resin composites.

Authors:  A C Shortall; E Harrington
Journal:  J Oral Rehabil       Date:  1998-12       Impact factor: 3.837

7.  Physical properties and gap formation of light-cured composites with and without 'softstart-polymerization'.

Authors:  A Mehl; R Hickel; K H Kunzelmann
Journal:  J Dent       Date:  1997 May-Jul       Impact factor: 4.379

8.  Thermographic investigation of contemporary resin-containing dental materials.

Authors:  A A Al-Qudah; C A Mitchell; P A Biagioni; D L Hussey
Journal:  J Dent       Date:  2005-08       Impact factor: 4.379

9.  Thermographic measurement of temperature change during resin composite polymerization in vivo.

Authors:  D L Hussey; P A Biagioni; P J Lamey
Journal:  J Dent       Date:  1995-10       Impact factor: 4.379

10.  Effect of composite shade, increment thickness and curing light on temperature rise during photocuring.

Authors:  A A Al-Qudah; C A Mitchell; P A Biagioni; D L Hussey
Journal:  J Dent       Date:  2006-10-06       Impact factor: 4.379

View more
  7 in total

1.  Polymerization stress evolution of a bulk-fill flowable composite under different compliances.

Authors:  Yongwen Guo; Forrest A Landis; Zhengzhi Wang; Ding Bai; Li Jiang; Martin Y M Chiang
Journal:  Dent Mater       Date:  2016-02-06       Impact factor: 5.304

2.  Assessment of Heat Hazard during the Polymerization of Selected Light-Sensitive Dental Materials.

Authors:  Maciej Janeczek; Katarzyna Herman; Katarzyna Fita; Krzysztof Dudek; Małgorzata Kowalczyk-Zając; Agnieszka Czajczyńska-Waszkiewicz; Dagmara Piesiak-Pańczyszyn; Piotr Kosior; Maciej Dobrzyński
Journal:  Biomed Res Int       Date:  2016-10-20       Impact factor: 3.411

3.  Thermal rise during photopolymerization and degree of conversion of bulk fill and conventional resin composites.

Authors:  Sayed Mostafa Mousavinasab; Zahra Taromi; Elham Zajkani
Journal:  Dent Res J (Isfahan)       Date:  2020-08-14

Review 4.  Diagnosis of Temporomandibular Disorders Using Thermovision Imaging.

Authors:  Monika Machoy; Liliana Szyszka-Sommerfeld; Mansur Rahnama; Robert Koprowski; Sławomir Wilczyński; Krzysztof Woźniak
Journal:  Pain Res Manag       Date:  2020-11-17       Impact factor: 3.037

5.  Real-Time Analysis of Temperature Changes in Composite Increments and Pulp Chamber during Photopolymerization.

Authors:  Ryan Jin-Young Kim; In-Bog Lee; Jin-Young Yoo; Su-Jung Park; Sin-Young Kim; Young-Ah Yi; Ji-Yun Hwang; Deog-Gyu Seo
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411

6.  Anterior composite restorations in clinical practice: findings from a survey with general dental practitioners.

Authors:  Flávio Fernando Demarco; Rudimar Antonio Baldissera; Francine Cardozo Madruga; Roberto Cuchiara Simões; Rafael Guerra Lund; Marcos Britto Correa; Maximiliano Sérgio Cenci
Journal:  J Appl Oral Sci       Date:  2013 Nov-Dec       Impact factor: 2.698

7.  Plugger temperature of cordless heat carriers according to the time elapsed.

Authors:  Hoon-Sang Chang; Se-Hee Park; Kyung-Mo Cho; Jin-Woo Kim
Journal:  Restor Dent Endod       Date:  2018-02-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.