OBJECTIVES: The objectives of this study were to acquire ultra-high resolution images of the brain using balanced steady-state free precession (bSSFP) at 7 T and to identify the potential utility of this sequence. MATERIALS AND METHODS: Eight volunteers participated in this study after providing informed consent. Each volunteer was scanned with 8 phase cycles of bSSFP at 0.4-mm isotropic resolution using 0.5 number of excitations and 2-dimensional parallel acceleration of 1.75 × 1.75. Each phase cycle required 5 minutes of scanning, with pauses between the phase cycles allowing short periods of rest. The individual phase cycles were aligned and then averaged. The same volunteers underwent scanning using 3-dimensional (3D) multiecho gradient recalled echo at 0.8-mm isotropic resolution, 3D Cube T2 at 0.7-mm isotropic resolution, and thin-section coronal oblique T2-weighted fast spin echo at 0.22 × 0.22 × 2.0-mm resolution for comparison. Two neuroradiologists assessed image quality and potential research and clinical utility. RESULTS: The volunteers generally tolerated the scan sessions well, and composite high-resolution bSSFP images were produced for each volunteer. Rater analysis demonstrated that bSSFP had a superior 3D visualization of the microarchitecture of the hippocampus, very good contrast to delineate the borders of the subthalamic nucleus, and relatively good B1 homogeneity throughout. In addition to an excellent visualization of the cerebellum, subtle details of the brain and skull base anatomy were also easier to identify on the bSSFP images, including the line of Gennari, membrane of Liliequist, and cranial nerves. Balanced steady-state free precession had a strong iron contrast similar to or better than the comparison sequences. However, cortical gray-white contrast was significantly better with Cube T2 and T2-weighted fast spin echo. CONCLUSIONS: Balanced steady-state free precession can facilitate ultrahigh-resolution imaging of the brain. Although total imaging times are long, the individually short phase cycles can be acquired separately, improving examination tolerability. These images may be beneficial for studies of the hippocampus, iron-containing structures such as the subthalamic nucleus and line of Gennari, and the basal cisterns and their contents.
OBJECTIVES: The objectives of this study were to acquire ultra-high resolution images of the brain using balanced steady-state free precession (bSSFP) at 7 T and to identify the potential utility of this sequence. MATERIALS AND METHODS: Eight volunteers participated in this study after providing informed consent. Each volunteer was scanned with 8 phase cycles of bSSFP at 0.4-mm isotropic resolution using 0.5 number of excitations and 2-dimensional parallel acceleration of 1.75 × 1.75. Each phase cycle required 5 minutes of scanning, with pauses between the phase cycles allowing short periods of rest. The individual phase cycles were aligned and then averaged. The same volunteers underwent scanning using 3-dimensional (3D) multiecho gradient recalled echo at 0.8-mm isotropic resolution, 3D Cube T2 at 0.7-mm isotropic resolution, and thin-section coronal oblique T2-weighted fast spin echo at 0.22 × 0.22 × 2.0-mm resolution for comparison. Two neuroradiologists assessed image quality and potential research and clinical utility. RESULTS: The volunteers generally tolerated the scan sessions well, and composite high-resolution bSSFP images were produced for each volunteer. Rater analysis demonstrated that bSSFP had a superior 3D visualization of the microarchitecture of the hippocampus, very good contrast to delineate the borders of the subthalamic nucleus, and relatively good B1 homogeneity throughout. In addition to an excellent visualization of the cerebellum, subtle details of the brain and skull base anatomy were also easier to identify on the bSSFP images, including the line of Gennari, membrane of Liliequist, and cranial nerves. Balanced steady-state free precession had a strong iron contrast similar to or better than the comparison sequences. However, cortical gray-white contrast was significantly better with Cube T2 and T2-weighted fast spin echo. CONCLUSIONS: Balanced steady-state free precession can facilitate ultrahigh-resolution imaging of the brain. Although total imaging times are long, the individually short phase cycles can be acquired separately, improving examination tolerability. These images may be beneficial for studies of the hippocampus, iron-containing structures such as the subthalamic nucleus and line of Gennari, and the basal cisterns and their contents.
Authors: E C Bourekas; G A Christoforidis; A M Abduljalil; A Kangarlu; D W Chakeres; D G Spigos; P M Robitaille Journal: J Comput Assist Tomogr Date: 1999 Nov-Dec Impact factor: 1.826
Authors: Phillip DiGiacomo; Julian Maclaren; Murat Aksoy; Elizabeth Tong; Mackenzie Carlson; Bryan Lanzman; Syed Hashmi; Ronald Watkins; Jarrett Rosenberg; Brian Burns; Timothy W Skloss; Dan Rettmann; Brian Rutt; Roland Bammer; Michael Zeineh Journal: Magn Reson Med Date: 2020-02-20 Impact factor: 4.668
Authors: Michael M Zeineh; Nicola Palomero-Gallagher; Markus Axer; David Gräßel; Maged Goubran; Andreas Wree; Roger Woods; Katrin Amunts; Karl Zilles Journal: Cereb Cortex Date: 2017-03-01 Impact factor: 5.357
Authors: Thomas F Barrett; Hadrien A Dyvorne; Francesco Padormo; Puneet S Pawha; Bradley N Delman; Raj K Shrivastava; Priti Balchandani Journal: World Neurosurg Date: 2017-03-27 Impact factor: 2.104
Authors: Nanthia A Suthana; Markus Donix; David R Wozny; Adam Bazih; Michael Jones; Robin M Heidemann; Robert Trampel; Arne D Ekstrom; Maria Scharf; Barbara Knowlton; Robert Turner; Susan Y Bookheimer Journal: J Cogn Neurosci Date: 2014-12-16 Impact factor: 3.225
Authors: Timothy M Shepherd; Michael J Hoch; Mary Bruno; Arline Faustin; Antonios Papaioannou; Stephen E Jones; Orrin Devinsky; Thomas Wisniewski Journal: Front Neuroanat Date: 2020-03-19 Impact factor: 3.856