Literature DB >> 24460748

A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template.

Marjolein Vercruyssen1, Catherine Cox, Wim Coucke, Ignace Naert, Reinhilde Jacobs, Marc Quirynen.   

Abstract

AIM: To assess the accuracy of guided surgery (mucosa and bone-supported) compared to mental navigation or the use of a surgical template, in fully edentulous jaws, in a randomized controlled study.
MATERIAL AND METHODS: Fifty-nine patients (72 jaws), requiring four to six implants (maxilla or mandible), were consecutively recruited and randomly assigned to one of the following treatment groups; guidance via Materialise Universal(®)/mucosa, Materialise Universal(®)/bone, Facilitate™/mucosa, Facilitate™/bone, or mental navigation or a pilot-drill template. The precision was assessed by matching the planning computed tomography (CT) with a post-operative cone beam CT.
RESULTS: A significant lower mean deviation at the entry point (1.4 mm, range: 0.3-3.7), at the apex (1.6 mm, range: 0.2-3.7) and angular deviation (3.0°, range: 0.2-16°) was observed for the guiding systems when compared to mental navigation (2.7 mm, range: 0.3-8.3; 2.9 mm, range: 0.5-7.4 and 9.9°, range: 1.5-27.8) and to the surgical template group (3.0 mm, range: 0.6-6.6; 3.4 mm, range: 0.3-7.5 and 8.4°, range: 0.6-21.3°). Differences between bone and mucosa support or type of guidance were negligible. Jaw and implant location (posterior-anterior, left-right), however, had a significant influence on the accuracy when guided.
CONCLUSION: Based on these findings, guided implant placement appears to offer clear accuracy benefits.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  accuracy; dental implant; stereolitography; surgical template; three-dimensional imaging

Mesh:

Substances:

Year:  2014        PMID: 24460748     DOI: 10.1111/jcpe.12231

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  22 in total

1.  A novel workflow for computer guided implant surgery matching digital dental casts and CBCT scan.

Authors:  G DE Vico; F Ferraris; L Arcuri; F Guzzo; D Spinelli
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

2.  Reproducibility of CBCT image analysis: a clinical study on intrapersonal and interpersonal errors in bone structure determination.

Authors:  Sigmar Schnutenhaus; Michael Graf; Isabel Doering; Ralph G Luthardt; Heike Rudolph
Journal:  Oral Radiol       Date:  2018-07-27       Impact factor: 1.852

3.  3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph; Jens Dreyhaupt; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-01-22       Impact factor: 3.573

4.  [Research advances in the use of digital surgical guides in implantology].

Authors:  Xiao-Hua Wang; Ai-Peng Liu; Wen-Zheng Deng
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01

5.  [Precise investigation of digital guide plates applied to implant surgery of anterior teeth].

Authors:  Fang-Zhi Lou; Mao-Rui Zhang; Peng-Cheng Rao; Shi-Hong Luo; Meng-Ying Tang; Jin-Gang Xiao
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-04-01

Review 6.  Clinical efficacy and effectiveness of 3D printing: a systematic review.

Authors:  Laura E Diment; Mark S Thompson; Jeroen H M Bergmann
Journal:  BMJ Open       Date:  2017-12-21       Impact factor: 2.692

7.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

Review 8.  Indications for 3-D diagnostics and navigation in dental implantology with the focus on radiation exposure: a systematic review.

Authors:  Burkhard Kunzendorf; Hendrik Naujokat; Jörg Wiltfang
Journal:  Int J Implant Dent       Date:  2021-05-27

9.  Factors Influencing the Accuracy of Freehand Implant Placement: A Prospective Clinical Study.

Authors:  Sigmar Schnutenhaus; Marie Wagner; Cornelia Edelmann; Ralph G Luthardt; Heike Rudolph
Journal:  Dent J (Basel)       Date:  2021-05-10

10.  Registration of cone beam computed tomography data and intraoral surface scans - A prerequisite for guided implant surgery with CAD/CAM drilling guides.

Authors:  Tabea Flügge; Wiebe Derksen; Jobine Te Poel; Bassam Hassan; Katja Nelson; Daniel Wismeijer
Journal:  Clin Oral Implants Res       Date:  2016-07-20       Impact factor: 5.977

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.