Transfemoral sockets with vacuum-assisted suspension comparison of hip kinematics, socket position, contact pressure, and preference: ischial containment versus brimless.

Jason T Kahle1, M Jason Highsmith.   

Abstract

The objective of this study was to investigate the effect of brimless compared with ischial ramus containment (IRC) prosthetic sockets when using vacuum-assisted suspension (VAS) on persons with a unilateral transfemoral amputation (TFA). A randomized crossover design with a 2 d accommodation was used. People with unilateral TFA (n = 9 analyzed) were enrolled. Interventions were IRC VAS and brimless VAS sockets. Main outcome measures included coronal hip angle and vertical and lateral socket movement as measured by X-ray, skin pressure measured by Tekscan, and preference measured subjectively. The brimless design was statistically equivalent to IRC in all measured coronal hip angles and vertical and lateral socket displacement. The peak/stance mean pressure in the medial proximal aspect of the socket was 322 mmHg in the IRC compared with 190 mmHg in the brimless condition. Except for medial proximal pressure, no other measures reached statistical significance. All subjects reported the brimless design to be more comfortable than the IRC in short-term preference. Brimless VAS socket design may be a clinically viable choice for people with TFA.

Entities:  

Keywords:  X-ray; amputation; biomechanics; fluoroscope; ischial zzm321990ramus containment; kinematics; prosthetic; suspension; transfemoral socket; vacuum-assisted suspension

Mesh:

Year:  2013        PMID: 24458964     DOI: 10.1682/JRRD.2013.01.0003

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  10 in total

1.  Evaluation of Force Sensing Resistors for the Measurement of Interface Pressures in Lower Limb Prosthetics.

Authors:  Eric Swanson; Ethan Weathersby; John Cagle; Joan E Sanders
Journal:  J Biomech Eng       Date:  2019-04-24       Impact factor: 2.097

2.  RADIOGRAPHIC ASSESSMENT OF EXTREMITY OSSEOINTEGRATION FOR THE AMPUTEE.

Authors:  Munjed Al Muderis; Belinda A Bosley; Anthony V Florschutz; Paul A Lunseth; Tyler D Klenow; M Jason Highsmith; Jason T Kahle
Journal:  Technol Innov       Date:  2016-09

3.  COMPARATIVE EFFECTIVENESS OF AN ADJUSTABLE TRANSFEMORAL PROSTHETIC INTERFACE ACCOMMODATING VOLUME FLUCTUATION: CASE STUDY.

Authors:  Jason T Kahle; Tyler D Klenow; M Jason Highsmith
Journal:  Technol Innov       Date:  2016-09

4.  THE EFFECT OF TRANSFEMORAL INTERFACE DESIGN ON GAIT SPEED AND RISK OF FALLS.

Authors:  Jason T Kahle; Tyler D Klenow; William J Sampson; M Jason Highsmith
Journal:  Technol Innov       Date:  2016-09

5.  Evaluation of a Prototype Hybrid Vacuum Pump to Provide Vacuum-Assisted Suspension for Above-Knee Prostheses.

Authors:  Matthew J Major; Ryan Caldwell; Stefania Fatone
Journal:  J Med Device       Date:  2015-08-06       Impact factor: 0.582

6.  Two case reports showing a rather striking abnormal finding of unknown origin localized to the cortex of an amputated femur.

Authors:  Masafumi Sakai; Hirotaka Mutsuzaki; Yukiyo Shimizu; Yoshikazu Okamoto; Takahito Nakajima
Journal:  Radiol Case Rep       Date:  2022-10-12

7.  Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation: Part 2 Description and Preliminary evaluation.

Authors:  Stefania Fatone; Ryan Caldwell
Journal:  Prosthet Orthot Int       Date:  2017-01-30       Impact factor: 1.895

8.  Within-subject effects of standardized prosthetic socket modifications on physical function and patient-reported outcomes.

Authors:  William Anderst; Goeran Fiedler; Kentaro Onishi; Gina McKernan; Tom Gale; Paige Paulus
Journal:  Trials       Date:  2022-04-12       Impact factor: 2.279

9.  Characterization of interfacial socket pressure in transhumeral prostheses: A case series.

Authors:  Jonathon S Schofield; Katherine R Schoepp; Heather E Williams; Jason P Carey; Paul D Marasco; Jacqueline S Hebert
Journal:  PLoS One       Date:  2017-06-02       Impact factor: 3.240

10.  Comparing Gait with Multiple Physical Asymmetries Using Consolidated Metrics.

Authors:  Tyagi Ramakrishnan; Christina-Anne Lahiff; Kyle B Reed
Journal:  Front Neurorobot       Date:  2018-02-13       Impact factor: 2.650

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.