Signal and contrast effects due to T2 decay during k-space readout of UTE (ultrashort TE) sequences.

Jing-Tzyh Alan Chiang1, Michael Carl2, Jiang Du2.   

Abstract

In ultrashort TE (UTE) imaging, the short T2 values of the tissues of interest are comparable to the k-space readout duration, which result in significant T2 decay during k-space readout. This decay consequently causes significant effects on signal and contrast in UTE sequences, which we evaluate in this paper using models that incorporate the gradient slew rate slew and maximal constant gradient strength gmax, in conjunction with objects of diameter L. The resulting signal and contrast relationships demonstrate steep signal changes between T2 values of ~50-500μs, corresponding to high T2 weighted contrast in this range. When γ⋅gmax(2)/(4π⋅slew)>1/(2L), termed the "ramp only" regime, gmax has no significant effect whereas decreasing slew leads to decreases in signal amplitude and shifts the contrast peak to higher T2 values. When γ⋅gmax(2)/(4π⋅slew)<1/(2L), termed the "mixed gradient" regime, both gmax and slew have significant effects, where decreases in either gmax or slew lead to lower signal amplitudes and shifts the contrast peak to higher T2 values. Under typical scan settings, the "ramp only" regime is usually dominant. Further, we demonstrate an unusual dependence of T2 weighted signal and contrast on object size, whereby objects with smaller values of L demonstrate lower signal amplitudes and peak contrast at higher T2 values, compared to otherwise identical objects with larger L. These results improve understanding of T2 weighted signal and contrast properties in short T2 tissue imaging with UTE.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  UTE; Ultrashort TE

Mesh:

Year:  2013        PMID: 24457160      PMCID: PMC4118680          DOI: 10.1016/j.mri.2013.11.002

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  13 in total

1.  The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI.

Authors:  R T Constable; J C Gore
Journal:  Magn Reson Med       Date:  1992-11       Impact factor: 4.668

2.  Optimization of RF excitation to maximize signal and T2 contrast of tissues with rapid transverse relaxation.

Authors:  Michael Carl; Mark Bydder; Jiang Du; Atsushi Takahashi; Eric Han
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

3.  Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone.

Authors:  Jiang Du; Michael Carl; Mark Bydder; Atsushi Takahashi; Christine B Chung; Graeme M Bydder
Journal:  J Magn Reson       Date:  2010-09-25       Impact factor: 2.229

Review 4.  Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: technical considerations.

Authors:  Damian J Tyler; Matthew D Robson; R Mark Henkelman; Ian R Young; Graeme M Bydder
Journal:  J Magn Reson Imaging       Date:  2007-02       Impact factor: 4.813

5.  Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling.

Authors:  Jürgen Rahmer; Peter Börnert; Jan Groen; Clemens Bos
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

6.  MRI with zero echo time: hard versus sweep pulse excitation.

Authors:  Markus Weiger; Klaas P Pruessmann; Franciszek Hennel
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

7.  Point spread functions of the T2 decay in k-space trajectories with long echo train.

Authors:  Qin Qin
Journal:  Magn Reson Imaging       Date:  2012-07-18       Impact factor: 2.546

8.  Bone matrix imaged in vivo by water- and fat-suppressed proton projection MRI (WASPI) of animal and human subjects.

Authors:  Yaotang Wu; Mirko I Hrovat; Jerome L Ackerman; Timothy G Reese; Haihui Cao; Kirsten Ecklund; Melvin J Glimcher
Journal:  J Magn Reson Imaging       Date:  2010-04       Impact factor: 4.813

9.  Cortical bone water: in vivo quantification with ultrashort echo-time MR imaging.

Authors:  Aranee Techawiboonwong; Hee Kwon Song; Mary B Leonard; Felix W Wehrli
Journal:  Radiology       Date:  2008-07-15       Impact factor: 11.105

10.  Fast and quiet MRI using a swept radiofrequency.

Authors:  Djaudat Idiyatullin; Curt Corum; Jang-Yeon Park; Michael Garwood
Journal:  J Magn Reson       Date:  2006-06-19       Impact factor: 2.229

View more
  1 in total

Review 1.  MRI assessment of bone structure and microarchitecture.

Authors:  Gregory Chang; Sean Boone; Dimitri Martel; Chamith S Rajapakse; Robert S Hallyburton; Mitch Valko; Stephen Honig; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2017-02-06       Impact factor: 4.813

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.