Literature DB >> 24431743

An evaluation of dimensional accuracy of one-step and two-step impression technique using addition silicone impression material: an in vitro study.

Neelam A Pande1, R D Parkhedkar2.   

Abstract

The study is aimed to evaluate the dimensional accuracy, the effect of undercut of two different configurations and the elastic recovery of addition silicone impression material assessed indirectly, by measuring the dimensions on stone models recorded from the impression of the master model, using one-step and two-step impression technique, for addition silicone impression materials. Measurements are taken to evaluate horizontal or linear and vertical dimensional changes, of the abutment V and abutment C from the stainless steel model. Heavy body/light body material is used for making one-step impression technique in a custom tray. Putty/light body is used for taking two-step technique in a stock metal tray. Improved die stone is used for pouring the impression. The different 11 locations on the dies produced by two different techniques are measured microscopically on image analyzer and compared with those of stainless steel model. Anova test was applied to test the differences of mean values of inter and intra abutment measurements, to calculate p value. Unpaired t test was applied to calculate t value. Results showed less deviation of stone models produced by one-step technique from stainless steel model, whereas the deviation of stone models produced by two-step is comparatively more. (p < 0.01). This difference of deviation is significantly less in one-step as compared to two-step technique. One-step is sufficiently dimensionally accurate than two-step technique in conjunction with addition silicone impression material. They have the best elastic recovery from the two undercut configurations.

Entities:  

Keywords:  Dimensional accuracy; Elastomeric impression materials; One-step impression technique; Two-step impression technique

Year:  2012        PMID: 24431743      PMCID: PMC3732700          DOI: 10.1007/s13191-012-0182-1

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  9 in total

1.  Accuracy of one-step versus two-step putty wash addition silicone impression technique.

Authors:  S H Hung; J H Purk; D E Tira; J D Eick
Journal:  J Prosthet Dent       Date:  1992-05       Impact factor: 3.426

2.  Adhesive properties of several impression material systems: Part II.

Authors:  J Y Chai; L M Jameson; J B Moser; R A Hesby
Journal:  J Prosthet Dent       Date:  1991-09       Impact factor: 3.426

3.  Accuracy and dimensional stability of elastomeric impression materials.

Authors:  W B Eames; S W Wallace; N B Suway; L B Rogers
Journal:  J Prosthet Dent       Date:  1979-08       Impact factor: 3.426

4.  Evaluation of a rubber-base impression material.

Authors:  G Gunther; S I Welsh
Journal:  J Prosthet Dent       Date:  1978-01       Impact factor: 3.426

5.  Effect of material bulk and undercuts on the accuracy of impression materials.

Authors:  P A de Araujo; K D Jorgensen
Journal:  J Prosthet Dent       Date:  1985-12       Impact factor: 3.426

6.  Custom impression trays: Part I--Mechanical properties.

Authors:  L C Breeding; D L Dixon; J P Moseley
Journal:  J Prosthet Dent       Date:  1994-01       Impact factor: 3.426

7.  Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models.

Authors:  G H Johnson; R G Craig
Journal:  J Prosthet Dent       Date:  1985-04       Impact factor: 3.426

8.  Accuracy of addition silicones as a function of technique.

Authors:  G H Johnson; R G Craig
Journal:  J Prosthet Dent       Date:  1986-02       Impact factor: 3.426

9.  Comparison of elastomeric impression materials used in fixed prosthodontics.

Authors:  J N Ciesco; W F Malone; J L Sandrik; B Mazur
Journal:  J Prosthet Dent       Date:  1981-01       Impact factor: 3.426

  9 in total
  1 in total

1.  Effect of Core Materials on the Dimensional Accuracy of Casts Made of Two Different Silicone Impression Materials: An Experimental Study.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Mohammad-Hassan Kalantari
Journal:  J Int Soc Prev Community Dent       Date:  2020-03-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.