Literature DB >> 3889281

Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models.

G H Johnson, R G Craig.   

Abstract

The accuracy of four types of elastomeric impression materials was studied as a function of model location, time of pouring, and repetition of pouring. There was little change in dimension among abutment preparations for all materials, for all times of pour, and with a repeat pouring. It appears that measurements between posts are not sensitive to detecting differences between materials and that other dimensions should be examined to discern where differences might lie. The diameter of the stone post was larger than the standard for the AS and PS materials and was unchanged or smaller than the standard for the CS and the PE. The vertical dimensions of stone posts were, in general, shorter than the standard for all materials, with the AS demonstrating the smallest change. The AS and CS products demonstrated the best recovery from undercuts and the least change in dimensions between an initial and second pour of an impression. The AS and PE were the least affected with delays of 1, 4, and 24 hours in pouring the impression.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3889281     DOI: 10.1016/0022-3913(85)90630-4

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  23 in total

1.  A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material.

Authors:  Smita Sara Manoj; K P Cherian; Vidya Chitre; Meena Aras
Journal:  J Indian Prosthodont Soc       Date:  2013-02-06

2.  An evaluation of dimensional accuracy of one-step and two-step impression technique using addition silicone impression material: an in vitro study.

Authors:  Neelam A Pande; R D Parkhedkar
Journal:  J Indian Prosthodont Soc       Date:  2012-10-10

3.  A Comparative Evaluation of Accuracy of the Dies Affected by Tray Type, Material Viscosity, and Pouring Sequence of Dual and Single Arch Impressions- An In vitro Study.

Authors:  Poonam R Kulkarni; Rahul S Kulkarni; Rupal J Shah; Rahul Chhajlani; Bhuwan Saklecha; Kavita Maru
Journal:  J Clin Diagn Res       Date:  2017-04-01

4.  Digital work-flow.

Authors:  V Marsango; R Bollero; N D'Ovidio; M Miranda; P Bollero; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

5.  Application of intra-oral dental scanners in the digital workflow of implantology.

Authors:  Wicher J van der Meer; Frank S Andriessen; Daniel Wismeijer; Yijin Ren
Journal:  PLoS One       Date:  2012-08-22       Impact factor: 3.240

6.  Accuracy of Proximal and Occlusal Contacts of Single Implant Crowns Fabricated Using Different Digital Scan Methods: An In Vitro Study.

Authors:  Xi Ren; Keunbada Son; Kyu-Bok Lee
Journal:  Materials (Basel)       Date:  2021-05-26       Impact factor: 3.623

7.  Dimensional accuracy of stone casts obtained with multiple pours into the same mold.

Authors:  Valdimar da Silva Valente; Artêmio Luiz Zanetti; Pedro Paulo Feltrin; Ricardo Tatsuo Inoue; Carmem Dolores Vilarinho Soares de Moura; Luiz Evaldo de Moura Pádua
Journal:  ISRN Dent       Date:  2012-12-24

8.  The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Maryam Kohsoltani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21

9.  Comparing the Accuracy of Three Different Impression Materials in Making Duplicate Dies.

Authors:  Farshad Bajoghli; Mahmoud Sabouhi; Saeid Nosouhian; Amin Davoudi; Zeynab Behnamnia
Journal:  J Int Oral Health       Date:  2015-07

10.  The evolution of dental materials for hybrid prosthesis.

Authors:  Jorge Gonzalez
Journal:  Open Dent J       Date:  2014-05-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.