Literature DB >> 24430014

Procedural guidance using advance imaging techniques for percutaneous edge-to-edge mitral valve repair.

Robert A Quaife1, Ernesto E Salcedo, John D Carroll.   

Abstract

The complexity of structural heart disease interventions such as edge-to edge mitral valve repair requires integration of multiple highly technical imaging modalities. Real time imaging with 3-dimensional (3D) echocardiography is a relatively new technique that first, allows clear volumetric imaging of target structures such as the mitral valve for both pre-procedural diagnosis and planning in patients with degenerative or functional mitral valve regurgitation. Secondly it provides intra-procedural, real-time panoramic volumetric 3D view of structural heart disease targets that facilitates eye-hand coordination while manipulating devices within the heart. X-ray fluoroscopy and RT 3D TEE images are used in combination to display specific targets and movement of catheter based technologies in 3D space. This integration requires at least two different image display monitors and mentally fusing the individual datasets by the operator. Combined display technology such as this, allow rotation and orientation of both dataset perspectives necessary to define targets and guidance of structural disease device procedures. The inherently easy concept of direct visual feedback and eye-hand coordination allows safe and efficient completion of MitraClip procedures. This technology is now merged into a single structural heart disease guidance mode called EchoNavigator(TM) (Philips Medical Imaging Andover, MA). These advanced imaging techniques have revolutionized the field of structural heart disease interventions and this experience is exemplified by a cooperative imaging approach used for guidance of edge-to-edge mitral valve repair procedures.

Entities:  

Mesh:

Year:  2014        PMID: 24430014     DOI: 10.1007/s11886-013-0452-5

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  16 in total

1.  Side-by-side comparison of fluoroscopy, 2D and 3D TEE during percutaneous edge-to-edge mitral valve repair.

Authors:  Francesco F Faletra; Giovanni Pedrazzini; Elena Pasotti; Tiziano Moccetti
Journal:  JACC Cardiovasc Imaging       Date:  2012-06

2.  Real-time 3D echocardiography-guided transcatheter device closure of atrial septal defects.

Authors:  Ross McKendrick; Carl Y Owada
Journal:  Catheter Cardiovasc Interv       Date:  2005-07       Impact factor: 2.692

3.  Intraprocedure guidance for percutaneous mitral valve interventions: TTE, TEE, ICE, or X-ray?

Authors:  Ted Feldman
Journal:  Catheter Cardiovasc Interv       Date:  2004-11       Impact factor: 2.692

4.  Abstracts of the Annual Symposium of Transcatheter Cardiovascular Therapeutics, October 22-27, 2006, Washington, DC, USA.

Authors: 
Journal:  Am J Cardiol       Date:  2006 Oct 22-27       Impact factor: 2.778

5.  Percutaneous mitral valve repair using the edge-to-edge technique: six-month results of the EVEREST Phase I Clinical Trial.

Authors:  Ted Feldman; Hal S Wasserman; Howard C Herrmann; William Gray; Peter C Block; Patrick Whitlow; Fred St Goar; Leonardo Rodriguez; Frank Silvestry; Allan Schwartz; Timothy A Sanborn; Jose A Condado; Elyse Foster
Journal:  J Am Coll Cardiol       Date:  2005-10-19       Impact factor: 24.094

Review 6.  Interventional three-dimensional echocardiography: using real-time three-dimensional echocardiography to guide and evaluate intracardiac therapies.

Authors:  Edward A Gill; David H Liang
Journal:  Cardiol Clin       Date:  2007-05       Impact factor: 2.213

7.  Transcatheter valve repair/implantation.

Authors:  Robert J Siegel; Huai Luo; Simon Biner
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-23       Impact factor: 2.357

8.  Utility of combined two-dimensional and three-dimensional transesophageal imaging for catheter-based mitral valve clip repair of mitral regurgitation.

Authors:  Simon Biner; Gila Perk; Saibal Kar; Asim M Rafique; James Slater; Takahiro Shiota; Asma Hussaini; Stanley Chou; Itzhak Kronzon; Robert J Siegel
Journal:  J Am Soc Echocardiogr       Date:  2011-03-23       Impact factor: 5.251

Review 9.  Three-dimensional echocardiography: historical development and current applications.

Authors:  A Lange; P Palka; D J Burstow; M J Godman
Journal:  J Am Soc Echocardiogr       Date:  2001-05       Impact factor: 5.251

10.  Real-time three-dimensional transesophageal echocardiography for guiding interventional electrophysiology: feasibility study.

Authors:  Eric C Pua; Salim F Idriss; Patrick D Wolf; S W Smith
Journal:  Ultrason Imaging       Date:  2007-07       Impact factor: 1.578

View more
  8 in total

Review 1.  Innovation in 3D Echocardiographic Imaging.

Authors:  Pei-Ni Jone; Nee Khoo
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-01-19

Review 2.  Hybrid Imaging During Transcatheter Structural Heart Interventions.

Authors:  Patric Biaggi; Covadonga Fernandez-Golfín; Rebecca Hahn; Roberto Corti
Journal:  Curr Cardiovasc Imaging Rep       Date:  2015

Review 3.  MitraClip step by step; how to simplify the procedure.

Authors:  M A Sherif; L Paranskaya; S Yuecel; S Kische; O Thiele; G D'Ancona; A Neuhausen-Abramkina; J Ortak; H Ince; A Öner
Journal:  Neth Heart J       Date:  2017-02       Impact factor: 2.380

Review 4.  Real-Time Monitoring and Step-by-Step Guidance for Transapical Mitral Valve Edge-to-Edge Repair Using Transesophageal Echocardiography.

Authors:  Zhenyi Ge; Cuizhen Pan; Wei Li; Daxin Zhou; Wenzhi Pan; Lai Wei; Haiyan Chen; Xianhong Shu; Junbo Ge
Journal:  J Interv Cardiol       Date:  2021-04-21       Impact factor: 2.279

5.  Demonstration of Use of a Novel 3D Printed Simulator for Mitral Valve Transcatheter Edge-to-Edge Repair (TEER).

Authors:  Michele Bertolini; Michael Mullen; Georgios Belitsis; Angel Babu; Giorgio Colombo; Andrew Cook; Aigerim Mullen; Claudio Capelli
Journal:  Materials (Basel)       Date:  2022-06-17       Impact factor: 3.748

Review 6.  Recent advances in echocardiography for valvular heart disease.

Authors:  Rebecca Hahn
Journal:  F1000Res       Date:  2015-09-28

Review 7.  Role of 3D Echocardiography in Cardiac Surgery: Strengths and Limitations.

Authors:  Edwin Wilberforce Turton; Jörg Ender
Journal:  Curr Anesthesiol Rep       Date:  2017-07-21

8.  Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy.

Authors:  S Afzal; V Veulemans; J Balzer; T Rassaf; K Hellhammer; A Polzin; M Kelm; T Zeus
Journal:  Neth Heart J       Date:  2017-02       Impact factor: 2.380

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.