Literature DB >> 11337688

Three-dimensional echocardiography: historical development and current applications.

A Lange1, P Palka, D J Burstow, M J Godman.   

Abstract

Three-dimensional (3D) echocardiography facilitates spatial recognition of intracardiac structures, potentially enhancing diagnostic confidence of conventional echocardiography. The accuracy of 3D images has been validated in vitro and in vivo. In vitro, a detail 1.0 mm in dimension and 2 details separated by 1.0 mm can be identified from a volume-rendered 3D image. In vitro 3D volume measurements are underestimated by approximately 4.0 mL. In vivo, left ventricular volume measurements correlate highly with both cineventriculography (limits of agreement +/-18 mL for end diastole and +/-10 mL for end systole) and magnetic resonance imaging, including measurements for patients with functionally single ventricles. Studies on congenital heart lesions have shown good accuracy and good reproducibility of dynamic "surgical" reconstructions of septal defects, aortoseptal continuity, atrioventricular junction, and both left and right ventricular outflow tract morphology. Transthoracic 3D echocardiography was shown feasible in 81% to 96% of patients with congenital heart defects and provided additional information to that available from conventional echocardiography in 36% of patients, mainly in more detailed description of mitral valve morphology, aortoseptal continuity, and atrial septum. In patients with mitral valve insufficiency, 3D echocardiography was shown to be accurate in the quantification of the dynamic mechanism of mitral regurgitation and in the assessment of mitral commissures in patients with mitral stenosis. This includes not only valve tissue reconstruction but also color flow intracardiac jets. Three-dimensional reconstructions of the aortic valve were achieved in 77% of patients, with an accuracy of 90%. In conclusion, the role of 3D echocardiography, which continues to evolve, shows promise in the assessment of congenital and acquired heart disease.

Entities:  

Mesh:

Year:  2001        PMID: 11337688     DOI: 10.1067/mje.2001.113147

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  9 in total

1.  [Three-dimensional echocardiography in cardiac surgery. Current status and perspectives].

Authors:  M R Hoda; T Schwarz; I Wolf; S Mottl-Link; H P Meinzer; M Karck; R De Simone
Journal:  Chirurg       Date:  2007-05       Impact factor: 0.955

2.  The basics of echocardiography.

Authors:  Alaa A Mohamed; Ahmed A Arifi; Ahmed Omran
Journal:  J Saudi Heart Assoc       Date:  2010-03-01

Review 3.  3D and 4D echo--applications in EP laboratory procedures.

Authors:  Josef Kautzner; Petr Peichl
Journal:  J Interv Card Electrophysiol       Date:  2008-04-18       Impact factor: 1.900

Review 4.  Procedural guidance using advance imaging techniques for percutaneous edge-to-edge mitral valve repair.

Authors:  Robert A Quaife; Ernesto E Salcedo; John D Carroll
Journal:  Curr Cardiol Rep       Date:  2014-02       Impact factor: 2.931

5.  Usefulness of the multiplanar reformatting mode of three-dimensional echocardiography in evaluating valvular and structural heart disease: An experience from Saudi Arabia.

Authors:  Saad Q Khoshhal
Journal:  J Saudi Heart Assoc       Date:  2013-11-13

6.  Left atrial and left ventricular function in healthy children and young adults assessed by three dimensional echocardiography.

Authors:  T Poutanen; E Jokinen; H Sairanen; T Tikanoja
Journal:  Heart       Date:  2003-05       Impact factor: 5.994

7.  Head to head comparison of 2D vs real time 3D dipyridamole stress echocardiography.

Authors:  Silvia Varnero; Patricia Santagata; Lorenza Pratali; Massimiliano Basso; Alfredo Gandolfo; Paolo Bellotti
Journal:  Cardiovasc Ultrasound       Date:  2008-06-20       Impact factor: 2.062

8.  Reproducibility of a novel echocardiographic 3D automated software for the assessment of mitral valve anatomy.

Authors:  Iolanda Aquila; Ariana González; Covadonga Fernández-Golfín; Luis Miguel Rincón; Eduardo Casas; Ana García; Rocio Hinojar; José Julio Jiménez-Nacher; José Luis Zamorano
Journal:  Cardiovasc Ultrasound       Date:  2016-05-17       Impact factor: 2.062

9.  Additive value of 3D-echo in prediction of immediate outcome after percutaneous balloon mitral valvuloplasty.

Authors:  Hazem M A Farrag; Amr M Setouhi; Mustafa O El-Mokadem; Mustafa A El-Swasany; Khalid S Mahmoud; Hesham B Mahmoud; Alaa M Ibrahim
Journal:  Egypt Heart J       Date:  2019-09-18
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.