Literature DB >> 21344247

Transcatheter valve repair/implantation.

Robert J Siegel1, Huai Luo, Simon Biner.   

Abstract

Real time 3-dimensional transesophageal echo is a relatively new technology that enables online imaging that is highly accurate and precise for evaluating cardiac structures. Moreover, this methodology allows for accurate online guidance of interventional cardiac procedures for structural heart disease. In this report, we describe the use of real time, 3D transesophageal (TEE) for aortic valve replacement with percutaneous, bioprosthetic valves as well as for transcatheter mitral repair with the MitraClip device. For each procedure, we describe 3D evaluation of valvular structures prior to the procedure, and how 3D imaging is used to guide the procedure as well as to assess the results of the procedure. Use of 3D TEE has proven to be a substantial advance for evaluating patients prior to percutaneous heart valve procedures and especially for guiding and monitoring percutaneous, transcatheter heart valve procedures.

Entities:  

Mesh:

Year:  2011        PMID: 21344247     DOI: 10.1007/s10554-011-9833-2

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  18 in total

1.  Real time volumetric ultrasound imaging system.

Authors:  O T von Ramm; S W Smith
Journal:  J Digit Imaging       Date:  1990-11       Impact factor: 4.056

2.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.

Authors:  Martin B Leon; Craig R Smith; Michael Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; David L Brown; Peter C Block; Robert A Guyton; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Pamela S Douglas; John L Petersen; Jodi J Akin; William N Anderson; Duolao Wang; Stuart Pocock
Journal:  N Engl J Med       Date:  2010-09-22       Impact factor: 91.245

3.  Real-time 3D TEE allows optimized guidance of percutaneous edge-to-edge repair of the mitral valve.

Authors:  Ertunc Altiok; Michael Becker; Sandra Hamada; Eva Grabskaya; Sebastian Reith; Nikolaus Marx; Rainer Hoffmann
Journal:  JACC Cardiovasc Imaging       Date:  2010-11

Review 4.  Three-dimensional imaging in the context of minimally invasive and transcatheter cardiovascular interventions using multi-detector computed tomography: from pre-operative planning to intra-operative guidance.

Authors:  Paul Schoenhagen; Uma Numburi; Sandra S Halliburton; Peter Aulbach; Martin von Roden; Milind Y Desai; Leonardo L Rodriguez; Samir R Kapadia; E Murat Tuzcu; Bruce W Lytle
Journal:  Eur Heart J       Date:  2010-08-25       Impact factor: 29.983

5.  Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions.

Authors:  Gila Perk; Roberto M Lang; Miguel Angel Garcia-Fernandez; Joe Lodato; Lissa Sugeng; John Lopez; Brad P Knight; David Messika-Zeitoun; Sanjiv Shah; James Slater; Eric Brochet; Mathew Varkey; Ziyad Hijazi; Nino Marino; Carlos Ruiz; Itzhak Kronzon
Journal:  J Am Soc Echocardiogr       Date:  2009-08       Impact factor: 5.251

6.  Utility of combined two-dimensional and three-dimensional transesophageal imaging for catheter-based mitral valve clip repair of mitral regurgitation.

Authors:  Simon Biner; Gila Perk; Saibal Kar; Asim M Rafique; James Slater; Takahiro Shiota; Asma Hussaini; Stanley Chou; Itzhak Kronzon; Robert J Siegel
Journal:  J Am Soc Echocardiogr       Date:  2011-03-23       Impact factor: 5.251

7.  Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis.

Authors:  Corrado Tamburino; Davide Capodanno; Angelo Ramondo; Anna Sonia Petronio; Federica Ettori; Gennaro Santoro; Silvio Klugmann; Francesco Bedogni; Francesco Maisano; Antonio Marzocchi; Arnaldo Poli; David Antoniucci; Massimo Napodano; Marco De Carlo; Claudia Fiorina; Gian Paolo Ussia
Journal:  Circulation       Date:  2011-01-10       Impact factor: 29.690

8.  Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description.

Authors:  Alain Cribier; Helene Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Genevieve Derumeaux; Frederic Anselme; François Laborde; Martin B Leon
Journal:  Circulation       Date:  2002-12-10       Impact factor: 29.690

9.  Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence.

Authors:  Delphine Détaint; Laurent Lepage; Dominique Himbert; Eric Brochet; David Messika-Zeitoun; Bernard Iung; Alec Vahanian
Journal:  JACC Cardiovasc Interv       Date:  2009-09       Impact factor: 11.195

Review 10.  Catheter-based approach to mitral regurgitation.

Authors:  Jóse Antonio Condado; Manuel Vélez-Gimón
Journal:  J Interv Cardiol       Date:  2003-12       Impact factor: 2.279

View more
  7 in total

Review 1.  Procedural guidance using advance imaging techniques for percutaneous edge-to-edge mitral valve repair.

Authors:  Robert A Quaife; Ernesto E Salcedo; John D Carroll
Journal:  Curr Cardiol Rep       Date:  2014-02       Impact factor: 2.931

Review 2.  Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI).

Authors:  Paul Schoenhagen; Jörg Hausleiter; Stephan Achenbach; Milind Y Desai; E Murat Tuzcu
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

Review 3.  Transcatheter aortic valve repair, imaging, and electronic imaging health record.

Authors:  Paul Schoenhagen; Juergen Falkner; David Piraino
Journal:  Curr Cardiol Rep       Date:  2013-01       Impact factor: 2.931

4.  Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging.

Authors:  Gokce Gurun; Coskun Tekes; Jaime Zahorian; Toby Xu; Sarp Satir; Mustafa Karaman; Jennifer Hasler; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-02       Impact factor: 2.725

5.  Short-term and 1-year outcomes after MitraClip therapy in functional versus degenerative mitral regurgitation patients: a systematic review and meta-analysis.

Authors:  Xiao-Hang Liu; Jia-Yu Shi; Xiao-Jin Feng; Dong-Cai Feng; Lin Wang; Hai-Yu Pang; Hong-Zhi Xie; Fang-Fei Wang; Jeffrey Hsu; Fu-Wei Jia; Wei Chen
Journal:  J Thorac Dis       Date:  2018-07       Impact factor: 2.895

Review 6.  Cardiovascular imaging 2011 in the International Journal of Cardiovascular Imaging.

Authors:  Ricardo A Costa; Hiram G Bezerra; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2012-03       Impact factor: 2.357

Review 7.  Echocardiography in transcatheter aortic valve implantation and mitral valve clip.

Authors:  Robert J Siegel; Huai Luo
Journal:  Korean J Intern Med       Date:  2012-09-01       Impact factor: 2.884

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.