| Literature DB >> 24406663 |
Evy Lahou1, Mieke Uyttendaele2.
Abstract
Listeria monocytogenes can adhere to different types of food contact surfaces within a food processing environment. Therefore, environmental sampling devices should be capable of detecting unacceptable contamination. In this study, a sponge-stick, foam spatula and an environmental swab were evaluated on their ability to detect low concentrations of L. monocytogenes on different types of food contact surfaces. A cocktail of four L. monocytogenes serotypes was inoculated with a concentration of 100 CFU/250 cm2 onto stainless steel (SS), high density polyethylene (HDPE) and rubber surfaces in a 250 cm2 area. Immediately after inoculation and after 1 h exposure, the surfaces were swabbed with the different swabbing devices. The results of the study show only minor differences in the ability of the swabbing devices to detect L. monocytogenes. All devices were capable to detect the contamination immediately after inoculation. However, when the surfaces were allowed to air-dry for 1 h, L. monocytogenes was undetected in 11.1% of the samples (n = 27) with the sponge stick, in 7.4% of the samples (n = 27) with the foam spatula and in 3.7% of the samples (n = 27) with the environmental swab, especially on SS surfaces. The detection ability of the different devices for L. monocytogenes can be concluded to be rather high on different types of food contact surfaces.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24406663 PMCID: PMC3924475 DOI: 10.3390/ijerph110100804
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Figure 1This figure shows the technique of swabbing with an overlapping “S” pattern. The tip of the swab/sponge can be used to wipe the perimeter of the sampling area, resulting in an optimal use of the swab/sponge surface.
Results of the different swabbing devices when used for swabbing on stainless steel (SS), high density poly-ethylene (HDPE) and rubber. T0 is the sampling time immediately after inoculation, whilst the surface was still wet. T1 is the sampling time when the surface had been allowed to air-dry for 1 h at room temperature. “+” is used when the swabbing device could detect L. monocytogenes. “−” is used when the swabbing device could not detect L. monocytogenes.
| 3MTM Sponge-Stick | Copan Foam Spatula | 3MTM Enviro Swab | ||||
|---|---|---|---|---|---|---|
| T0 | T1 | T0 | T1 | T0 | T1 | |
| SS | + | + | + | + | + | + |
| + | + | + | + | + | + | |
| + | + | + | − | + | + | |
| + | + | + | + | + | + | |
| + | − | + | + | + | + | |
| + | − | + | + | + | + | |
| + | + | + | + | + | + | |
| + | − | + | + | + | − | |
| + | + | + | + | + | + | |
| HDPE | + | + | + | − | + | + |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| Rubber | + | + | + | + | + | + |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |
| + | + | + | + | + | + | |