Literature DB >> 24402473

Primary total hip arthroplasty with a proximally HA-coated titanium femoral component: results at 10-15-year follow-up.

N A Sandiford1, A Butler-Manuel, H D Apthorp, D J East, B L Hinves, J A N Shepperd.   

Abstract

INTRODUCTION: Registries in both the United Kingdom and Sweden suggest that the popularity of uncemented femoral components is increasing. As this trend progresses, long-term survival data for such components are becoming increasingly more important. We present the results of a cohort of patients treated with the Omnifit (Stryker, Mahwah, NJ) femoral component with the follow-up of 10-15 years.
METHODS: A prospective study was performed in our unit between 1996 and 2001. Patients were reviewed pre-operatively and then at 6, 12, 26 and 52 weeks post-operatively and annually thereafter. They were assessed clinically and radiographically, and the Merle d'Aubigne Postel (MDP) hip score was calculated at each visit. A visual analogue scale (VAS) score and satisfaction score were also recorded to assess patient satisfaction with their procedure. Specific enquiry was made regarding anterior thigh pain. Statistical calculations were performed using the Student's t test. Kaplan-Meier survival analysis was performed.
RESULTS: One hundred and four patients (113 hips) were included (48 males, 56 females). Bilateral procedures were performed in nine patients. Mean age was 60.4 years (33-72 years). Mean follow-up was 12.9 years (10-15 years). Mean pre-operative MDP score was 8.8 (3-16) and VAS score 7.8 (1-10) with ten representing the most severe symptoms. At final follow-up, the average MDP and VAS scores were 16.9 (13-18) and 2.1 (0-6), respectively. High levels of satisfaction were reported by 96.1% of patients. Two dislocations and two cases of anterior thigh pain occurred. Four patients required revision surgery. Survival of the femoral component with revision for any reason as the end point was 96%.
CONCLUSION: This prosthesis provides symptom relief, return to function and high levels of patient satisfaction in the long term. Survival of this component is comparable to the best results for primary total hip arthroplasty with any means of fixation.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24402473     DOI: 10.1007/s00590-013-1405-9

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  12 in total

1.  Cementless total hip arthroplasty using the omnifit system: An 8.2 year follow-up study of 166 hips.

Authors:  Pang-Hsin Hsieh; Chun-Hsiung Shih; Po-Cheng Lee; Wen-E Yang; Zhou-Liau Lee
Journal:  J Orthop Surg (Hong Kong)       Date:  2000-12       Impact factor: 1.118

2.  The use of hydroxyapatite-coated CAD-CAM femoral components in adolescents and young adults with inflammatory polyarthropathy: ten-year results.

Authors:  C J McCullough; D Remedios; G Tytherleigh-Strong; J Hua; P S Walker
Journal:  J Bone Joint Surg Br       Date:  2006-07

3.  Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.

Authors:  P J Yates; B J Burston; E Whitley; G C Bannister
Journal:  J Bone Joint Surg Br       Date:  2008-01

4.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

5.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

6.  Omnifit cementless total hip arthroplasty. A 10-year average followup.

Authors:  E J Hellman; W N Capello; J R Feinberg
Journal:  Clin Orthop Relat Res       Date:  1999-07       Impact factor: 4.176

7.  The Exeter Universal stem: a minimum ten-year review from an independent centre.

Authors:  S Hook; E Moulder; P J Yates; B J Burston; E Whitley; G C Bannister
Journal:  J Bone Joint Surg Br       Date:  2006-12

8.  Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses.

Authors:  Alphons J Tonino; Bart C H van der Wal; Ide C Heyligers; Bernd Grimm
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

9.  Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old. A concise follow-up of a previous report.

Authors:  William N Capello; James A D'Antonio; Judy R Feinberg; Michael T Manley
Journal:  J Bone Joint Surg Am       Date:  2003-05       Impact factor: 5.284

Review 10.  Uncemented stems in hip replacement--hydroxyapatite or plain porous: does it matter? Based on a prospective study of HA Omnifit stems at 15-years minimum follow-up.

Authors:  J-A Epinette; M T Manley
Journal:  Hip Int       Date:  2008 Apr-Jun       Impact factor: 1.756

View more
  1 in total

1.  No decline in high patient satisfaction after total hip arthroplasty at long-term follow-up.

Authors:  P P Schmitz; J L C van Susante; A Hol; R Brokelman; C J M van Loon
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-06-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.