Omnifit cementless total hip arthroplasty. A 10-year average followup.

E J Hellman1, W N Capello, J R Feinberg.   

Abstract

Seventy-six hips in 67 patients were evaluated an average of 119 months (range, 61-150 months) after total hip arthroplasty with porous coated Omnifit femoral and acetabular components. The patients were young (average age, 45 years), and most were male (67%). Two stems and one cup were revised for aseptic loosening, for aseptic revision rates of 2.6% on the femoral side and 1.3% on the acetabular side. Thigh pain was present in three cases, one of which was activity limiting. Twenty-five (35.7%) hips had evidence of osteolysis confined to proximal Gruen Zone 1 or 7 or to the acetabulum (22 proximal femoral, three both). There were no cases of intramedullary osteolysis in surviving stems. Thirteen (17.1%) hips have undergone reoperation for bone grafting of progressive proximal osteolysis without component revision, at an average 93 months after the total hip arthroplasty. At an average 40 months after reoperation, all stems remain well fixed, and there has been no recurrence of osteolysis of grafted femoral lesions. These results suggest that a circumferentially proximally porous coated femoral component in cementless total hip arthroplasty can provide stable fixation for as long as 12 years after implantation and caseal the canal from distal osteolysis. Serious concerns remain about the incidence of proximal femoral osteolysis.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10416406     DOI: 10.1097/00003086-199907000-00022

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  11 in total

1.  Does smoking affect implant survivorship in total hip arthroplasty? A preliminary retrospective case series.

Authors:  Russell D Meldrum; L Daniel Wurtz; Judy R Feinberg; William N Capello
Journal:  Iowa Orthop J       Date:  2005

2.  Primary total hip arthroplasty with a proximally HA-coated titanium femoral component: results at 10-15-year follow-up.

Authors:  N A Sandiford; A Butler-Manuel; H D Apthorp; D J East; B L Hinves; J A N Shepperd
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-01-09

3.  Ceramic bearings for total hip arthroplasty have high survivorship at 10 years.

Authors:  James A D'Antonio; William N Capello; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  Bone Remodeling of Two Anatomic Stems: Densitometric Study of the Redesign of the ABG-II Stem.

Authors:  Juan J Panisello; Jorge Lopez; Marina Lillo; Jesus Mateo; Carlos Martin; Antonio Herrera
Journal:  Arthroplast Today       Date:  2020-07-03

Review 5.  Femoral osteolysis following total hip replacement.

Authors:  R Dattani
Journal:  Postgrad Med J       Date:  2007-05       Impact factor: 2.401

6.  The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

Authors:  Donald S Garbuz; Michael Tanzer; Nelson V Greidanus; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2009-08-21       Impact factor: 4.176

7.  Avascular necrosis of the hip in a 41-year-old male: a case study.

Authors:  Rahim Karim; Kambiz D Goel
Journal:  J Can Chiropr Assoc       Date:  2004-06

8.  No improvement in long-term wear and revision rates with the second-generation Biomet cup (RingLoc) in young patients: 141 hips followed for median 12 years.

Authors:  Bart Boesenach; Huub J L van der Heide; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2011-11-09       Impact factor: 3.717

9.  5-year clinical and radiographic follow-up of the uncemented Symax hip stem in an international study.

Authors:  Dennis Silvester Maria Gerardus Kruijntjens; Per Kjaersgaard-Andersen; Peter Revald; Jane Schwartz Leonhardt; Jacobus Johannes Chris Arts; René Hendrikus Maria Ten Broeke
Journal:  J Orthop Surg Res       Date:  2018-07-31       Impact factor: 2.359

Review 10.  Material Science in Cervical Total Disc Replacement.

Authors:  Martin H Pham; Vivek A Mehta; Alexander Tuchman; Patrick C Hsieh
Journal:  Biomed Res Int       Date:  2015-10-07       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.