Literature DB >> 18160493

Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.

P J Yates1, B J Burston, E Whitley, G C Bannister.   

Abstract

We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip score. Radiological analysis was performed on calibrated plain radiographs taken in two planes. Complete radiological data on 110 patients (120 hips) and clinical follow-up on all the surviving 111 patients (122 hips) was available. The fate of all the hips was known. At final follow-up, the mean Harris Hip score was 86 (47 to 100), and 87 of 116 patients (75%) had good or excellent scores. Survival with revision of the stem for aseptic loosening as the endpoint was 100%; and survival with revision of the stem for any reason was 95.9% (95% confidence interval 87.8 to 96.8) at ten years. All the stems subsided vertically at the stem-cement interface in a predictable pattern, at an overall mean rate of 0.18 mm per year (0.02 to 2.16), but with a mean rate of 0.80 mm (0.02 to 2.5) during the first year. The mean total subsidence was 1.95 mm (0.21 to 24). Only three stems loosened at the cement-bone interface. There was excellent preservation of proximal femoral bone stock. There was a high incidence of Brooker III and IV heterotopic ossification affecting 25 patients (22%). The collarless polished tapered stem has an excellent clinical and radiological outcome at a minimum of ten years' follow-up. The pattern and magnitude of subsidence of the stem within the cement mantle occurred in a predictable pattern, consistent with the design philosophy.

Entities:  

Mesh:

Year:  2008        PMID: 18160493     DOI: 10.1302/0301-620X.90B1.19546

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

1.  Primary total hip arthroplasty with a proximally HA-coated titanium femoral component: results at 10-15-year follow-up.

Authors:  N A Sandiford; A Butler-Manuel; H D Apthorp; D J East; B L Hinves; J A N Shepperd
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-01-09

2.  The effect of a collar and surface finish on cemented femoral stems: a prospective randomised trial of four stem designs.

Authors:  Jonathan Hutt; Alexandra Hazlerigg; Ansari Aneel; Geoffrey Epie; Husam Dabis; Roy Twyman; Andrew Cobb
Journal:  Int Orthop       Date:  2014-01-29       Impact factor: 3.075

3.  Total hip replacement with a collarless polished cemented anatomic stem: clinical and gait analysis results at ten years follow-up.

Authors:  Arthur Grzesiak; Kamiar Aminian; Estelle Lécureux; Florence Jobin; Brigitte M Jolles
Journal:  Int Orthop       Date:  2013-12-19       Impact factor: 3.075

4.  Reduced femoral component subsidence with improved impaction grafting at revision hip arthroplasty.

Authors:  D W Howie; S A Callary; M A McGee; N C Russell; L B Solomon
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

5.  Femoral bone is preserved using cemented polished stems in young patients.

Authors:  Donald W Howie; Kerry Costi; Margaret A McGee; Angela Standen; Lucian B Solomon
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

6.  Deep Learning for Radiographic Measurement of Femoral Component Subsidence Following Total Hip Arthroplasty.

Authors:  Pouria Rouzrokh; Cody C Wyles; Shyam J Kurian; Taghi Ramazanian; Jason C Cai; Qiao Huang; Kuan Zhang; Michael J Taunton; Hilal Maradit Kremers; Bradley J Erickson
Journal:  Radiol Artif Intell       Date:  2022-05-04

Review 7.  Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review.

Authors:  Kwaku Baryeh; Jeewaka Mendis; David H Sochart
Journal:  EFORT Open Rev       Date:  2021-05-04

8.  Minimum ten-year outcome of a triple-tapered femoral stem implanted with line-to-line cementing technique.

Authors:  Hirotsugu Ohashi; Satoshi Iida; Izumi Minato
Journal:  BMC Musculoskelet Disord       Date:  2021-06-30       Impact factor: 2.362

9.  High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem.

Authors:  Cyrus Brodén; Sebastian Mukka; Olle Muren; Thomas Eisler; Henrik Boden; André Stark; Olof Sköldenberg
Journal:  Acta Orthop       Date:  2014-10-03       Impact factor: 3.717

10.  Substantially higher prevalence of postoperative peri-prosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem.

Authors:  Sebastian Mukka; Carl Mellner; Björn Knutsson; Arkan Sayed-Noor; Olof Sköldenberg
Journal:  Acta Orthop       Date:  2016-04-04       Impact factor: 3.717

View more