Literature DB >> 24401558

The appropriate and justified use of medical radiation in cardiovascular imaging: a position document of the ESC Associations of Cardiovascular Imaging, Percutaneous Cardiovascular Interventions and Electrophysiology.

Eugenio Picano1, Eliseo Vañó, Madan M Rehani, Alberto Cuocolo, Lluis Mont, Vicente Bodi, Olivier Bar, Carlo Maccia, Luc Pierard, Rosa Sicari, Sven Plein, Heiko Mahrholdt, Patrizio Lancellotti, Juhani Knuuti, Hein Heidbuchel, Carlo Di Mario, Luigi P Badano.   

Abstract

The benefits of cardiac imaging are immense, and modern medicine requires the extensive and versatile use of a variety of cardiac imaging techniques. Cardiologists are responsible for a large part of the radiation exposures every person gets per year from all medical sources. Therefore, they have a particular responsibility to avoid unjustified and non-optimized use of radiation, but sometimes are imperfectly aware of the radiological dose of the examination they prescribe or practice. This position paper aims to summarize the current knowledge on radiation effective doses (and risks) related to cardiac imaging procedures. We have reviewed the literature on radiation doses, which can range from the equivalent of 1-60 milliSievert (mSv) around a reference dose average of 15 mSv (corresponding to 750 chest X-rays) for a percutaneous coronary intervention, a cardiac radiofrequency ablation, a multidetector coronary angiography, or a myocardial perfusion imaging scintigraphy. We provide a European perspective on the best way to play an active role in implementing into clinical practice the key principle of radiation protection that: 'each patient should get the right imaging exam, at the right time, with the right radiation dose'.

Entities:  

Keywords:  Cancer; Cardiovascular disease; Imaging; Radiation; Radiological protection; Risk

Mesh:

Year:  2014        PMID: 24401558     DOI: 10.1093/eurheartj/eht394

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  61 in total

Review 1.  Screening for cardiovascular disease before kidney transplantation.

Authors:  Sneha Palepu; G V Ramesh Prasad
Journal:  World J Transplant       Date:  2015-12-24

2.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  J Interv Card Electrophysiol       Date:  2020-10       Impact factor: 1.900

3.  Fluoroscopy-free recrossing of the interatrial septum during left atrial ablation procedures.

Authors:  Nikola Pavlović; Tobias Reichlin; Michael Kühne; Sven Knecht; Stefan Osswald; Christian Sticherling
Journal:  J Interv Card Electrophysiol       Date:  2014-11-15       Impact factor: 1.900

4.  Beyond ultrasound: advances in multimodality cardiac imaging.

Authors:  Carmela Nappi; Wanda Acampa; Teresa Pellegrino; Mario Petretta; Alberto Cuocolo
Journal:  Intern Emerg Med       Date:  2014-07-19       Impact factor: 3.397

5.  ["Zero fluoro"-a chance for more women in electrophysiology].

Authors:  Johanna Müller-Leisse; Henrike Aenne Katrin Hillmann; Christian Veltmann; David Duncker
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2021-05-04

6.  The lateral plane delivers higher dose than the frontal plane in biplane cardiac catheterization systems.

Authors:  Osamah Aldoss; Sonali Patel; Kyle Harris; Abhay Divekar
Journal:  Pediatr Cardiol       Date:  2015-01-14       Impact factor: 1.655

7.  Radiation protection training for cardiologists in the era of multiple imaging techniques and complex interventions.

Authors:  Elved B Roberts; Debbie J Peet
Journal:  Br J Radiol       Date:  2016-09-15       Impact factor: 3.039

8.  Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol.

Authors:  Laetitia Imbert; Véronique Roch; Charles Merlin; Wassila Djaballah; Florent Cachin; Mathieu Perrin; Marine Claudin; Antoine Verger; Henri Boutley; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2017-05-16       Impact factor: 5.952

Review 9.  Multimodality imaging assessment of bicuspid aortic valve disease, thoracic aortic ectasia, and thoracic aortic aneurysmal disease.

Authors:  Preethi Mani; Reza Reyaldeen; Bo Xu
Journal:  Cardiovasc Diagn Ther       Date:  2021-06

10.  Reduction of radiation exposure in catheter ablation of atrial fibrillation: Lesson learned.

Authors:  Roberto De Ponti
Journal:  World J Cardiol       Date:  2015-08-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.