Literature DB >> 26322183

Reduction of radiation exposure in catheter ablation of atrial fibrillation: Lesson learned.

Roberto De Ponti1.   

Abstract

Over the last decades, the concern for the radiation injury hazard to the patients and the professional staff has increased in the medical community. Since there is no magnitude of radiation exposure that is known to be completely safe, the use of ionizing radiation during medical diagnostic or interventional procedures should be as low as reasonably achievable (ALARA principle). Nevertheless, in cardiovascular medicine, radiation exposure for coronary percutaneous interventions or catheter ablation of cardiac arrhythmias may be high: for ablation of a complex arrhythmia, such as atrial fibrillation, the mean dose can be > 15 mSv and in some cases > 50 mSv. In interventional electrophysiology, although fluoroscopy has been widely used since the beginning to navigate catheters in the heart and the vessels and to monitor their position, the procedure is not based on fluoroscopic imaging. Therefore, non-fluoroscopic three-dimensional systems can be used to navigate electrophysiology catheters in the heart with no or minimal use of fluoroscopy. Although zero-fluoroscopy procedures are feasible in limited series, there may be difficulties in using no fluoroscopy on a routine basis. Currently, a significant reduction in radiation exposure towards near zero-fluoroscopy procedures seems a simpler task to achieve, especially in ablation of complex arrhythmias, such as atrial fibrillation. The data reported in the literature suggest the following three considerations. First, the use of the non-fluoroscopic systems is associated with a consistent reduction in radiation exposure in multiple centers: the more sophisticated and reliable this technology is, the higher the reduction in radiation exposure. Second, the use of these systems does not automatically lead to reduction of radiation exposure, but an optimized workflow should be developed and adopted for a safe non-fluoroscopic navigation of catheters. Third, at any level of expertise, there is a specific learning curve for the operators in the non-fluoroscopic manipulation of catheters; however, the learning curve is shorter for more experienced operators compared to less experienced operators.

Entities:  

Keywords:  Atrial fibrillation; Catheter ablation; Dose area product; Electroanatomic mapping; Fluoroscopy time; Radiation exposure

Year:  2015        PMID: 26322183      PMCID: PMC4549777          DOI: 10.4330/wjc.v7.i8.442

Source DB:  PubMed          Journal:  World J Cardiol


  30 in total

1.  Simulator training reduces radiation exposure and improves trainees' performance in placing electrophysiologic catheters during patient-based procedures.

Authors:  Roberto De Ponti; Raffaella Marazzi; Lorenzo A Doni; Claudio Tamborini; Sergio Ghiringhelli; Jorge A Salerno-Uriarte
Journal:  Heart Rhythm       Date:  2012-04-16       Impact factor: 6.343

2.  Elimination of fluoroscopy use in a pediatric electrophysiology laboratory utilizing three-dimensional mapping.

Authors:  Grace Smith; John M Clark
Journal:  Pacing Clin Electrophysiol       Date:  2007-04       Impact factor: 1.976

3.  Significant reduction of fluoroscopy in pediatric catheter ablation procedures: long-term experience from a single center.

Authors:  Volkan Tuzcu
Journal:  Pacing Clin Electrophysiol       Date:  2012-07-21       Impact factor: 1.976

Review 4.  "Near-zero" fluoroscopic exposure in supraventricular arrhythmia ablation using the EnSite NavX™ mapping system: personal experience and review of the literature.

Authors:  Michela Casella; Gemma Pelargonio; Antonio Dello Russo; Stefania Riva; Stefano Bartoletti; Pasquale Santangeli; Antonio Scarà; Tommaso Sanna; Riccardo Proietti; Luigi Di Biase; G Joseph Gallinghouse; Maria Lucia Narducci; Luigi Sisto; Fulvio Bellocci; Andrea Natale; Claudio Tondo
Journal:  J Interv Card Electrophysiol       Date:  2011-03-02       Impact factor: 1.900

5.  Cumulative exposure to ionizing radiation from diagnostic and therapeutic cardiac imaging procedures: a population-based analysis.

Authors:  Jersey Chen; Andrew J Einstein; Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Henry H Ting; Nilay D Shah; Khurram Nasir; Brahmajee K Nallamothu
Journal:  J Am Coll Cardiol       Date:  2010-07-09       Impact factor: 24.094

6.  Contact force-controlled zero-fluoroscopy catheter ablation of right-sided and left atrial arrhythmia substrates.

Authors:  Gunter Kerst; Hans-Jörg Weig; Slawomir Weretka; Peter Seizer; Michael Hofbeck; Meinrad Gawaz; Jürgen Schreieck
Journal:  Heart Rhythm       Date:  2012-01-02       Impact factor: 6.343

7.  Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping.

Authors:  John D Ferguson; Adam Helms; J Michael Mangrum; Srijoy Mahapatra; Pamela Mason; Ken Bilchick; George McDaniel; David Wiggins; John P DiMarco
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12

8.  Safety and feasibility of catheter ablation for atrioventricular nodal re-entrant tachycardia without fluoroscopic guidance.

Authors:  Miguel Alvarez; Luís Tercedor; Isabel Almansa; Natalia Ros; Ricardo S Galdeano; Francisco Burillo; Pablo Santiago; Rocío Peñas
Journal:  Heart Rhythm       Date:  2009-09-03       Impact factor: 6.343

9.  Reassessment of radiation risks from electrophysiology procedures compared to coronary angiography.

Authors:  Ian R Smith; John T Rivers; John Hayes; Wayne Stafford; Catrina Codd
Journal:  Heart Lung Circ       Date:  2008-12-31       Impact factor: 2.975

10.  Exclusion of fluoroscopy during ablation treatment of right accessory pathway in children.

Authors:  Fabrizio Drago; Massimo Stefano Silvetti; Alfredo Di Pino; Giorgia Grutter; Maurizio Bevilacqua; Shoshana Leibovich
Journal:  J Cardiovasc Electrophysiol       Date:  2002-08
View more
  7 in total

1.  Magnetic resonance imaging guided transatrial electrophysiological studies in swine using active catheter tracking - experience with 14 cases.

Authors:  Matthias Grothoff; Matthias Gutberlet; Gerhard Hindricks; Christian Fleiter; Bernhard Schnackenburg; Steffen Weiss; Sascha Krueger; Christopher Piorkowski; Thomas Gaspar; Steve Wedan; Thomas Lloyd; Philipp Sommer; Sebastian Hilbert
Journal:  Eur Radiol       Date:  2016-08-23       Impact factor: 5.315

2.  Implementation of a near-zero fluoroscopy approach in interventional electrophysiology: impact of operator experience.

Authors:  Severin Wannagat; Lena Loehr; Sebastian Lask; Katharina Völk; Tamer Karaköse; Cemil Özcelik; Andreas Mügge; Alexander Wutzler
Journal:  J Interv Card Electrophysiol       Date:  2018-02-19       Impact factor: 1.900

3.  Reduced motion external defibrillation: Reduced subject motion with equivalent defibrillation efficiency validated in swine.

Authors:  Ehud J Schmidt; Hassan Elahi; Eric S Meyer; Ryan Baumgaertner; Luca Neri; Ronald D Berger; Harikrishna Tandri; David W Hunter; Steven P Cohen; Matt T Oberdier; Henry R Halperin
Journal:  Heart Rhythm       Date:  2022-02-28       Impact factor: 6.779

4.  Remote magnetic catheter navigation versus conventional ablation in atrial fibrillation ablation: Fluoroscopy reduction.

Authors:  Paul Chun Yih Lim; Joseph Jia Hong Toh; Julian Kenrick Xing Yuan Loh; Edward Chun Yi Lee; Daniel Thuan Tee Chong; Boon Yew Tan; Kah Leng Ho; Chi Keong Ching; Wee Siong Teo
Journal:  J Arrhythm       Date:  2016-11-10

5.  Extensive Use of 3D Nonfluoroscopic Mapping Systems for Reducing Radiation Exposure during Catheter Ablation Procedures: An Analysis of 10 Years of Activity.

Authors:  Massimiliano Marini; Marta Martin; Daniele Ravanelli; Maurizio Del Greco; Silvia Quintarelli; Fabrizio Guarracini; Alessio Coser; Aldo Valentini; Roberto Bonmassari
Journal:  Biomed Res Int       Date:  2019-03-10       Impact factor: 3.411

6.  Assessment of DNA Damage After Ionizing Radiation Exposure in Patients Undergoing Cardiac Resynchronization Therapy Device Implantation or Atrial Fibrillation Ablation (The RADAR Study).

Authors:  Mohit K Turagam; Venkat Vuddanda; Donita Atkins; Rakesh Venkata; Bhavya Yarlagadda; Himabindu Korra; Jaya Pitchika; Sudharani Bommana; Dhanujaya R Lakkireddy
Journal:  J Atr Fibrillation       Date:  2018-08-31

7.  A decade of catheter ablation of cardiac arrhythmias in Sweden: ablation practices and outcomes.

Authors:  Fredrik Holmqvist; Milos Kesek; Anders Englund; Carina Blomström-Lundqvist; Lars O Karlsson; Göran Kennebäck; Dritan Poçi; Romeo Samo-Ayou; Runa Sigurjónsdóttir; Michael Ringborn; Csaba Herczku; Jonas Carlson; Espen Fengsrud; Fariborz Tabrizi; Niklas Höglund; Stefan Lönnerholm; Ole Kongstad; Anders Jönsson; Per Insulander
Journal:  Eur Heart J       Date:  2019-03-07       Impact factor: 29.983

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.