Literature DB >> 24395586

Retrospective respiration-gated whole-body photoacoustic computed tomography of mice.

Jun Xia, Wanyi Chen, Konstantin Maslov, Mark A Anastasio, Lihong V Wang.   

Abstract

Photoacoustic tomography (PAT) is an emerging technique that has a great potential for preclinical whole-body imaging. To date, most whole-body PAT systems require multiple laser shots to generate one cross-sectional image, yielding a frame rate of <1  Hz. Because a mouse breathes at up to 3 Hz, without proper gating mechanisms, acquired images are susceptible to motion artifacts. Here, we introduce, for the first time to our knowledge, retrospective respiratory gating for whole-body photoacoustic computed tomography. This new method involves simultaneous capturing of the animal's respiratory waveform during photoacoustic data acquisition. The recorded photoacoustic signals are sorted and clustered according to the respiratory phase, and an image of the animal at each respiratory phase is reconstructed subsequently from the corresponding cluster. The new method was tested in a ring-shaped confocal photoacoustic computed tomography system with a hardware-limited frame rate of 0.625 Hz. After respiratory gating, we observed sharper vascular and anatomical images at different positions of the animal body. The entire breathing cycle can also be visualized at 20  frames/cycle.

Entities:  

Mesh:

Year:  2014        PMID: 24395586      PMCID: PMC3881607          DOI: 10.1117/1.JBO.19.1.016003

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  17 in total

1.  Effects of respiratory motion on dose uniformity with a charged particle scanning method.

Authors:  M H Phillips; E Pedroni; H Blattmann; T Boehringer; A Coray; S Scheib
Journal:  Phys Med Biol       Date:  1992-01       Impact factor: 3.609

2.  In vivo respiratory-gated micro-CT imaging in small-animal oncology models.

Authors:  Dawn Cavanaugh; Evan Johnson; Roger E Price; Jonathan Kurie; Elizabeth L Travis; Dianna D Cody
Journal:  Mol Imaging       Date:  2004-01       Impact factor: 4.488

3.  A novel, non-invasive method of respiratory monitoring for use with stereotactic procedures.

Authors:  Daniel R Cleary; Ryan S Phillips; Michael Wallisch; Mary M Heinricher
Journal:  J Neurosci Methods       Date:  2012-07-04       Impact factor: 2.390

4.  Half-time image reconstruction in thermoacoustic tomography.

Authors:  Mark A Anastasio; Jin Zhang; Xiaochuan Pan; Yu Zou; Geng Ku; Lihong V Wang
Journal:  IEEE Trans Med Imaging       Date:  2005-02       Impact factor: 10.048

5.  Whole-body ring-shaped confocal photoacoustic computed tomography of small animals in vivo.

Authors:  Jun Xia; Muhammad R Chatni; Konstantin Maslov; Zijian Guo; Kun Wang; Mark Anastasio; Lihong V Wang
Journal:  J Biomed Opt       Date:  2012-05       Impact factor: 3.170

Review 6.  Photoacoustic tomography: in vivo imaging from organelles to organs.

Authors:  Lihong V Wang; Song Hu
Journal:  Science       Date:  2012-03-23       Impact factor: 47.728

7.  Deep-tissue photoacoustic tomography of a genetically encoded near-infrared fluorescent probe.

Authors:  Grigory S Filonov; Arie Krumholz; Jun Xia; Junjie Yao; Lihong V Wang; Vladislav V Verkhusha
Journal:  Angew Chem Int Ed Engl       Date:  2011-12-23       Impact factor: 15.336

8.  Airway injury resulting from repeated endotracheal intubation: Possible prevention strategies.

Authors:  Adebayo Oshodi; Kevin Dysart; Alison Cook; Elena Rodriguez; Yan Zhu; Thomas H Shaffer; Thomas L Miller
Journal:  Pediatr Crit Care Med       Date:  2011-01       Impact factor: 3.624

Review 9.  Small-animal whole-body photoacoustic tomography: a review.

Authors:  Jun Xia; Lihong V Wang
Journal:  IEEE Trans Biomed Eng       Date:  2013-09-25       Impact factor: 4.538

10.  4-D photoacoustic tomography.

Authors:  Liangzhong Xiang; Bo Wang; Lijun Ji; Huabei Jiang
Journal:  Sci Rep       Date:  2013-01-23       Impact factor: 4.379

View more
  11 in total

1.  Photoacoustic tomography: principles and advances.

Authors:  Jun Xia; Junjie Yao; Lihong V Wang
Journal:  Electromagn Waves (Camb)       Date:  2014

2.  Errata: Lateral and axial measurement differences between spectral-domain optical coherence tomography systems.

Authors:  Francisco A Folgar; Eric L Yuan; Sina Farsiu; Cynthia A Toth
Journal:  J Biomed Opt       Date:  2015-05       Impact factor: 3.170

Review 3.  Tutorial on photoacoustic tomography.

Authors:  Yong Zhou; Junjie Yao; Lihong V Wang
Journal:  J Biomed Opt       Date:  2016-06       Impact factor: 3.170

4.  Listening to tissues with new light: recent technological advances in photoacoustic imaging.

Authors:  Tri Vu; Daniel Razansky; Junjie Yao
Journal:  J Opt       Date:  2019-09-09       Impact factor: 2.516

5.  Optical fiber-based handheld polarized photoacoustic computed tomography for detecting anisotropy of tissues.

Authors:  Yaguang Ren; Ying Zhang; Honghui He; Liangjian Liu; Xiaojun Wu; Liang Song; Chengbo Liu
Journal:  Quant Imaging Med Surg       Date:  2022-04

Review 6.  Structural and functional photoacoustic molecular tomography aided by emerging contrast agents.

Authors:  Liming Nie; Xiaoyuan Chen
Journal:  Chem Soc Rev       Date:  2014       Impact factor: 54.564

7.  Regional motion correction for in vivo photoacoustic imaging in humans using interleaved ultrasound images.

Authors:  Tobias Erlöv; Rafi Sheikh; Ulf Dahlstrand; John Albinsson; Malin Malmsjö; Magnus Cinthio
Journal:  Biomed Opt Express       Date:  2021-05-12       Impact factor: 3.732

8.  Motion correction in optoacoustic mesoscopy.

Authors:  Mathias Schwarz; Natalie Garzorz-Stark; Kilian Eyerich; Juan Aguirre; Vasilis Ntziachristos
Journal:  Sci Rep       Date:  2017-09-04       Impact factor: 4.379

9.  Tomographic breathing detection: a method to noninvasively assess in situ respiratory dynamics.

Authors:  Devin O'Kelly; Heling Zhou; Ralph P Mason
Journal:  J Biomed Opt       Date:  2018-05       Impact factor: 3.170

10.  Deep-learning-based motion-correction algorithm in optical resolution photoacoustic microscopy.

Authors:  Xingxing Chen; Weizhi Qi; Lei Xi
Journal:  Vis Comput Ind Biomed Art       Date:  2019-10-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.