Literature DB >> 1311106

Effects of respiratory motion on dose uniformity with a charged particle scanning method.

M H Phillips1, E Pedroni, H Blattmann, T Boehringer, A Coray, S Scheib.   

Abstract

A three-dimensional spot-scanning technique for radiotherapy with protons is being developed at the Paul Scherrer Institute. As part of the effort to optimize the design and ensure clinically useful dose distributions, a computer simulation of the dose deposition in the presence of respiratory motion was performed. Preliminary experiments have characterized the proton beam and the scanning procedure. Using these parameters, the computer program calculated the dose within a uniform volume of water in the presence of respiratory motion. Respiration amplitude, respiration period, respiration direction, number of fractions, size and position of the beamspots and rescanning multiplicity were systematically varied and the effect on the dose distribution determined. The dose uniformity is very dependent on the direction of the respiration relative to the three independent beam scanning directions. The dose uniformity decreases with increasing respiration amplitude, but has little response to changes in respiration frequency. Rescanning the volume, such as with fractionation, improves the dose uniformity roughly as the square root of the number of fractions. Broad, Gaussian beams result in better dose uniformity than narrow, sharply delineated ones, but produce slower dose fall-off at the edges of the scanned volume. Results of this work are being incorporated into the design of the system.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1311106     DOI: 10.1088/0031-9155/37/1/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  45 in total

1.  Motion mitigation for lung cancer patients treated with active scanning proton therapy.

Authors:  Clemens Grassberger; Stephen Dowdell; Greg Sharp; Harald Paganetti
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

2.  Four-dimensional layer-stacking carbon-ion beam dose distribution by use of a lung numeric phantom.

Authors:  Shinichiro Mori; Motoki Kumagai; Kentaro Miki
Journal:  Radiol Phys Technol       Date:  2015-04-02

3.  Gating window dependency on scanned carbon-ion beam dose distribution and imaging dose for thoracoabdominal treatment.

Authors:  Shinichiro Mori; Masataka Karube; Shigeo Yasuda; Naoyoshi Yamamoto; Hiroshi Tsuji; Tadashi Kamada
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

Review 4.  Treatment planning optimisation in proton therapy.

Authors:  S E McGowan; N G Burnet; A J Lomax
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

Review 5.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19

6.  Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence.

Authors:  Heng Li; X Ronald Zhu; Xiaodong Zhang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-06-18       Impact factor: 7.038

7.  Evaluation and mitigation of the interplay effects of intensity modulated proton therapy for lung cancer in a clinical setting.

Authors:  Laleh Kardar; Yupeng Li; Xiaoqiang Li; Heng Li; Wenhua Cao; Joe Y Chang; Li Liao; Ronald X Zhu; Narayan Sahoo; Michael Gillin; Zhongxing Liao; Ritsuko Komaki; James D Cox; Gino Lim; Xiaodong Zhang
Journal:  Pract Radiat Oncol       Date:  2014-08-12

8.  Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer.

Authors:  Wei Liu; Steven E Schild; Joe Y Chang; Zhongxing Liao; Yu-Hui Chang; Zhifei Wen; Jiajian Shen; Joshua B Stoker; Xiaoning Ding; Yanle Hu; Narayan Sahoo; Michael G Herman; Carlos Vargas; Sameer Keole; William Wong; Martin Bues
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-11-10       Impact factor: 7.038

9.  Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer.

Authors:  Chenbin Liu; Steven E Schild; Joe Y Chang; Zhongxing Liao; Shawn Korte; Jiajian Shen; Xiaoning Ding; Yanle Hu; Yixiu Kang; Sameer R Keole; Terence T Sio; William W Wong; Narayan Sahoo; Martin Bues; Wei Liu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-02-14       Impact factor: 7.038

10.  Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters.

Authors:  S Dowdell; C Grassberger; G C Sharp; H Paganetti
Journal:  Phys Med Biol       Date:  2013-05-20       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.