Literature DB >> 24390159

AFFINE-CORRECTED PARADISE: FREE-BREATHING PATIENT-ADAPTIVE CARDIAC MRI WITH SENSITIVITY ENCODING.

Behzad Sharif1, Yoram Bresler1.   

Abstract

We propose a real-time cardiac imaging method with parallel MRI that allows for free breathing during imaging and does not require cardiac or respiratory gating. The method is based on the recently proposed PARADISE (Patient-Adaptive Reconstruction and Acquisition Dynamic Imaging with Sensitivity Encoding) scheme. The new acquisition method adapts the PARADISE k-t space sampling pattern according to an affine model of the respiratory motion. The reconstruction scheme involves multi-channel time-sequential imaging with time-varying channels. All model parameters are adapted to the imaged patient as part of the experiment and drive both data acquisition and cine reconstruction. Simulated cardiac MRI experiments using the realistic NCAT phantom show high quality cine reconstructions and robustness to modeling inaccuracies.

Entities:  

Keywords:  Adaptive Acquisition; Affine Motion Correction; Dynamic MRI; Respiratory Motion; Time-Sequential Sampling

Year:  2007        PMID: 24390159      PMCID: PMC3879137          DOI: 10.1109/ISBI.2007.357042

Source DB:  PubMed          Journal:  Proc IEEE Int Symp Biomed Imaging        ISSN: 1945-7928


  4 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  A study of the motion and deformation of the heart due to respiration.

Authors:  Kate McLeish; Derek L G Hill; David Atkinson; Jane M Blackall; Reza Razavi
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

3.  Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model.

Authors:  Dirk Manke; Kay Nehrke; Peter Börnert
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

4.  OPTIMAL MULTI-CHANNEL TIME-SEQUENTIAL ACQUISITION IN DYNAMIC MRI WITH PARALLEL COILS.

Authors:  Behzad Sharif; Yoram Bresler
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2006
  4 in total
  3 in total

Review 1.  Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond.

Authors:  W Paul Segars; B M W Tsui; George S K Fung; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2017-08-10       Impact factor: 10.048

2.  Four-dimensional MRI using three-dimensional radial sampling with respiratory self-gating to characterize temporal phase-resolved respiratory motion in the abdomen.

Authors:  Zixin Deng; Jianing Pang; Wensha Yang; Yong Yue; Behzad Sharif; Richard Tuli; Debiao Li; Benedick Fraass; Zhaoyang Fan
Journal:  Magn Reson Med       Date:  2015-05-14       Impact factor: 4.668

3.  ECG and navigator-free four-dimensional whole-heart coronary MRA for simultaneous visualization of cardiac anatomy and function.

Authors:  Jianing Pang; Behzad Sharif; Zhaoyang Fan; Xiaoming Bi; Reza Arsanjani; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-09-12       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.