Literature DB >> 12815687

Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model.

Dirk Manke1, Kay Nehrke, Peter Börnert.   

Abstract

A novel technique is presented which enables the calibration of a 3D affine respiratory motion model to the individual motion pattern of the patient. The concept of multiple navigators and precursory navigators is introduced to address nonlinear properties and hysteresis effects of the model parameters with respect to the conventional diaphragmatic navigator. The optimal combination and weighting of the navigators is determined on the basis of a principal component analysis (PCA). Thus, based on a given navigator measurement the current motion state of the object can be predicted by means of the calibrated motion model. The 3D motion model is applied in high-resolution coronary MR angiography examinations (CMRA) to prospectively correct for respiration-induced motion. The basic feasibility of the proposed calibration procedure was shown in 16 volunteers. Furthermore, the application of the calibrated motion model for CMRA examinations of the right coronary artery (RCA) was tested in 10 volunteers. The superiority of a calibrated 3D translation model over the conventional 1D translation model with a fixed correction factor and the potential of affine prospective motion correction for CMRA are demonstrated. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12815687     DOI: 10.1002/mrm.10483

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  A SHAPE-NAVIGATED IMAGE DEFORMATION MODEL FOR 4D LUNG RESPIRATORY MOTION ESTIMATION.

Authors:  Xiaoxiao Liu; Rohit R Saboo; Stephen M Pizer; Gig S Mageras
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-06-28

Review 2.  Cardiovascular magnetic resonance imaging of coronary atherothrombosis.

Authors:  W Yong Kim; Elmar Spuentrup; Arno Buecker; Warren J Manning; René M Botnar
Journal:  J Nucl Cardiol       Date:  2005 May-Jun       Impact factor: 5.952

3.  3D MR coronary angiography: optimization of the technique and preliminary results.

Authors:  Cosima Jahnke; Ingo Paetsch; Eike Nagel
Journal:  Int J Cardiovasc Imaging       Date:  2006 Jun-Aug       Impact factor: 2.357

4.  Rest period duration of the coronary arteries: implications for magnetic resonance coronary angiography.

Authors:  Guy Shechter; Jon R Resar; Elliot R McVeigh
Journal:  Med Phys       Date:  2005-01       Impact factor: 4.071

5.  Patient specific prospective respiratory motion correction for efficient, free-breathing cardiovascular MRI.

Authors:  Michael A Bush; Rizwan Ahmad; Ning Jin; Yingmin Liu; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2019-02-14       Impact factor: 4.668

6.  Compressed-sensing motion compensation (CosMo): a joint prospective-retrospective respiratory navigator for coronary MRI.

Authors:  Mehdi H Moghari; Mehmet Akçakaya; Alan O'Connor; Tamer A Basha; Michele Casanova; Douglas Stanton; Lois Goepfert; Kraig V Kissinger; Beth Goddu; Michael L Chuang; Vahid Tarokh; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2011-06-10       Impact factor: 4.668

7.  Free-breathing, motion-corrected, highly efficient whole heart T2 mapping at 3T with hybrid radial-cartesian trajectory.

Authors:  Hsin-Jung Yang; Behzad Sharif; Jianing Pang; Avinash Kali; Xiaoming Bi; Ivan Cokic; Debiao Li; Rohan Dharmakumar
Journal:  Magn Reson Med       Date:  2015-03-06       Impact factor: 4.668

Review 8.  Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis.

Authors:  Elmar Spuentrup; Rene M Botnar
Journal:  Eur Radiol       Date:  2005-08-25       Impact factor: 5.315

9.  Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectory.

Authors:  R Reeve Ingle; Holden H Wu; Nii Okai Addy; Joseph Y Cheng; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

10.  Shape-correlated Deformation Statistics for Respiratory Motion Prediction in 4D Lung.

Authors:  Xiaoxiao Liu; Ipek Oguz; Stephen M Pizer; Gig S Mageras
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-02-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.