Literature DB >> 24389685

Evaluation of advancing the standard valve dysfunction by multidetector-row CT.

Hideki Teshima1, Shigeaki Aoyagi, Tomohiro Ueda, Kazuyoshi Takagi, Takahiro Shojima, Hiroyuki Tanaka.   

Abstract

We evaluated the diagnostic usefulness of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve dysfunction (PVD) of an ATS valve. Twenty-four patients underwent MDCT following echocardiography and cineradiography. Echocardiography and cineradiography showed normal valve function in 17 patients and PVD in 7. PVD included aortic prosthetic valve obstruction in 4 patients, an aortic annular aneurysm with paraprosthetic regurgitation in one, and a blocked leaflet in the mitral position in 2. Among the 7 patients, 5 received reoperation after MDCT. MDCT revealed a subprosthetic mass in all 5 patients with PVD and in 4 patients with normal valve function in the aortic position. In addition to a subprosthetic mass, an annular aneurysm was found in one. Valvular masses were detected in 2 patients with mitral PVD. At reoperation, subprosthetic pannus in the aortic position was detected in 2 patients, subprosthetic pannus and annular aneurysm with paraprosthetic leaks in one, and mitral valve thrombosis in 2. These findings confirmed at reoperation matched to the findings observed on MDCT. The mean CT attenuation of the subprosthetic mass in 6 patients was 152 ± 12 HU and that of the subprosthetic pannus in 3 patients was 163 ± 17 HU. CT attenuation of the thrombus in the mitral valve in the 2 patients was 60 and 99 HU. Our study demonstrates that MDCT is a valuable and reliable diagnostic technique for PVD in an ATS valve and that MDCT may identify an abnormality causing PVD.

Entities:  

Mesh:

Year:  2014        PMID: 24389685     DOI: 10.1007/s10047-013-0751-z

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  18 in total

1.  Multi-detector row CT attenuation measurements: assessment of intra- and interscanner variability with an anthropomorphic body CT phantom.

Authors:  Bernard A Birnbaum; Nicole Hindman; Julie Lee; James S Babb
Journal:  Radiology       Date:  2007-01       Impact factor: 11.105

2.  Prosthetic valve obstruction: diagnostic usefulness of cineradiography and multidetector-row computed tomography.

Authors:  S Aoyagi; S Fukunaga; K Arinaga; T Shojima; T Ueda
Journal:  Thorac Cardiovasc Surg       Date:  2007-12       Impact factor: 1.827

3.  Role of MDCT in the evaluation of prosthetic heart valves.

Authors:  Murat Biteker; Sabahattin Gündüz; Mehmet Ozkan
Journal:  AJR Am J Roentgenol       Date:  2009-02       Impact factor: 3.959

4.  Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography--identification of subprosthetic pannus in the aortic position.

Authors:  Tomohiro Ueda; Hideki Teshima; Shuji Fukunaga; Shigeaki Aoyagi; Hiroyuki Tanaka
Journal:  Circ J       Date:  2012-10-19       Impact factor: 2.993

5.  Cineradiographic evaluation of ATS open pivot bileaflet valves.

Authors:  S Aoyagi; T Kawara; S Fukunaga; T Mizoguchi; Y Nishi; H Kawano; K Arinaga
Journal:  J Heart Valve Dis       Date:  1997-05

6.  Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findings.

Authors:  S E Girard; F A Miller; T A Orszulak; C J Mullany; S Montgomery; W D Edwards; H D Tazelaar; J F Malouf; A J Tajik
Journal:  J Am Coll Cardiol       Date:  2001-02       Impact factor: 24.094

7.  Mid-term results of valve replacement with the ATS valve: a seven-year follow up.

Authors:  Shigeaki Aoyagi; Hidetsugu Hori; Kazuhiro Yoshikawa; Koichi Arinaga; Shuji Fukunaga
Journal:  J Heart Valve Dis       Date:  2007-05

8.  Mechanical mitral valve thrombosis and giant left atrial thrombus: comparison of transesophageal echocardiography and 64-slice multidetector computed tomography.

Authors:  Sabahattin Gündüz; Mehmet Ozkan; Murat Biteker; Tahsin Güneysu
Journal:  Turk Kardiyol Dern Ars       Date:  2009-10

9.  Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parameters.

Authors:  J Barbetseas; S F Nagueh; C Pitsavos; P K Toutouzas; M A Quiñones; W A Zoghbi
Journal:  J Am Coll Cardiol       Date:  1998-11       Impact factor: 24.094

10.  Left atrial appendage thrombi in stroke patients: detection with two-phase cardiac CT angiography versus transesophageal echocardiography.

Authors:  Jin Hur; Young Jin Kim; Hye-Jeong Lee; Jong-Won Ha; Ji Hoe Heo; Eui-Young Choi; Chi-Young Shim; Tae Hoon Kim; Ji Eun Nam; Kyu Ok Choe; Byoung Wook Choi
Journal:  Radiology       Date:  2009-04-14       Impact factor: 11.105

View more
  3 in total

1.  A reoperation of thrombosed On-X valve detected by multidetector-row computed tomography.

Authors:  Hideki Teshima; Masahiko Ikebuchi; Toshikazu Sano; Yusuke Kinugasa; Ryuta Tai; Hiroyuki Irie
Journal:  J Artif Organs       Date:  2015-06-24       Impact factor: 1.731

Review 2.  Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

Authors:  Mohamed A Aladmawi; Claudio Pragliola; Olga Vriz; Domenico Galzerano
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

3.  Effects of pannus formation on the flow around a bileaflet mechanical heart valve.

Authors:  Woojin Kim; Haecheon Choi; Jihoon Kweon; Dong Hyun Yang; Young-Hak Kim
Journal:  PLoS One       Date:  2020-06-12       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.