Literature DB >> 11216982

Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findings.

S E Girard1, F A Miller, T A Orszulak, C J Mullany, S Montgomery, W D Edwards, H D Tazelaar, J F Malouf, A J Tajik.   

Abstract

OBJECTIVES: We sought to: 1) identify trends in the diagnostic testing of patients with prosthetic aortic valve (AVR) obstruction who undergo reoperation and 2) compare diagnostic test results with pathologic findings at surgery.
BACKGROUND: It is unclear whether Doppler transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) have reduced hemodynamic catheterization rates.
METHODS: We reviewed 92 consecutive cases ofAVR reoperation at a single center from 1989 to 1998, comparing 49 cases of mechanical AVR obstruction (group A) to 43 cases of bioprosthetic obstruction (group B). Preoperative Doppler TTE was performed in all cases.
RESULTS: In group A cases, there was a marginally significant trend towards lower catheterization rates for the Gorlin AVR area, from 36% in 1989 to 1990 to 10% in 1997 to 1998 (p = 0.07), but diagnostic TEE utilization (47% of cases) did not vary. The cause of mechanical AVR obstruction was pannus in 26 cases (53%), mismatch (P-PM) in 19 (39%) and thrombosis in 4 (8%). The mechanism (pannus/thrombus vs. mismatch) was identified in 10% by TTE and 49% by TEE (p < 0.001). In group B cases, hemodynamic catheterization rates (21%) and diagnostic TEE utilization (21%) did not vary with time. Obstruction was caused by structural degeneration in 37 cases (86%), thrombosis in 3 (7%), mismatch in 2 (5%) and pannus in 1 (2%). The mechanism was correctly identified in 63% by TTE and in 81% by TEE (p = 0.18).
CONCLUSIONS: Doppler TTE is the primary means to diagnose AVR obstruction; hemodynamic catheterization is not routinely needed. In unselected patients with mechanical AVR obstruction, TEE differentiation of pannus or thrombus from mismatch is challenging.

Entities:  

Mesh:

Year:  2001        PMID: 11216982     DOI: 10.1016/s0735-1097(00)01113-x

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  16 in total

Review 1.  Multislice computed tomography angiography in the diagnosis of cardiovascular disease: 3D visualizations.

Authors:  Zhonghua Sun
Journal:  Front Med       Date:  2011-10-02       Impact factor: 4.592

2.  The utility of computed tomography in the context of aortic valve disease.

Authors:  Gudrun M Feuchtner
Journal:  Int J Cardiovasc Imaging       Date:  2009-05-26       Impact factor: 2.357

3.  Limitations of multimodality imaging in the diagnosis of pannus formation in prosthetic aortic valve and review of the literature.

Authors:  Juan Bautista Soumoulou; Tomás Francisco Cianciulli; Andrea Zappi; Alberto Cozzarin; María Cristina Saccheri; Jorge Alberto Lax; Robert Guidoin; Ze Zhang
Journal:  World J Cardiol       Date:  2015-04-26

4.  Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis.

Authors:  Hyun Jung Koo; Hojin Ha; Joon-Won Kang; Jeong A Kim; Jae-Kwan Song; Hwa Jung Kim; Tae-Hwan Lim; Dong Hyun Yang
Journal:  Clin Res Cardiol       Date:  2018-02-19       Impact factor: 5.460

5.  A reoperation of thrombosed On-X valve detected by multidetector-row computed tomography.

Authors:  Hideki Teshima; Masahiko Ikebuchi; Toshikazu Sano; Yusuke Kinugasa; Ryuta Tai; Hiroyuki Irie
Journal:  J Artif Organs       Date:  2015-06-24       Impact factor: 1.731

6.  Evaluation of advancing the standard valve dysfunction by multidetector-row CT.

Authors:  Hideki Teshima; Shigeaki Aoyagi; Tomohiro Ueda; Kazuyoshi Takagi; Takahiro Shojima; Hiroyuki Tanaka
Journal:  J Artif Organs       Date:  2014-01-04       Impact factor: 1.731

Review 7.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

Review 8.  Mechanical valve obstruction: Review of diagnostic and treatment strategies.

Authors:  Jason Salamon; Jerson Munoz-Mendoza; Jared J Liebelt; Cynthia C Taub
Journal:  World J Cardiol       Date:  2015-12-26

9.  Artifact reduction strategies for prosthetic heart valve CT imaging.

Authors:  Jesse Habets; Petr Symersky; Tim Leiner; Bas A J M de Mol; Willem P Th M Mali; Ricardo P J Budde
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-05       Impact factor: 2.357

10.  Is the Peak-to-Mean Pressure Gradient Ratio Useful for Assessment of Aortic Valve Prosthesis Obstruction?

Authors:  Maryam Esmaeilzadeh; Ahmad Mirdamadi; Mozhgan Parsaee; Anita Sadeghpour; Majid Maleki; Hooman Bakhshandeh Abkenar
Journal:  J Tehran Heart Cent       Date:  2010-05-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.