Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography--identification of subprosthetic pannus in the aortic position.

Tomohiro Ueda1, Hideki Teshima, Shuji Fukunaga, Shigeaki Aoyagi, Hiroyuki Tanaka.   

Abstract

BACKGROUND: This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. METHODS AND
RESULTS: Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; P<0.0001).
CONCLUSIONS: MDCT can be used to clearly visualize subprosthetic pannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.

Entities:  

Mesh:

Year:  2012        PMID: 23079400     DOI: 10.1253/circj.cj-12-0290

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  12 in total

1.  Echocardiography Aided by Computed Tomography to Diagnose Obstructive Masses in Patients with Prosthetic Heart Valves.

Authors:  Macit Kalcik; Ahmet Guner; Sabahattin Gunduz; Mehmet Ozkan
Journal:  Tex Heart Inst J       Date:  2020-08-01

2.  Utility of cardiac computed tomography for evaluation of pannus in mechanical aortic valve.

Authors:  Young Joo Suh; Young Jin Kim; Sak Lee; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Byoung Wook Choi; Byung-Chul Chang
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-21       Impact factor: 2.357

3.  Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis.

Authors:  Hyun Jung Koo; Hojin Ha; Joon-Won Kang; Jeong A Kim; Jae-Kwan Song; Hwa Jung Kim; Tae-Hwan Lim; Dong Hyun Yang
Journal:  Clin Res Cardiol       Date:  2018-02-19       Impact factor: 5.460

4.  A reoperation of thrombosed On-X valve detected by multidetector-row computed tomography.

Authors:  Hideki Teshima; Masahiko Ikebuchi; Toshikazu Sano; Yusuke Kinugasa; Ryuta Tai; Hiroyuki Irie
Journal:  J Artif Organs       Date:  2015-06-24       Impact factor: 1.731

5.  Evaluation of advancing the standard valve dysfunction by multidetector-row CT.

Authors:  Hideki Teshima; Shigeaki Aoyagi; Tomohiro Ueda; Kazuyoshi Takagi; Takahiro Shojima; Hiroyuki Tanaka
Journal:  J Artif Organs       Date:  2014-01-04       Impact factor: 1.731

Review 6.  Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

Authors:  Mohamed A Aladmawi; Claudio Pragliola; Olga Vriz; Domenico Galzerano
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

7.  Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

Authors:  Wilco Tanis; Dominika Suchá; Ward Laufer; Jesse Habets; Lex A van Herwerden; Petr Symersky; Steven Chamuleau; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2014-12-14       Impact factor: 5.315

8.  Mechanical pulmonic valve thrombosis: expanding role of cardiac CT and multimodality imaging.

Authors:  Ahmed A Kolkailah; Talal Asif; Fady H Iskander; Javier Gomez-Valencia; Saurabh Malhotra
Journal:  Radiol Case Rep       Date:  2022-07-05

9.  Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types.

Authors:  Young Joo Suh; Young Jin Kim; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Dong Jin Im; Yun Jung Kim; Byoung Wook Choi
Journal:  Korean J Radiol       Date:  2015-08-21       Impact factor: 3.500

10.  Case report of successful low-dose, ultra-slow infusion thrombolysis of prosthetic mitral valve thrombosis in a high risk patient after redo-mitral valve replacement.

Authors:  Ioannis Kapos; Tobias Fuchs; Felix C Tanner
Journal:  Eur Heart J Case Rep       Date:  2020-03-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.