Literature DB >> 24376991

Comparison of dosimetric characteristics of physical and enhanced dynamic wedges.

Sathiyan Saminathan1, Ravikumar Manickam1, Sanjay S Supe1.   

Abstract

BACKGROUND: Wedge filters can be used as missing tissue compensators or wedge pairs to alter the shape of isodose curves so that two beams can be angled with a small hinge angle at a target volume without creating a hotspot. AIM: In this study the dosimetric properties of Varian Enhanced Dynamic Wedge (EDW) and physical wedges (PW) were analyzed and compared.
MATERIALS AND METHODS: Ionometric measurements of open field output factor, physical wedge output factor, physical wedge factor and EDW factor for photon beams were carried out. A 3D scanning water phantom was used to scan depth dose and profiles for open and PW fields. The 2D ionization matrix was used to measure profiles of physical and EDW wedges. The isodose curves of physical and EDW angles were obtained using a therapy verification film. RESULTS AND DISCUSSION: The PW output factors of photons were compared with the open field output factors. The physical and EDW factors were compared. The difference in percentage depth dose for open and PW fields was observed for both photon beams. The measured isodose plots for physical and EDW were compared.
CONCLUSION: The wedge field output factor increases with field size and wedge angle compared to that of the open field output factor. The number of MU to deliver a particular dose with the EDW field is less than that of the PW field due to a change in wedge factor. The dosimetric characteristics, like profile and isodose of EDW, closely match with that of the PW.

Entities:  

Keywords:  Enhanced dynamic wedge; Physical wedge; Profile; Wedge factor

Year:  2011        PMID: 24376991      PMCID: PMC3863232          DOI: 10.1016/j.rpor.2011.06.007

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  16 in total

1.  Comparison of dosimetric characteristics of Siemens virtual and physical wedges.

Authors:  X R Zhu; M T Gillin; P A Jursinic; F Lopez; D F Grimm; J J Rownd
Journal:  Med Phys       Date:  2000-10       Impact factor: 4.071

2.  Calculation of enhanced dynamic wedge factors for symmetric and asymmetric photon fields.

Authors:  J P Gibbons
Journal:  Med Phys       Date:  1998-08       Impact factor: 4.071

3.  Calculating dose distributions and wedge factors for photon treatment fields with dynamic wedges based on a convolution/superposition method.

Authors:  H H Liu; E C McCullough; T R Mackie
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

4.  Validation of a new virtual wedge model.

Authors:  G E Desobry; T J Waldron; I J Das
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

5.  Implementation of the Varian EDW into a commercial RTP system.

Authors:  A W Beavis; S J Weston; V J Whitton
Journal:  Phys Med Biol       Date:  1996-09       Impact factor: 3.609

6.  Variations in depth-dose data between open and wedge fields for 4-MV X-rays.

Authors:  W Sewchand; F M Khan; J Williamson
Journal:  Radiology       Date:  1978-06       Impact factor: 11.105

7.  Dosimetric parameters of enhanced dynamic wedge for treatment planning and verification.

Authors:  D D Leavitt; W L Lee; D K Gaffney; J H Moeller; J H O'Rear
Journal:  Med Dosim       Date:  1997       Impact factor: 1.482

8.  Dosimetry and clinical implementation of dynamic wedge.

Authors:  E E Klein; D A Low; A S Meigooni; J A Purdy
Journal:  Int J Radiat Oncol Biol Phys       Date:  1995-02-01       Impact factor: 7.038

9.  Enhanced dynamic wedge factors at off-axis points in asymmetric fields.

Authors:  K L Prado; S M Kirsner; R J Kudchadker; R E Steadham; R G Lane
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

10.  Performance evaluation and quality assurance of Varian enhanced dynamic wedges.

Authors:  Parham Alaei; Patrick D Higgins
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

View more
  6 in total

1.  Intraoperative radiation therapy, opportunities for clinical practice normalization: MEDTING, a scientific platform.

Authors:  Felipe A Calvo; Laura Alonso Murillo; Morena Sallabanda; Javier Martinez-Villanueva; Rafael Herranz; Claudio V Sole
Journal:  Rep Pract Oncol Radiother       Date:  2013-09-28

2.  Intraoperative radiation therapy opportunities for clinical practice normalization: Data recording and innovative development.

Authors:  Felipe A Calvo; Morena Sallabanda; Claudio V Sole; Carmen Gonzalez; Laura Alonso Murillo; Javier Martinez-Villanueva; Juan A Santos; Javier Serrano; Ana Alavrez; Jose Blanco; Ana Calin; Marina Gomez-Espi; Miguel Lozano; Rafael Herranz
Journal:  Rep Pract Oncol Radiother       Date:  2013-08-13

3.  Multienergetic verification of dynamic wedge angles in medical accelerators using multichannel linear array.

Authors:  Anna Kowalik; Marcin Litoborski
Journal:  Rep Pract Oncol Radiother       Date:  2013-05-23

4.  Comparison of dosimetric characteristics of physical wedge and enhanced dynamic wedge in inhomogeneous medium using Monte Carlo simulations.

Authors:  Seied Rabi Mahdavi; Atefeh Mahmoudi; Ghazale Geraily; Ahmad Mostaar; Golbarg Esmaili
Journal:  Rep Pract Oncol Radiother       Date:  2021-02-25

5.  Dosimetric Comparison of Treatment Plans Using Physical Wedge and Enhanced Dynamic Wedge for the Planning of Breast Radiotherapy.

Authors:  Zhenia Gopalakrishnan; Raghuram K Nair; P Raghukumar; B Sarin
Journal:  J Med Phys       Date:  2018 Jan-Mar

6.  Enhanced dynamic wedge output factors for Varian 2300CD and the case for a reference database.

Authors:  Christopher F Njeh
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.