Literature DB >> 11099193

Comparison of dosimetric characteristics of Siemens virtual and physical wedges.

X R Zhu1, M T Gillin, P A Jursinic, F Lopez, D F Grimm, J J Rownd.   

Abstract

Dosimetric properties of Virtual Wedge (VW) and physical wedge (PW) in 6 and 23 MV photon beams from a Siemens Primus linear accelerator, including wedge factors, depth doses, dose profiles, peripheral doses and surface doses, are compared. While there is a great difference in absolute values of wedge factors, VW factors (VWFs) and PW factors (PWFs) have a similar trend as a function of field size. PWFs have a stronger depth dependence than VWF due to beam hardening in PW fields. VW dose profiles in the wedge direction, in general, match very well with PW, except in the toe area of large wedge angles with large field sizes. Dose profiles in the nonwedge direction show a significant reduction in PW fields due to off-axis beam softening and oblique filtration. PW fields have significantly higher peripheral doses than open and VW fields. VW fields have similar surface doses as the open fields while PW fields have lower surface doses. Surface doses for both VW and PW increase with field size and slightly with wedge angle. For VW fields with wedge angles 45 degrees and less, the initial gap up to 3 cm is dosimetrically acceptable when compared to dose profiles of PW. VW fields in general use less monitor units than PW fields.

Entities:  

Mesh:

Year:  2000        PMID: 11099193     DOI: 10.1118/1.1312813

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Comparison of dosimetric characteristics of physical and enhanced dynamic wedges.

Authors:  Sathiyan Saminathan; Ravikumar Manickam; Sanjay S Supe
Journal:  Rep Pract Oncol Radiother       Date:  2011-08-15

2.  Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams.

Authors:  Hatice Bilge; Nurdan Ozbek; Murat Okutan; Aydin Cakir; Hilal Acar
Journal:  Jpn J Radiol       Date:  2010-02-26       Impact factor: 2.374

3.  Studying wedge factors and beam profiles for physical and enhanced dynamic wedges.

Authors:  Misbah Ahmad; Amjad Hussain; Wazir Muhammad; Syed Qaisar Abbas Rizvi
Journal:  J Med Phys       Date:  2010-01

4.  Comparison of dosimetric characteristics of Siemens virtual and physical wedges for ONCOR linear accelerator.

Authors:  Ehab M Attalla; H S Abo-Elenein; H Ammar; Ismail El-Desoky
Journal:  J Med Phys       Date:  2010-07

5.  The accuracy of dynamic wedge dose computation in the ADAC Pinnacle RTP system.

Authors:  H Shao; X Wu; C Luo; A Crooks; A Bernstein; A Markoe
Journal:  J Appl Clin Med Phys       Date:  2004-10-01       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.