Literature DB >> 24371240

Controlled clinical comparison of BacT/alert FA plus and FN plus blood culture media with BacT/alert FA and FN blood culture media.

T J Kirn1, S Mirrett, L B Reller, M P Weinstein.   

Abstract

New blood culture media containing antibiotic-binding polymeric beads have been developed for the BacT/Alert (bioMérieux, Inc., Durham, NC) blood culture system. To assess the performance of these new media, we compared the new BacT/Alert aerobic medium (FA Plus) with resins to BacT/Alert FA medium with activated charcoal and the new BacT/Alert anaerobic medium (FN Plus) to BacT/Alert FN medium at 3 tertiary care medical centers. Study bottle pairs were inoculated with a target volume of 6 to 10 ml of blood from adults and incubated in the BacT/Alert 3D blood culture instrument. In the FA Plus versus FA comparison, there were 1,507 study pairs. Among 170 isolates causing true bloodstream infections (BSIs), significantly more Staphylococcus aureus (P<0.001) and total microorganisms (P<0.01) grew in the FA Plus bottle than in the FA bottle. Fewer coagulase-negative staphylococcal (CoNS) contaminants grew in the FA Plus bottle than in the FA bottle (10 versus 22; P=0.05). In addition, growth was detected earlier in the FA Plus bottle than in the FA bottle (P<0.001). In the FN Plus versus FN comparison, there were 2,386 study pairs. Among 201 isolates causing true BSIs, significantly more S. aureus (P<0.001), CoNS (P<0.005), and total microorganisms (P<0.001) grew in the FN Plus bottle than in the FN bottle. Also, significantly more CoNS contaminants grew in the FN Plus bottle than in the FN bottle (P<0.001). Overall, microorganisms were detected earlier in the FN Plus than in the FN bottle (P<0.001). Medical technologists at all 3 study sites preferred the new media for Gram stain interpretation. We conclude that the FA Plus and FN Plus media provide improved and earlier detection of microorganisms compared with the FA and FN media and are preferable for Gram stain interpretation as well.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24371240      PMCID: PMC3957782          DOI: 10.1128/JCM.03063-13

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Use of simulated blood cultures for antibiotic effect on time to detection of the two blood culture systems BacT/ALERT and BACTEC 9240.

Authors:  E F Viganò; E Vasconi; C Agrappi; P Clerici; P Melloni
Journal:  New Microbiol       Date:  2004-07       Impact factor: 2.479

2.  Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.

Authors:  R Ziegler; I Johnscher; P Martus; D Lenhardt; H M Just
Journal:  J Clin Microbiol       Date:  1998-03       Impact factor: 5.948

3.  Comparison of 2 blood culture media shows significant differences in bacterial recovery for patients on antimicrobial therapy.

Authors:  Rebecca Zadroga; David N Williams; Richard Gottschall; Kevan Hanson; Vickie Nordberg; Marcia Deike; Mike Kuskowski; Lisa Carlson; David P Nicolau; Christina Sutherland; Glen T Hansen
Journal:  Clin Infect Dis       Date:  2012-12-07       Impact factor: 9.079

4.  Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles.

Authors:  M P Weinstein; S Mirrett; M L Wilson; L J Harrell; C W Stratton; L B Reller
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

5.  Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia.

Authors:  J H Jorgensen; S Mirrett; L C McDonald; P R Murray; M P Weinstein; J Fune; C W Trippy; M Masterson; L B Reller
Journal:  J Clin Microbiol       Date:  1997-01       Impact factor: 5.948

6.  Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L G Reimer; M L Wilson; S Smith-Elekes; C R Chuard; K L Joho; L B Reller
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

7.  Comparison of BACTEC PLUS blood culture media to BacT/Alert FA blood culture media for detection of bacterial pathogens in samples containing therapeutic levels of antibiotics.

Authors:  Diane Flayhart; Anita P Borek; Teresa Wakefield; James Dick; Karen C Carroll
Journal:  J Clin Microbiol       Date:  2006-12-13       Impact factor: 5.948

8.  The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations.

Authors:  M P Weinstein; L B Reller; J R Murphy; K A Lichtenstein
Journal:  Rev Infect Dis       Date:  1983 Jan-Feb

9.  Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert Aerobic FAN bottles for detection of bloodstream infections.

Authors:  J K Pohlman; B A Kirkley; K A Easley; B A Basille; J A Washington
Journal:  J Clin Microbiol       Date:  1995-11       Impact factor: 5.948

10.  Controlled evaluation of BACTEC PLUS 27 and Roche Septi-Chek anaerobic blood culture bottles.

Authors:  M L Wilson; L J Harrell; S Mirrett; M P Weinstein; C W Stratton; L B Reller
Journal:  J Clin Microbiol       Date:  1992-01       Impact factor: 5.948

View more
  21 in total

1.  Controlled Evaluation of the New BacT/Alert Virtuo Blood Culture System for Detection and Time to Detection of Bacteria and Yeasts.

Authors:  Osman Altun; Mohammed Almuhayawi; Petra Lüthje; Rubina Taha; Måns Ullberg; Volkan Özenci
Journal:  J Clin Microbiol       Date:  2016-02-03       Impact factor: 5.948

2.  High medical impact of implementing the new polymeric bead-based BacT/ALERT® FAPlus and FNPlus blood culture bottles in standard care.

Authors:  R Amarsy-Guerle; F Mougari; H Jacquier; J Oliary; H Benmansour; J Riahi; B Berçot; L Raskine; E Cambau
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-02-04       Impact factor: 3.267

3.  Time to Detection with BacT/Alert FA Plus Compared to BacT/Alert FA Blood Culture Media.

Authors:  A Nutman; S Fisher Even-Tsur; G Shapiro; T Braun; D Schwartz; Y Carmeli
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-06-07       Impact factor: 3.267

4.  Contribution of the BacT/Alert MB Mycobacterium bottle to bloodstream infection surveillance in Thailand: added yield for Burkholderia pseudomallei.

Authors:  Possawat Jorakate; Melissa Higdon; Anek Kaewpan; Sirirat Makprasert; Somkhit Yuenprakhon; Kittisak Tawisaid; Surang Dejsirilert; Toni Whistler; Henry C Baggett
Journal:  J Clin Microbiol       Date:  2015-01-14       Impact factor: 5.948

5.  Efficient Inactivation of Clinically Relevant Antimicrobial Drug Concentrations by BacT/Alert or Bactec Resin-Containing Media in Simulated Adult Blood Cultures.

Authors:  Teresa Spanu; Brunella Posteraro; Giulia Menchinelli; Flora Marzia Liotti; Liliana Giordano; Giulia De Angelis; Maurizio Sanguinetti
Journal:  Antimicrob Agents Chemother       Date:  2019-06-24       Impact factor: 5.191

6.  Antimicrobial binding and growth kinetics in BacT/ALERT® FA Plus and BACTEC® Aerobic/F Plus blood culture media.

Authors:  D Lovern; B Katzin; K Johnson; D Broadwell; E Miller; A Gates; P Deol; K Doing; A van Belkum; C Marshall; E Mathias; W M Dunne
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-09-10       Impact factor: 3.267

7.  Comparison of BacT/Alert FAN and FAN Plus Bottles with Conventional Medium for Culturing Cerebrospinal Fluid.

Authors:  In Young Yoo; Sejong Chun; Dong Joon Song; Hee Jae Huh; Nam Yong Lee
Journal:  J Clin Microbiol       Date:  2016-09-14       Impact factor: 5.948

8.  Performance of two resin-containing blood culture media in detection of bloodstream infections and in direct matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) broth assays for isolate identification: clinical comparison of the BacT/Alert Plus and Bactec Plus systems.

Authors:  Barbara Fiori; Tiziana D'Inzeo; Viviana Di Florio; Flavio De Maio; Giulia De Angelis; Alessia Giaquinto; Lara Campana; Eloisa Tanzarella; Mario Tumbarello; Massimo Antonelli; Maurizio Sanguinetti; Teresa Spanu
Journal:  J Clin Microbiol       Date:  2014-07-16       Impact factor: 5.948

9.  Real-World Evaluation of the Impact of Implementation of the Virtuo Blood Culture System in a Tertiary Care Hospital.

Authors:  Miguel A Chavez; Satish Munigala; Carey-Ann D Burnham; Melanie L Yarbrough; David K Warren
Journal:  J Clin Microbiol       Date:  2021-07-14       Impact factor: 5.948

10.  Comparison of Microorganism Detection and Time to Positivity in Pediatric and Standard Media from Three Major Commercial Continuously Monitored Blood Culture Systems.

Authors:  Melanie L Yarbrough; Meghan A Wallace; Carey-Ann D Burnham
Journal:  J Clin Microbiol       Date:  2021-06-18       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.