Spatial and temporal performance of 3D optical surface imaging for real-time head position tracking.

Rodney D Wiersma1, S L Tomarken, Zachary Grelewicz, Andrew H Belcher, Hyejoo Kang.   

Abstract

PURPOSE: The spatial and temporal tracking performance of a commercially available 3D optical surface imaging system is evaluated for its potential use in frameless stereotactic radiosurgery head tracking applications.
METHODS: Both 3D surface and infrared (IR) marker tracking were performed simultaneously on a head phantom mounted on an xyz motion stage and on four human subjects. To allow spatial and temporal comparison on human subjects, three points were simultaneously monitored, including the upper facial region (3D surface), a dental plate (IR markers), and upper forehead (IR markers).
RESULTS: For both static and dynamic phantom studies, the 3D surface tracker was found to have a root mean squared error (RMSE) of approximately 0.30 mm for region-of-interest (ROI) surface sizes greater than 1000 vertex points. Although, the processing period (1/fps) of the 3D surface system was found to linearly increase as a function of the number of ROI vertex points, the tracking accuracy was found to be independent of ROI size provided that the ROI was sufficiently large and contained features for registration. For human subjects, the RMSE between 3D surface tracking and IR marker tracking modalities was 0.22 mm left-right (x-axis), 0.44 mm superior-inferior (y-axis), 0.27 mm anterior-posterior (z-axis), 0.29° pitch (around x-axis), 0.18° roll (around y-axis), and 0.15° yaw (around z-axis).
CONCLUSIONS: 3D surface imaging has the potential to provide submillimeter level head motion tracking. This is provided that a highly accurate camera-to-LINAC frame of reference calibration can be performed and that the reference ROI is of sufficient size and contains suitable surface features for registration.

Entities:  

Mesh:

Year:  2013        PMID: 24320420     DOI: 10.1118/1.4823757

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery.

Authors:  Xinmin Liu; Andrew H Belcher; Zachary Grelewicz; Rodney D Wiersma
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

2.  Towards frameless maskless SRS through real-time 6DoF robotic motion compensation.

Authors:  Andrew H Belcher; Xinmin Liu; Steven Chmura; Kamil Yenice; Rodney D Wiersma
Journal:  Phys Med Biol       Date:  2017-11-13       Impact factor: 3.609

3.  Spatial and rotational quality assurance of 6DOF patient tracking systems.

Authors:  Andrew H Belcher; Xinmin Liu; Zachary Grelewicz; Rodney D Wiersma
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

4.  Improved frame-based estimation of head motion in PET brain imaging.

Authors:  J M Mukherjee; C Lindsay; A Mukherjee; P Olivier; L Shao; M A King; R Licho
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

5.  Technical Note: High temporal resolution characterization of gating response time.

Authors:  Rodney D Wiersma; Bradley P McCabe; Andrew H Belcher; Patrick J Jensen; Brett Smith; Bulent Aydogan
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

6.  Use of proximal operator graph solver for radiation therapy inverse treatment planning.

Authors:  Xinmin Liu; Charles Pelizzari; Andrew H Belcher; Zachary Grelewicz; Rodney D Wiersma
Journal:  Med Phys       Date:  2017-04       Impact factor: 4.071

7.  A conceptual study on real-time adaptive radiation therapy optimization through ultra-fast beamlet control.

Authors:  Rodney D Wiersma; Xinmin Liu
Journal:  Biomed Phys Eng Express       Date:  2019-08-30

8.  Development of a 6DOF robotic motion phantom for radiation therapy.

Authors:  Andrew H Belcher; Xinmin Liu; Zachary Grelewicz; Erik Pearson; Rodney D Wiersma
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

9.  Development and clinical evaluation of a simple optical method to detect and measure patient external motion.

Authors:  Benigno Barbés; Juan Diego Azcona; Elena Prieto; José Manuel de Foronda; Marina García; Javier Burguete
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

10.  Optical Surface Scanning for Patient Positioning in Radiation Therapy: A Prospective Analysis of 1902 Fractions.

Authors:  G Carl; D Reitz; S Schönecker; M Pazos; P Freislederer; M Reiner; F Alongi; M Niyazi; U Ganswindt; C Belka; S Corradini
Journal:  Technol Cancer Res Treat       Date:  2018-01-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.