Literature DB >> 24297999

Optimization of configuration parameters in a newly developed digital breast tomosynthesis system.

Hye-Suk Park1, Ye-Seul Kim, Hee-Joung Kim, Young-Wook Choi, Jae-Gu Choi.   

Abstract

The purpose of the present work was to investigate the effects of variable projection-view (PV) and angular dose (AD) distributions on the reconstructed image quality for improving microcalcification detection. The PV densities at central and peripheral sites were varied through the distribution of 21 PVs acquired over ± 25° angular range. To vary the AD distribution, 7 PVs in the central region were targeted with two, four and six times the peripheral dose, and the number of central PVs receiving four times the peripheral dose was increased from 3 to 11. The contrast-to-noise ratio (CNR) for in-focus plane quality and the full width at half maximum (FWHM) of artifact spread function (ASF) for resolution in the z-direction were used. Although the ASF improved with increasing PV densities at two peripheral sites, the CNRs were inferior to those obtained with other subsets. With increasing PV density in the central area, the vertical resolution decreased but the CNR increased. Although increasing the central PV or AD concentrations improved image quality, excessive central densities reduced image quality by increasing noise in peripheral views.

Entities:  

Keywords:  angular dose distribution; digital breast tomosynthesis; microcalcification; projection view distribution

Mesh:

Year:  2013        PMID: 24297999      PMCID: PMC4014153          DOI: 10.1093/jrr/rrt130

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  18 in total

Review 1.  Clinical practice. Mammographic screening for breast cancer.

Authors:  Suzanne W Fletcher; Joann G Elmore
Journal:  N Engl J Med       Date:  2003-04-24       Impact factor: 91.245

2.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  A comparison of reconstruction algorithms for breast tomosynthesis.

Authors:  Tao Wu; Richard H Moore; Elizabeth A Rafferty; Daniel B Kopans
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

4.  Computation of the glandular radiation dose in digital tomosynthesis of the breast.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl D'Orsi; Andrew Karellas
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

5.  Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis.

Authors:  James G Mainprize; Aili K Bloomquist; Michael P Kempston; Martin J Yaffe
Journal:  Med Phys       Date:  2006-09       Impact factor: 4.071

6.  A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis.

Authors:  Yiheng Zhang; Heang-Ping Chan; Berkman Sahiner; Jun Wei; Mitchell M Goodsitt; Lubomir M Hadjiiski; Jun Ge; Chuan Zhou
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

7.  Three-dimensional linear system analysis for breast tomosynthesis.

Authors:  Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  Optimized image acquisition for breast tomosynthesis in projection and reconstruction space.

Authors:  Amarpreet S Chawla; Joseph Y Lo; Jay A Baker; Ehsan Samei
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

9.  AAPM/RSNA physics tutorial for residents: digital mammography: an overview.

Authors:  Mahadevappa Mahesh
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

10.  Beyond randomized controlled trials: organized mammographic screening substantially reduces breast carcinoma mortality.

Authors:  L Tabár; B Vitak; H H Chen; M F Yen; S W Duffy; R A Smith
Journal:  Cancer       Date:  2001-05-01       Impact factor: 6.860

View more
  1 in total

1.  Comparison study of reconstruction algorithms for prototype digital breast tomosynthesis using various breast phantoms.

Authors:  Ye-seul Kim; Hye-suk Park; Haeng-Hwa Lee; Young-Wook Choi; Jae-Gu Choi; Hak Hee Kim; Hee-Joung Kim
Journal:  Radiol Med       Date:  2015-09-18       Impact factor: 3.469

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.