Literature DB >> 24250967

The twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.

Ahmad Separham1, Bahram Sohrabi, Naser Aslanabadi, Samad Ghaffari.   

Abstract

INTRODUCTION: Drug-eluting stents (DES) have significantly decreased the need for repeat coronary revascularization but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with an everolimus-eluting stent (with durable polymer) one.
METHODS: We performed a randomized trial to compare the two types of stents. Two hundred patients undergoing PCI for de novo lesions were randomly assigned 1:1 to treatment with either biolimus-eluting (BioMatrix) or everolimus -eluting (Xience V) stent. The primary endpoint was a composite of cardiac death, myocardial infarction, and clinically driven target vessel revascularization within 12 months.
RESULTS: Demographics, clinical, and lesion characteristic were comparable between two groups. The 30-day major adverse car-diac event (MACE) rate was 2% in BioMatrix group versus 0% in Xience group (p > 0.05). After 12 months, the rates of cardiac death (0% in both groups), MI (2% versus 0%, p=0.49) and clinically -driven target vessel revascularization (0% in both groups) were similar for BioMatrix and Xience. No stent thrombosis was reported at 1, 6, 9 or 12 months after intervention in either group.
CONCLUSION: BES (Biolimus-eluting stent) with biodegradable polymer and EES (Everolimus-eluting stent) with durable polymer appear similar with respect to MACE and stent thrombosis in this patient population. Many studies with longer follow up are needed to define better the role of BES with biodegradable polymer in treatment of coronary artery lesions.

Entities:  

Keywords:  Biodegradable Polymer; Biolimus-Eluting Stent; Coronary Artery Disease; Everolimus -Eluting Stent; Revascularization

Year:  2011        PMID: 24250967      PMCID: PMC3825338          DOI: 10.5681/jcvtr.2011.025

Source DB:  PubMed          Journal:  J Cardiovasc Thorac Res        ISSN: 2008-5117


  10 in total

1.  The twelve-month outcomes of a biolimus eluting stent with a biodegradable polymer compared with a sirolimus eluting stent with a durable polymer.

Authors:  Scot Garg; Giovanna Sarno; Patrick W Serruys; Ton de Vries; Pawel Buszman; Axel Linke; Thomas Ischinger; Volker Klauss; Franz Eberli; Roberto Corti; William Wijns; Marie-Claude Morice; Carlo Di Mario; Robert Jan van Geuns; Pedro Eerdmans; Gerrit-Anne van Es; Bernhard Meier; Peter Jüni; Stephan Windecker
Journal:  EuroIntervention       Date:  2010-06       Impact factor: 6.534

Review 2.  Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern.

Authors:  Edoardo Camenzind; P Gabriel Steg; William Wijns
Journal:  Circulation       Date:  2007-03-07       Impact factor: 29.690

3.  Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial.

Authors:  Stephan Windecker; Patrick W Serruys; Simon Wandel; Pawel Buszman; Stanislaw Trznadel; Axel Linke; Karsten Lenk; Thomas Ischinger; Volker Klauss; Franz Eberli; Roberto Corti; William Wijns; Marie-Claude Morice; Carlo di Mario; Simon Davies; Robert-Jan van Geuns; Pedro Eerdmans; Gerrit-Anne van Es; Bernhard Meier; Peter Jüni
Journal:  Lancet       Date:  2008-08-31       Impact factor: 79.321

4.  Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk.

Authors:  Michael Joner; Aloke V Finn; Andrew Farb; Erik K Mont; Frank D Kolodgie; Elena Ladich; Robert Kutys; Kristi Skorija; Herman K Gold; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2006-05-05       Impact factor: 24.094

5.  3-year clinical follow-up of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery lesions: the SPIRIT II trial (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions).

Authors:  Scot Garg; Patrick Serruys; Yoshinobu Onuma; Cécile Dorange; Susan Veldhof; Karine Miquel-Hébert; Krishnankutty Sudhir; Jean Boland; Kurt Huber; Eulogio Garcia; Jan A M te Riele
Journal:  JACC Cardiovasc Interv       Date:  2009-12       Impact factor: 11.195

6.  Randomized comparison of everolimus-eluting and paclitaxel-eluting stents: two-year clinical follow-up from the Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions (SPIRIT) III trial.

Authors:  Gregg W Stone; Mark Midei; William Newman; Mark Sanz; James B Hermiller; Jerome Williams; Naim Farhat; Ronald Caputo; Nicholas Xenopoulos; Robert Applegate; Paul Gordon; Roseann M White; Krishnankutty Sudhir; Donald E Cutlip; John L Petersen
Journal:  Circulation       Date:  2009-01-26       Impact factor: 29.690

7.  Six-month results of a randomized study to evaluate safety and efficacy of a Biolimus A9 eluting stent with a biodegradable polymer coating.

Authors:  Eberhard Grube; Karl-Eugen Hauptmann; Lutz Buellesfeld; Victor Lim; Alex Abizaid
Journal:  EuroIntervention       Date:  2005-05       Impact factor: 6.534

8.  A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.

Authors:  Marie-Claude Morice; Patrick W Serruys; J Eduardo Sousa; Jean Fajadet; Ernesto Ban Hayashi; Marco Perin; Antonio Colombo; G Schuler; Paul Barragan; Giulio Guagliumi; Ferenc Molnàr; Robert Falotico
Journal:  N Engl J Med       Date:  2002-06-06       Impact factor: 91.245

9.  Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?

Authors:  Renu Virmani; Giulio Guagliumi; Andrew Farb; Giuseppe Musumeci; Niccolo Grieco; Teresio Motta; Laurian Mihalcsik; Maurizio Tespili; Orazio Valsecchi; Frank D Kolodgie
Journal:  Circulation       Date:  2004-01-26       Impact factor: 29.690

Review 10.  Next-generation drug-eluting stents in coronary artery disease: focus on everolimus-eluting stent (Xience V).

Authors:  Imad Sheiban; Gianluca Villata; Mario Bollati; Dario Sillano; Marzia Lotrionte; Giuseppe Biondi-Zoccai
Journal:  Vasc Health Risk Manag       Date:  2008
  10 in total
  8 in total

1.  Biodegradable polymer stents vs second generation drug eluting stents: A meta-analysis and systematic review of randomized controlled trials.

Authors:  Bhavi Pandya; Sainath Gaddam; Muhammad Raza; Deepak Asti; Nikhil Nalluri; Thomas Vazzana; Ruben Kandov; James Lafferty
Journal:  World J Cardiol       Date:  2016-02-26

2.  ABSORB BVS Implantation in Bifurcation Lesions - Current Evidence and Practical Recommendations.

Authors:  Robin P Kraak; Maik J Grundeken; Robbert J de Winter; Joanna J Wykrzykowska
Journal:  Interv Cardiol       Date:  2014-04

Review 3.  Adverse cardiovascular events associated with biodegradable polymer drug-eluting stents and durable polymer everolimus-eluting stents: A systematic review and meta-analysis of 10 randomized controlled trials.

Authors:  Pravesh Kumar Bundhun; Girish Janoo; Chandra Mouli Yanamala; Feng Huang
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

4.  Biodegradable polymer versus second-generation durable polymer drug-eluting stents in patients with coronary artery disease: A meta-analysis.

Authors:  James J Wu; Joshua A H Way; Probal Roy; Andy Yong; Harry Lowe; Leonard Kritharides; David Brieger
Journal:  Health Sci Rep       Date:  2018-10-05

5.  Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis.

Authors:  Eliano P Navarese; Kenneth Tandjung; Bimmer Claessen; Felicita Andreotti; Mariusz Kowalewski; David E Kandzari; Dean J Kereiakes; Ron Waksman; Laura Mauri; Ian T Meredith; Aloke V Finn; Hyo-Soo Kim; Jacek Kubica; Harry Suryapranata; Toni Mustahsani Aprami; Giuseppe Di Pasquale; Clemens von Birgelen; Elvin Kedhi
Journal:  BMJ       Date:  2013-11-06

6.  Safety and efficacy of biodegradable drug-eluting vs. bare metal stents: a meta-analysis from randomized trials.

Authors:  Yangguang Yin; Yao Zhang; Xiaohui Zhao
Journal:  PLoS One       Date:  2014-06-19       Impact factor: 3.240

Review 7.  Efficacy and safety of biodegradable polymer biolimus-eluting stents versus durable polymer drug-eluting stents: a meta-analysis.

Authors:  Yicong Ye; Hongzhi Xie; Yong Zeng; Xiliang Zhao; Zhuang Tian; Shuyang Zhang
Journal:  PLoS One       Date:  2013-11-11       Impact factor: 3.240

8.  Assessment of utility values and QALYs after primary PCI with DP-Xience and BP-Biomatrix stents.

Authors:  Salma Bibi; Amjad Khan; Asif Nadeem; Saima Mushtaq; Gul Majid Khan
Journal:  PLoS One       Date:  2021-06-17       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.