Literature DB >> 29588783

ABSORB BVS Implantation in Bifurcation Lesions - Current Evidence and Practical Recommendations.

Robin P Kraak1, Maik J Grundeken1, Robbert J de Winter1, Joanna J Wykrzykowska1.   

Abstract

The introduction of the ABSORB bioresorbable vascular scaffold (BVS) provides a new tool for stenting in interventional cardiology. Initially, relatively simple coronary artery lesions were treated with this novel device; nowadays, we are gaining clinical experience when treating a wide variety of lesions with the ABSORB BVS, including bifurcation lesions. Unfortunately, data are limited in terms of the use of the ABSORB BVS in coronary bifurcation lesions, so little is known about the safety and feasibility of these procedures. Bench testing and case reports showed that single provisional scaffold placement is feasible with fenestration of the scaffold towards the side branch and sequential non-compliant balloon inflation in the side and main branches. However, no prospective randomised clinical data with optical coherence tomography (OCT) imaging for different bifurcation stenting techniques are available. Based on the available data and our own experience we would recommend the use of the provisional single scaffold technique and only to fenestrate the scaffold if a severely pinched ostium combined with impaired flow seen on angiogram.

Entities:  

Keywords:  Percutaneous coronary interventions; bifurcation lesions; bioresorbable vascular scaffold; optical coherence tomography

Year:  2014        PMID: 29588783      PMCID: PMC5808623          DOI: 10.15420/icr.2011.9.2.84

Source DB:  PubMed          Journal:  Interv Cardiol        ISSN: 1756-1485


  27 in total

Review 1.  Design principles and performance of bioresorbable polymeric vascular scaffolds.

Authors:  James P Oberhauser; Syed Hossainy; Richard J Rapoza
Journal:  EuroIntervention       Date:  2009-12-15       Impact factor: 6.534

2.  A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods.

Authors:  Patrick W Serruys; John A Ormiston; Yoshinobu Onuma; Evelyn Regar; Nieves Gonzalo; Hector M Garcia-Garcia; Koen Nieman; Nico Bruining; Cécile Dorange; Karine Miquel-Hébert; Susan Veldhof; Mark Webster; Leif Thuesen; Dariusz Dudek
Journal:  Lancet       Date:  2009-03-14       Impact factor: 79.321

3.  The absorb bioresorbable vascular scaffold in coronary bifurcations: insights from bench testing.

Authors:  Vladimír Džavík; Antonio Colombo
Journal:  JACC Cardiovasc Interv       Date:  2013-12-11       Impact factor: 11.195

4.  Complex bifurcation percutaneous coronary intervention with the Absorb bioresorbable vascular scaffold.

Authors:  Vladimír Dzavík; Takashi Muramatsu; Noel Crooks; Shimpei Nakatani; Yoshinubu Onuma
Journal:  EuroIntervention       Date:  2013-11       Impact factor: 6.534

5.  Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk.

Authors:  Michael Joner; Aloke V Finn; Andrew Farb; Erik K Mont; Frank D Kolodgie; Elena Ladich; Robert Kutys; Kristi Skorija; Herman K Gold; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2006-05-05       Impact factor: 24.094

6.  Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease.

Authors:  Gregg W Stone; Ali Rizvi; William Newman; Kourosh Mastali; John C Wang; Ronald Caputo; Julie Doostzadeh; Sherry Cao; Charles A Simonton; Krishnankutty Sudhir; Alexandra J Lansky; Donald E Cutlip; Dean J Kereiakes
Journal:  N Engl J Med       Date:  2010-05-06       Impact factor: 91.245

Review 7.  Next-generation DES: the COMBO dual therapy stent with Genous endothelial progenitor capturing technology and an abluminal sirolimus matrix.

Authors:  Pier Woudstra; Robbert J de Winter; Marcel A Beijk
Journal:  Expert Rev Med Devices       Date:  2014-02-03       Impact factor: 3.166

8.  3D optical coherence tomography: new insights into the process of optimal rewiring of side branches during bifurcational stenting.

Authors:  Takayuki Okamura; Yoshinobu Onuma; Jutaro Yamada; Javaid Iqbal; Hiroki Tateishi; Tomoko Nao; Takamasa Oda; Takao Maeda; Takeshi Nakamura; Toshiro Miura; Masafumi Yano; Patrick W Serruys
Journal:  EuroIntervention       Date:  2014-12       Impact factor: 6.534

9.  The twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.

Authors:  Ahmad Separham; Bahram Sohrabi; Naser Aslanabadi; Samad Ghaffari
Journal:  J Cardiovasc Thorac Res       Date:  2011-12-28

10.  Effect of the endothelial shear stress patterns on neointimal proliferation following drug-eluting bioresorbable vascular scaffold implantation: an optical coherence tomography study.

Authors:  Christos V Bourantas; Michail I Papafaklis; Anna Kotsia; Vasim Farooq; Takashi Muramatsu; Josep Gomez-Lara; Yao-Jun Zhang; Javaid Iqbal; Fanis G Kalatzis; Katerina K Naka; Dimitrios I Fotiadis; Cecile Dorange; Jin Wang; Richard Rapoza; Hector M Garcia-Garcia; Yoshinobu Onuma; Lampros K Michalis; Patrick W Serruys
Journal:  JACC Cardiovasc Interv       Date:  2014-02-13       Impact factor: 11.195

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.