3-year clinical follow-up of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery lesions: the SPIRIT II trial (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions).

Scot Garg1, Patrick Serruys, Yoshinobu Onuma, Cécile Dorange, Susan Veldhof, Karine Miquel-Hébert, Krishnankutty Sudhir, Jean Boland, Kurt Huber, Eulogio Garcia, Jan A M te Riele.   

Abstract

OBJECTIVES: This paper reports the 3-year clinical outcomes of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) compared with the TAXUS (Boston Scientific, Natick, Massachusetts) paclitaxel-eluting stent (PES) in the randomized SPIRIT II (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions) study.
BACKGROUND: The Xience V EES is a new-generation drug-eluting stent (DES) that might offer advantages over the first-generation DES in terms of improved clinical outcomes and a better safety profile.
METHODS: The SPIRIT II trial was a multicenter, prospective, randomized, single-blind, clinical trial, randomizing 300 patients with de novo coronary artery lesions in a ratio of 3:1 to either EES or PES. The primary end point was in-stent late loss at 180 days.
RESULTS: At 3-year clinical follow-up cardiac death was numerically lower with EES than PES (0.5% vs. 4.3%, p = 0.056). The observed rate of myocardial infarction was 3.6% for EES and 7.2% for PES (p = 0.31). The rate of ischemia-driven target lesion revascularization was 4.6% and 10.1% for EES and PES, respectively (p = 0.14). Overall, there was a trend for lower major adverse cardiovascular events in the EES group compared with PES (7.2% vs. 15.9%, p = 0.053). The rate of stent thrombosis was low and comparable in both groups (EES 1.0% vs. PES 2.9%).
CONCLUSIONS: The present study reports the favorable 3-year clinical outcomes of the EES, which are consistent with the results from other studies of the EES with shorter follow-up.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20129545     DOI: 10.1016/j.jcin.2009.10.002

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  18 in total

1.  Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation.

Authors:  Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

2.  Long-term outcomes after a strategy of percutaneous coronary intervention of the infarct-related artery with drug-eluting stents or bare metal stents vs medical therapy alone in the Occluded Artery Trial (OAT).

Authors:  Xavier Freixa; Vladimír Džavík; Sandra A Forman; James M Rankin; Christopher E Buller; Warren J Cantor; Witold Ruzyllo; Harmony R Reynolds; Gervasio A Lamas; Judith S Hochman
Journal:  Am Heart J       Date:  2012-06       Impact factor: 4.749

3.  The twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.

Authors:  Ahmad Separham; Bahram Sohrabi; Naser Aslanabadi; Samad Ghaffari
Journal:  J Cardiovasc Thorac Res       Date:  2011-12-28

4.  Second- and third-generation drug-eluting coronary stents: progress and safety.

Authors:  I Akin; H Schneider; H Ince; S Kische; T C Rehders; T Chatterjee; C A Nienaber
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

5.  A first-in-man study of sirolimus-eluting, biodegradable polymer coated cobalt chromium stent in real life patients.

Authors:  Ashok Seth; Praveen Chandra; Nagendra S Chouhan; Ashok S Thakkar
Journal:  Indian Heart J       Date:  2012-07-27

Review 6.  The molecular mechanisms of congenital hypofibrinogenaemia.

Authors:  G J Maghzal; S O Brennan; V M Homer; P M George
Journal:  Cell Mol Life Sci       Date:  2004-06       Impact factor: 9.261

7.  A Randomized Comparison between Everolimus-Eluting Stent and Cobalt Chromium Stent in Patients with Acute ST-Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention Using Routine Intravenous Eptifibatide: The X-MAN (Xience vs. Multi-Link Stent in Acute Myocardial Infarction) Trial, A Pilot Study.

Authors:  Surya Dharma; Alexander J Wardeh; Sunarya Soerianata; Isman Firdaus; J Wouter Jukema
Journal:  Int J Angiol       Date:  2014-06

8.  Frequency of Vascular Inflammation and Impact on Neointimal Proliferation of Drug Eluting Stents in Porcine Coronary Arteries.

Authors:  Jong Shiuan Yeh; Seung Jin Oh; Chun Mei Hsueh
Journal:  Acta Cardiol Sin       Date:  2016-09       Impact factor: 2.672

9.  Everolimus-eluting stents: update on current clinical studies.

Authors:  Dominic J Allocco; Anita A Joshi; Keith D Dawkins
Journal:  Med Devices (Auckl)       Date:  2011-07-26

10.  Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22,844 patient years of follow-up from randomised trials.

Authors:  Sripal Bangalore; Sunil Kumar; Mario Fusaro; Nicholas Amoroso; Ajay J Kirtane; Robert A Byrne; David O Williams; James Slater; Donald E Cutlip; Frederick Feit
Journal:  BMJ       Date:  2012-08-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.