Literature DB >> 24203071

Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: A study of ion suppression.

D L Buhrman1, P I Price, P J Rudewiczcor.   

Abstract

The effect of coeluting matrix compounds on the quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry has been examined. During the method development stage of this assay, plasma samples spiked with the analyte at 100 pg/mL were extracted using three different procedures: a hexane liquid-liquid extraction, an ethyl acetate back-extraction, and a solid phase extraction. Ion intensity of the analyte was found to be related inversely to the percent ionization of coeluting matrix components as evidenced by full scan spectra. The ethyl acetate back-extraction, which contained the fewest coeluting components, resulted in the highest ion intensity for the analyte. An assay comparison was done by using the liquid-liquid hexane and the ethyl acetate back-extractions for sample preparation. Replicate 1-mL samples (n=5) at 11 concentrations from 5 to 2000 pg/mL were extracted and analyzed. The results for the ethyl acetate back-extracted samples were acceptable from 2000 to 5 pg/mL with accuracy ranging from -11.6 to 2.61% of the nominal concentrations. In contrast, the hexane liquid-liquid method had poor accuracy and precision below 20 pg/mL. The difference is explained by suppression of analyte ion intensity. These results are consistent with the current theory of electrospray ionization.

Entities:  

Year:  1996        PMID: 24203071     DOI: 10.1016/S1044-0305(96)00072-4

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  3 in total

1.  The sensitive determination of abanoquil in blood by high-performance liquid chromatography/atmospheric pressure ionization mass spectrometry.

Authors:  B Kaye; M W Clark; N J Cussans; P V Macrae; D A Stopher
Journal:  Biol Mass Spectrom       Date:  1992-11

2.  Determination of boldenone sulfoconjugate and related steroid sulfates in equine urine by high-performance liquid chromatography/tandem mass spectrometry.

Authors:  L O Weidolf; E D Lee; J D Henion
Journal:  Biomed Environ Mass Spectrom       Date:  1988-03-01

3.  Determination of xanomeline in human plasma by ion-spray tandem mass spectrometry.

Authors:  A T Murphy; P L Bonate; S C Kasper; T A Gillespie; A F DeLong
Journal:  Biol Mass Spectrom       Date:  1994-10
  3 in total
  28 in total

1.  High-throughput sample preparation and analysis using 96-well membrane solid-phase extraction and liquid chromatography-tandem mass spectrometry for the determination of steroids in human urine.

Authors:  G Rule; J Henion
Journal:  J Am Soc Mass Spectrom       Date:  1999-12       Impact factor: 3.109

2.  Mechanistic investigation of ionization suppression in electrospray ionization.

Authors:  R King; R Bonfiglio; C Fernandez-Metzler; C Miller-Stein; T Olah
Journal:  J Am Soc Mass Spectrom       Date:  2000-11       Impact factor: 3.109

3.  LC-MS/MS in the Clinical Laboratory - Where to From Here?

Authors:  Stefan Kg Grebe; Ravinder J Singh
Journal:  Clin Biochem Rev       Date:  2011-02

Review 4.  Mass spectrometry of structurally modified DNA.

Authors:  Natalia Tretyakova; Peter W Villalta; Srikanth Kotapati
Journal:  Chem Rev       Date:  2013-02-26       Impact factor: 60.622

Review 5.  Mass spectrometry as a quantitative tool in plant metabolomics.

Authors:  Tiago F Jorge; Ana T Mata; Carla António
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

6.  Targeted quantification of lipid mediators in skeletal muscles using restricted access media-based trap-and-elute liquid chromatography-mass spectrometry.

Authors:  Zhiying Wang; Liangqiao Bian; Chenglin Mo; Maciej Kukula; Kevin A Schug; Marco Brotto
Journal:  Anal Chim Acta       Date:  2017-07-14       Impact factor: 6.558

7.  A study of Pt(II)-phenanthroline complex interactions with double-stranded and G-quadruplex DNA by ESI-MS, circular dichroism, and computational docking.

Authors:  Dale L Ang; Celine Kelso; Jennifer L Beck; Stephen F Ralph; David G Harman; Janice R Aldrich-Wright
Journal:  J Biol Inorg Chem       Date:  2020-03-26       Impact factor: 3.358

8.  Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: influence of ionization type, sample preparation, and biofluid.

Authors:  Riet Dams; Marilyn A Huestis; Willy E Lambert; Constance M Murphy
Journal:  J Am Soc Mass Spectrom       Date:  2003-11       Impact factor: 3.109

9.  Development and validation of a high-performance liquid chromatography tandem mass spectrometry assay for atorvastatin, ortho-hydroxy atorvastatin, and para-hydroxy atorvastatin in human, dog, and rat plasma.

Authors:  W W Bullen; R A Miller; R N Hayes
Journal:  J Am Soc Mass Spectrom       Date:  1999-01       Impact factor: 3.109

10.  Quantitative hydrophilic interaction chromatography-mass spectrometry analysis of N-acetylneuraminic acid and N-acetylmannosamine in human plasma.

Authors:  Yifan Shi; Xin Xu; Meng Fang; Michael Zhang; Yinghe Li; Brad Gillespie; Selwyn Yorke; Nora Yang; John C McKew; William A Gahl; Marjan Huizing; Nuria Carrillo-Carrasco; Amy Qiu Wang
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2015-07-17       Impact factor: 3.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.