Literature DB >> 21451775

LC-MS/MS in the Clinical Laboratory - Where to From Here?

Stefan Kg Grebe1, Ravinder J Singh.   

Abstract

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in clinical laboratories during the last 10-15 years. It offers analytical specificity superior to that of immunoassays or conventional high performance/pressure liquid chromatography (HPLC) for low molecular weight analytes and has higher throughput than gas chromatography-mass spectrometry (GC-MS). Drug/Toxicology and Biochemical Genetics/Newborn Screening laboratories were at the vanguard of clinical LC-MS/MS use, but have been eclipsed by Endocrine laboratories. In USA reference/referral laboratories, most steroids and biogenic amines are now assayed by LC-MS/MS, and the technology has started to penetrate into smaller laboratories. Assays for mineralo- and gluco-corticoids and their precursors, sex steroids, metanephrines and 25-hydroxy vitamin D highlight the advantages of LC-MS/MS.However, several limitations of LC-MS/MS have become apparent, centring on the interacting triangle of sensitivity - specificity - throughput. While sample throughput is higher than for conventional HPLC or GC-MS, it lags behind automated immunoassays. Techniques which improve throughput include direct sample injection, LC-multiplexing and samplemultiplexing. Measures to improve specificity and sensitivity include sample clean-up and optimising chromatography to avoid interferences and ion suppression due to sample-matrix components. Next generation instrumentation may offer additional benefits.The next challenge for clinical LC-MS/MS is peptide/protein analysis. The quest for multi-biomarker profiles for various diseases has largely failed, but targeted peptide and protein testing by LC-MS/MS, directed at analytical and clinical questions that need to be answered, is proving highly successful. We anticipate that this will result in similar growth of clinical protein/peptide LC-MS/MS as has been seen for low molecular weight applications.

Entities:  

Year:  2011        PMID: 21451775      PMCID: PMC3052391     

Source DB:  PubMed          Journal:  Clin Biochem Rev        ISSN: 0159-8090


  80 in total

1.  Determination of 17-hydroxyprogesterone in plasma by stable isotope dilution/benchtop liquid chromatography-tandem mass spectrometry.

Authors:  S A Wudy; M Hartmann; M Svoboda
Journal:  Horm Res       Date:  2000

2.  Liquid chromatography-tandem mass spectrometry analysis of urinary free cortisol.

Authors:  Mark M Kushnir; Alan L Rockwood; Gordon J Nelson; Alan H Terry; A Wayne Meikle
Journal:  Clin Chem       Date:  2003-06       Impact factor: 8.327

Review 3.  Ultrasensitive and quantitative analyses from combined separations-mass spectrometry for the characterization of proteomes.

Authors:  Richard D Smith; Yufeng Shen; Keqi Tang
Journal:  Acc Chem Res       Date:  2004-04       Impact factor: 22.384

4.  Simultaneous measurement of aldosterone and cortisol by high-performance liquid chromatography-tandem mass spectrometry: application to dehydration-rehydration studies.

Authors:  Paul J Taylor; Simon P van Rosendal; Jeff S Coombes; Richard D Gordon; Michael Stowasser
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2010-03-23       Impact factor: 3.205

5.  C-3 epimers can account for a significant proportion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status.

Authors:  Ravinder J Singh; Robert L Taylor; G Satyanarayana Reddy; Stefan K G Grebe
Journal:  J Clin Endocrinol Metab       Date:  2006-05-23       Impact factor: 5.958

6.  Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography-tandem mass spectrometry without derivatization.

Authors:  Tiedong Guo; Jianghong Gu; Offie P Soldin; Ravinder J Singh; Steven J Soldin
Journal:  Clin Biochem       Date:  2008-03-07       Impact factor: 3.281

7.  Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: A study of ion suppression.

Authors:  D L Buhrman; P I Price; P J Rudewiczcor
Journal:  J Am Soc Mass Spectrom       Date:  1996-11       Impact factor: 3.109

8.  Determination of cortisol in human plasma by stable isotope dilution mass spectrometry.

Authors:  Y Kasuya; T Furuta; N Hirota
Journal:  Biomed Environ Mass Spectrom       Date:  1988-10

9.  Measurement of plasma aldosterone by gas chromatography with electron capture detection.

Authors:  G L Nicolis; J L Gabrilove
Journal:  J Clin Endocrinol Metab       Date:  1969-12       Impact factor: 5.958

10.  Plasma free metanephrine measurement using automated online solid-phase extraction HPLC tandem mass spectrometry.

Authors:  Wilhelmina H A de Jong; Kendon S Graham; Jan C van der Molen; Thera P Links; Michael R Morris; H Alec Ross; Elisabeth G E de Vries; Ido P Kema
Journal:  Clin Chem       Date:  2007-09       Impact factor: 8.327

View more
  91 in total

1.  Automated Trapping Column Exchanger for High-Throughput Nanoflow Liquid Chromatography.

Authors:  Sandra E Spencer; Thomas N Corso; James G Bollinger; Clark M Henderson; Andrew N Hoofnagle; Michael J MacCoss
Journal:  Anal Chem       Date:  2017-01-30       Impact factor: 6.986

Review 2.  Fat-Soluble Vitamins: Clinical Indications and Current Challenges for Chromatographic Measurement.

Authors:  Ali A Albahrani; Ronda F Greaves
Journal:  Clin Biochem Rev       Date:  2016-02

3.  Diagnosis of Clostridium difficile infection using an UPLC-MS based metabolomics method.

Authors:  Pengcheng Zhou; Ning Zhou; Li Shao; Jianzhou Li; Sidi Liu; Xiujuan Meng; Juping Duan; Xinrui Xiong; Xun Huang; Yuhua Chen; Xuegong Fan; Yixiang Zheng; Shujuan Ma; Chunhui Li; Anhua Wu
Journal:  Metabolomics       Date:  2018-07-19       Impact factor: 4.290

Review 4.  The use of mass spectrometry for analysing metabolite biomarkers in epidemiology: methodological and statistical considerations for application to large numbers of biological samples.

Authors:  Mads V Lind; Otto I Savolainen; Alastair B Ross
Journal:  Eur J Epidemiol       Date:  2016-05-26       Impact factor: 8.082

Review 5.  Emerging applications of metabolomics in drug discovery and precision medicine.

Authors:  David S Wishart
Journal:  Nat Rev Drug Discov       Date:  2016-03-11       Impact factor: 84.694

6.  A high-throughput SAMDI-mass spectrometry assay for isocitrate dehydrogenase 1.

Authors:  Sarah E Anderson; Natalie S Fahey; Jungsoo Park; Patrick T O'Kane; Chad A Mirkin; Milan Mrksich
Journal:  Analyst       Date:  2020-04-16       Impact factor: 4.616

7.  3D Printed Microfluidic Devices for Microchip Electrophoresis of Preterm Birth Biomarkers.

Authors:  Michael J Beauchamp; Anna V Nielsen; Hua Gong; Gregory P Nordin; Adam T Woolley
Journal:  Anal Chem       Date:  2019-05-14       Impact factor: 6.986

Review 8.  Metabolomics Biomarkers for Precision Psychiatry.

Authors:  Pei-An Betty Shih
Journal:  Adv Exp Med Biol       Date:  2019       Impact factor: 2.622

9.  Uncovering biologically significant lipid isomers with liquid chromatography, ion mobility spectrometry and mass spectrometry.

Authors:  Jennifer E Kyle; Xing Zhang; Karl K Weitz; Matthew E Monroe; Yehia M Ibrahim; Ronald J Moore; Jeeyeon Cha; Xiaofei Sun; Erica S Lovelace; Jessica Wagoner; Stephen J Polyak; Thomas O Metz; Sudhansu K Dey; Richard D Smith; Kristin E Burnum-Johnson; Erin S Baker
Journal:  Analyst       Date:  2016-03-07       Impact factor: 4.616

10.  Exposure to UV Wavelengths in Sunlight Suppresses Immunity. To What Extent is UV-induced Vitamin D3 the Mediator Responsible?

Authors:  Prue H Hart; Shelley Gorman
Journal:  Clin Biochem Rev       Date:  2013-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.