The aim of the present study was to test the validity of the transthoracic electrical bioimpedance method PhysioFlow® to measure stroke volume in patients with chronic anemia. Stroke volume index (SVI), as well as cardiac index (CI) obtained by transthoracic electrical bioimpedance method and doppler echocardiography were compared in healthy subjects (n = 25) and patients with chronic anemia (i.e. mainly with sickle cell anemia; n = 32), at rest. While doppler echocardiography was able to detect difference in SVI between the two populations, the Physioflow® failed to detect any difference. Bland & Altman analyses have demonstrated no interchangeability between the two methods to assess CI and SVI in anemic patients and healthy subjects. While doppler echocardiography displayed a good concordance for SVI results with those obtained in the literature for anemic patients, the Physioflow® did not. Finally, in contrast to doppler echocardiography: 1) the CI obtained with the Physioflow® was not correlated with the hemoglobin level and 2) the stroke volume determined by the Physioflow® was highly influenced by body surface area. In conclusion, our findings indicate that the Physioflow® device is inaccurate for the measurement of SVI and CI in patients with chronic anemia and has a poor accuracy for the measurement of these parameters in African healthy subjects.Entities:
Mesh:
Year: 2013 PMID: 24167637 PMCID: PMC3805528 DOI: 10.1371/journal.pone.0079086
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Characteristics of the two groups.
|
|
|
|
|
|
|
|
|
| |
|---|---|---|---|---|---|---|---|---|---|
|
| 25/0 | 24 ± 3 | 174 ± 5 | 65 ± 6 | 1.78 ± 0.10 | 14.4 ± 1.3 | 67 ± 7 | 121 ± 9 | 76 ± 8 |
|
| 28/4 | 26 ± 5 | 169 ± 10$ | 56 ± 10$$$ | 1.61 ± 0.18$$$ | 8.6 ± 1.4$$$ | 74 ± 11$$ | 116 ± 10 | 67 ± 9$$$ |
Means ± SD. Hb = Hemoglobin; HR = heart rate. Difference between healthy subjects and chronic anemic patients ($p<0.05, $$p<0.01; $$$p < 0.001).
Mean values of SVI in 10 healthy subjects measured during 4 consecutive days by doppler echocardiography and PhysioFlow® methods.
|
| |||||
|---|---|---|---|---|---|
|
|
|
|
|
| |
|
| 42 ± 5 | 44 ± 5 | 46 ± 6 | 44 ± 5 | 8.4 ± 3.8 |
|
| 44 ± 5 | 46 ± 5 | 49 ± 6 | 47 ± 5 | 5.7 ± 2.2 |
Means ± SD. SVI = stroke volume index; D1, D2, D3 and D4 = day1, 2, 3 and 4; CV = coefficient of variation.
Mean CI and SVI values measured by doppler echocardiograpgy and PhysioFlow® methods in healthy subjects and patients with chronic anemia.
|
|
| |||
|---|---|---|---|---|
|
|
|
|
| |
|
| 3.10 ± 0.42 | 2.98 ± 0.62 | 47 ± 6 | 44 ± 6 |
|
| 4.90 ± 0.99 $$ | 3.41 ± 0.76*** $ | 68 ± 12$$$ | 47 ± 9*** |
Means ± SD. CI = cardiac index; SVI = stroke volume index. Difference between doppler echocardiography and PhysioFlow (***p < 0.001); difference between healthy subjects and chronic anemic patients ($p<0.05, $$p<0.01; $$$p < 0.001).
Figure 1Correlation between CI (1A) or SVI (1B) measured by doppler echocardiography and determined by the PhysioFlow®.
Figure 2Bland and Altman analysis on CI and SVI determined by the two methods in the whole group (2A and 2B), the healthy subjects (2C and 2D) and the chronic anemic patients (2E and 2F).
Bland & Altman analysis results for assessment of intercheangeability between doppler echocardiograpgy and PhysioFlow® methods in healthy subjects, patients with chronic anemia and both groups.
|
|
|
|
|
| ||
|---|---|---|---|---|---|---|
|
|
| 0.1 (-0.1;0.4) | NS | -1.1 (-1.5;-0.6) | 1.3 (0.9;1.8) | 40% |
|
| 2.4 (-1.5;6.3) | NS | -16 (-22.7;-9.3) | 20.8 (14.1;27.5) | 40% | |
|
|
| 1.5 (1.1;1.9) | *** | -0.6 (-1.3;0.1) | 3.6 (2.9;4.3) | 54% |
|
| 20.6 (14.9;26.3) | *** | -10.2 (-20.0;-0.4) | 51.4 (41.6;61.2) | 54% | |
|
|
| 0.9 (0.6;1.2) | *** | -1.3 (-1.8;-0.8) | 3.1 (2.6;3.6) | 60% |
|
| 12.6 (8.4;18.9) | *** | -18.8 (-26.2;-11.5) | 44.1 (36.7;51.4) | 60% |
Means ± SD. NS = non significant; statistically different from 0 (***p < 0.001).
Figure 3Correlation between CI measured by doppler echocardiography (a) or determined by the PhysioFlow® (3B) and the hemoglobin (Hb) level.
Figure 4Effects of fictitious body surface area values on stroke volume (SV) measured by doppler echocardiography (4A) or by the PhysioFlow® (4B) in a given subject.
Comparisons between the CI and SVI values obtained in the present study with doppler echocardiography or PhysioFlow® and the values obtained in previous selected studies on healthy subjects.
|
|
|
|
|
|
| ||
|---|---|---|---|---|---|---|---|
|
|
|
|
| ||||
| Present study | Doppler echocardiography (n=25) | 3.1 ± 0.4 | 47 ± 6 | ||||
| Physioflow (n=25) | 3.0 ± 0.6 | 44 ± 6 | |||||
| [ | Indicator-dilution method (n=4) | 3.5 ± 0.2 | NS | NS | 54 ± 2 | * | * |
| [ | Indicator-dilution method (n=4) | 3.1 ± 0.4 | NS | NS | 50 ± 9 | NS | NS |
| [ | Fick method (n=11) | 3.2 ± 0.2 | NS | NS | 43 ± 2 | NS | NS |
| [ | Fick method (n=7) | 3.2 ± 0.4 | NS | NS | 43 ± 5 | NS | NS |
| [ | Bidimensional echocardiography (n=9) | - | - | - | 47 ± 2 | NS | NS |
| [ | Indicator-dilution method (n=4) | 3.5 ± 0.3 | NS | NS | 50 ± 5 | NS | NS |
| [ | Fick method (n=6) | 3.2 ± 0.3 | NS | NS | 46 ± 9 | NS | NS |
| [ | Bidimensional echocardiography (n=11) | 2.8 ± 0.8 | NS | NS | - | - | - |
| [ | Bidimensional echocardiography (n=7) | - | - | - | 42 ± 4 | * | NS |
| [ | Doppler echocardiography (n=30) | 3.6 ± 1.1 | NS | NS | - | - | - |
| [ | Doppler echocardiography (n=25) | 3.1 ± 0.9 | NS | NS | - | - | - |
| [ | Resonnance Magnetic Imaging (n=76) | - | - | - | 45 ± 9 | NS | NS |
Means ± SD. NS = non significant; statistical difference between the present study and previous study (*p < 0.05).
Comparisons between the CI and SVI values obtained in the present study with doppler echocardiography or PhysioFlow® and the values obtained in previous selected studies in patients with sickle cell anemia.
|
|
|
|
|
|
|
| ||
|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||
| Present study | Doppler echocardiography (n=32) | 8.6 ± 1.4 | 4.9 ± 1.0 | 67 ± 13 | ||||
| Physioflow (n=32) | 8.6 ± 1.4 | 3.4 ± 0.8 | 47 ± 9 | |||||
| [ | Fick method (n=12) | 7.9 ± 1.6 | 6.0 ± 0.8 | ** | *** | - | - | - |
| [ | Fick method (n=9) | 9.6 ± 2.0 | 4.2 ± 0.4 | NS | NS | - | - | - |
| [ | Fick method (n=7) | 7.5 ± 1.1 | 7.3 ± 2.6 | NS | NS | 77 ± 26 | NS | NS |
| [ | Bidimensional echocardiography (n=23) | - | - | - | - | 64 ± 14 | NS | * |
| [ | Fick method (n=39) | 8.2 ± 1.4 | 5.6 ± 0.2 | NS | *** | 69 ± 14 | NS | *** |
| [ | Cardiac scintigraphy (n=10) | 7.9 ± 1.1 | 4.9 ± 1.2 | NS | *** | 69 ± 20 | NS | NS |
| [ | Bidimensional echocardiography (n=11) | 7.9 ± ? | 4.7 ± 1.1 | NS | *** | - | - | - |
| [ | Doppler echocardiography (n=10) | 7.8 ± 0.6 | 5.5 ± 1.3 | NS | *** | 61 ± ? | - | - |
| [ | Bidimensional echocardiography (n=13) | 6.7 ± 1.0 | - | - | - | 58 ± 5 | NS | * |
| [ | Doppler echocardiography (n=40) | 8.9 ±1.7 | 4.8 ± 0.4 | NS | *** | - | - | - |
| [ | Doppler echocardiography (n=25) | - | 5.9 ± 1.8 | NS | * | _ | - | - |
Means ± SD. ? = not communicated by the authors; NS = non significant; statistical difference between the present study and previous study (*p < 0.05; **p < 0.01; ***p < 0.001).