Literature DB >> 16788385

Three types of skin-surface thermometers: a comparison of reliability, validity, and responsiveness.

Robert S Burnham1, Robert S McKinley, Daniel D Vincent.   

Abstract

OBJECTIVE: To compare the reliability, validity, and responsiveness of a thermistor thermometer (thermistor) and two different infrared thermometers (one designed to measure tympanic temperature and one for skin temperature).
DESIGN: Reliability and validity were evaluated by making two separate measurements from the skin at identical spots of each hand, forearm, shoulder, thigh, shin, and foot in 17 healthy subjects. Intramuscular temperature was recorded at the hand and shin sites. Test-retest reliability was calculated using intraclass correlation for each instrument. Pearson correlation assessed the relationship between the skin and intramuscular temperatures at the hand and shin sites (validity). Each instrument's ability to measure temperature change (responsiveness) was assessed by measuring skin temperatures serially from 17 limbs of ten patients with complex regional pain syndrome undergoing intravenous regional sympathetic blockade. Responsiveness index values were calculated.
RESULTS: Reliability was strong and similar for each device (intraclass correlation: thermistor = 0.96, tympanic = 0.96, skin = 0.97), as was validity (r: thermistor = 0.90, tympanic = 0.92, skin = 0.92). Responsiveness was marginally better for the infrared skin device (responsiveness index: skin = 4.2, tympanic = 3.6, thermistor = 3.6).
CONCLUSIONS: For the purposes of clinical electrodiagnostic laboratory and other physiatry applications, the performance of the infrared thermometers is equal to or superior to that of the traditionally used thermistor. All three devices are highly reliable and valid, whereas the infrared skin device is slightly more responsive. Infrared thermometers have the advantage of being quicker to operate and more portable.

Entities:  

Mesh:

Year:  2006        PMID: 16788385     DOI: 10.1097/01.phm.0000223232.32653.7f

Source DB:  PubMed          Journal:  Am J Phys Med Rehabil        ISSN: 0894-9115            Impact factor:   2.159


  17 in total

1.  Duration-dependant response of mixed-method pre-cooling for intermittent-sprint exercise in the heat.

Authors:  Geoffrey M Minett; Rob Duffield; Frank E Marino; Marc Portus
Journal:  Eur J Appl Physiol       Date:  2012-02-17       Impact factor: 3.078

2.  Bioharness(™) multivariable monitoring device: part. I: validity.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

3.  Bioharness(™) Multivariable Monitoring Device: Part. II: Reliability.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

4.  The Effect of Omega-3 Fatty Acid Supplementation on the Inflammatory Response to eccentric strength exercise.

Authors:  Kelly B Jouris; Jennifer L McDaniel; Edward P Weiss
Journal:  J Sports Sci Med       Date:  2011-09-01       Impact factor: 2.988

5.  Reliability of infrared thermography in skin temperature evaluation of wheelchair users.

Authors:  I Rossignoli; P J Benito; A J Herrero
Journal:  Spinal Cord       Date:  2014-11-25       Impact factor: 2.772

6.  Cold versus cold compression therapy after shoulder arthroscopy: a prospective randomized clinical trial.

Authors:  Martin Alfuth; Marion Strietzel; Tim Vogler; Dieter Rosenbaum; Dennis Liem
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-02-13       Impact factor: 4.342

7.  Effects of Short-Term Docosahexaenoic Acid Supplementation on Markers of Inflammation after Eccentric Strength Exercise in Women.

Authors:  Katherine E Corder; Katherine R Newsham; Jennifer L McDaniel; Uthayashanker R Ezekiel; Edward P Weiss
Journal:  J Sports Sci Med       Date:  2016-02-23       Impact factor: 2.988

8.  No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty.

Authors:  Ruud P van Hove; Richard M Brohet; Barend J van Royen; Peter A Nolte
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-05       Impact factor: 4.342

9.  A comparison between conductive and infrared devices for measuring mean skin temperature at rest, during exercise in the heat, and recovery.

Authors:  Aaron J E Bach; Ian B Stewart; Alice E Disher; Joseph T Costello
Journal:  PLoS One       Date:  2015-02-06       Impact factor: 3.240

10.  Lumbar sympathicolysis in patients with severe peripheral artery disease: hemodynamics of the lower limbs determined by near-infrared spectroscopy, color coded duplex sonography, and temperature measurement.

Authors:  Ingmar Bombor; Christian Wissgott; Reimer Andresen
Journal:  Clin Med Insights Cardiol       Date:  2015-03-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.