Revisit of combined parallel-beam/cone-beam or fan-beam/cone-beam imaging.

Gengsheng L Zeng1.   

Abstract

PURPOSE: This aim of this paper is to revisit the parallel-beam/cone-beam or fan-beam/cone-beam imaging configuration, and to investigate whether this configuration has any advantages.
METHODS: Twenty years ago, it was suggested to simultaneously use a parallel-beam (or a fan-beam) collimator and a cone-beam collimator to acquire single photon emission computed tomography data. The motivation was that the parallel-beam (or the fan-beam) collimator can provide sufficient sampling, while the cone-beam collimator is able to provide higher photon counts. Even with higher total counts, this hybrid system does not give significant improvement (if any) in terms of image noise and artifacts reduction. If a conventional iterative maximum-likelihood expectation-maximization algorithm is used to reconstruct the image, the resultant reconstruction may be worse than the parallel-beam-only (or fan-beam-only) system. This paper uses the singular value decomposition (SVD) analysis to explain this phenomenon.
RESULTS: The SVD results indicate that the parallel-beam-only and the fan-beam-only system outperform the combined systems.
CONCLUSIONS: The optimal imaging system does not necessary to be the one that generates the projections with highest signal-to-noise ratio and best resolution.

Entities:  

Mesh:

Year:  2013        PMID: 24089888      PMCID: PMC3785539          DOI: 10.1118/1.4820373

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  A novel three-dimensional image reconstruction method for near-field coded aperture single photon emission computerized tomography.

Authors:  Zhiping Mu; Baoming Hong; Shimin Li; Yi-Hwa Liu
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

2.  Three-dimensional SPECT reconstruction of combined cone beam and parallel beam data.

Authors:  R J Jaszczak; J Li; H Wang; R E Coleman
Journal:  Phys Med Biol       Date:  1992-03       Impact factor: 3.609

  2 in total
  2 in total

Review 1.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations.

Authors:  Yanfei Mao; Zhicong Yu; Gengsheng L Zeng
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.