Literature DB >> 19544769

A novel three-dimensional image reconstruction method for near-field coded aperture single photon emission computerized tomography.

Zhiping Mu1, Baoming Hong, Shimin Li, Yi-Hwa Liu.   

Abstract

Coded aperture imaging for two-dimensional (2D) planar objects has been investigated extensively in the past, whereas little success has been achieved in imaging 3D objects using this technique. In this article, the authors present a novel method of 3D single photon emission computerized tomography (SPECT) reconstruction for near-field coded aperture imaging. Multiangular coded aperture projections are acquired and a stack of 2D images is reconstructed separately from each of the projections. Secondary projections are subsequently generated from the reconstructed image stacks based on the geometry of parallel-hole collimation and the variable magnification of near-field coded aperture imaging. Sinograms of cross-sectional slices of 3D objects are assembled from the secondary projections, and the ordered subset expectation and maximization algorithm is employed to reconstruct the cross-sectional image slices from the sinograms. Experiments were conducted using a customized capillary tube phantom and a micro hot rod phantom. Imaged at approximately 50 cm from the detector, hot rods in the phantom with diameters as small as 2.4 mm could be discerned in the reconstructed SPECT images. These results have demonstrated the feasibility of the authors' 3D coded aperture image reconstruction algorithm for SPECT, representing an important step in their effort to develop a high sensitivity and high resolution SPECT imaging system.

Mesh:

Year:  2009        PMID: 19544769      PMCID: PMC2832028          DOI: 10.1118/1.3103490

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Uniformly redundant arrays: digital reconstruction methods.

Authors:  E E Fenimore; T M Cannon
Journal:  Appl Opt       Date:  1981-05-15       Impact factor: 1.980

2.  New family of binary arrays for coded aperture imaging.

Authors:  S R Gottesman; E E Fenimore
Journal:  Appl Opt       Date:  1989-10-15       Impact factor: 1.980

Review 3.  Small animal SPECT and its place in the matrix of molecular imaging technologies.

Authors:  Steven R Meikle; Peter Kench; Michael Kassiou; Richard B Banati
Journal:  Phys Med Biol       Date:  2005-10-24       Impact factor: 3.609

4.  Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging--a simulation study.

Authors:  Zixiong Cao; Girish Bal; Roberto Accorsi; Paul D Acton
Journal:  Phys Med Biol       Date:  2005-09-21       Impact factor: 3.609

5.  A multipinhole small animal SPECT system with submillimeter spatial resolution.

Authors:  Tobias Funk; Philippe Després; William C Barber; Kanai S Shah; Bruce H Hasegawa
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

6.  A new method for SPECT quantification of targeted radiotracers uptake in the myocardium.

Authors:  Shimin Li; Lawrence W Dobrucki; Albert J Sinusas; Yi-Hwa Liu
Journal:  Med Image Comput Comput Assist Interv       Date:  2005

7.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

8.  Coded aperture imaging with uniformly redundant arrays.

Authors:  E E Fenimore; T M Cannon
Journal:  Appl Opt       Date:  1978-02-01       Impact factor: 1.980

9.  Tomographical imaging using uniformly redundant arrays.

Authors:  T M Cannon; E E Fenimore
Journal:  Appl Opt       Date:  1979-04-01       Impact factor: 1.980

10.  99mTc-HL91: "hot spot" detection of ischemic myocardium in vivo by gamma camera imaging.

Authors:  R D Okada; G Johnson; K N Nguyen; Z Liu; B Edwards; C M Archer; T L North; A C King; J D Kelly
Journal:  Circulation       Date:  1998-06-30       Impact factor: 29.690

View more
  3 in total

1.  Revisit of combined parallel-beam/cone-beam or fan-beam/cone-beam imaging.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

2.  Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging.

Authors:  Katherine L Walker; Martin S Judenhofer; Simon R Cherry; Gregory S Mitchell
Journal:  Phys Med Biol       Date:  2014-12-12       Impact factor: 3.609

3.  SPECT Imaging of 2-D and 3-D Distributed Sources with Near-Field Coded Aperture Collimation: Computer Simulation and Real Data Validation.

Authors:  Zhiping Mu; Lawrence W Dobrucki; Yi-Hwa Liu
Journal:  J Med Biol Eng       Date:  2016-02-18       Impact factor: 1.553

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.