Literature DB >> 24077063

Accelerating free breathing myocardial perfusion MRI using multi coil radial k-t SLR.

Sajan Goud Lingala1, Edward DiBella, Ganesh Adluru, Christopher McGann, Mathews Jacob.   

Abstract

The clinical utility of myocardial perfusion MR imaging (MPI) is often restricted by the inability of current acquisition schemes to simultaneously achieve high spatio-temporal resolution, good volume coverage, and high signal to noise ratio. Moreover, many subjects often find it difficult to hold their breath for sufficiently long durations making it difficult to obtain reliable MPI data. Accelerated acquisition of free breathing MPI data can overcome some of these challenges. Recently, an algorithm termed as k - t SLR has been proposed to accelerate dynamic MRI by exploiting sparsity and low rank properties of dynamic MRI data. The main focus of this paper is to further improve k - t SLR and demonstrate its utility in considerably accelerating free breathing MPI. We extend its previous implementation to account for multi-coil radial MPI acquisitions. We perform k - t sampling experiments to compare different radial trajectories and determine the best sampling pattern. We also introduce a novel augmented Lagrangian framework to considerably improve the algorithm's convergence rate. The proposed algorithm is validated using free breathing rest and stress radial perfusion data sets from two normal subjects and one patient with ischemia. k - t SLR was observed to provide faithful reconstructions at high acceleration levels with minimal artifacts compared to existing MPI acceleration schemes such as spatio-temporal constrained reconstruction and k - t SPARSE/SENSE.

Entities:  

Mesh:

Year:  2013        PMID: 24077063      PMCID: PMC3902973          DOI: 10.1088/0031-9155/58/20/7309

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  24 in total

1.  Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI.

Authors:  Ricardo Otazo; Daniel Kim; Leon Axel; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

2.  Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE.

Authors:  P Kellman; J A Derbyshire; K O Agyeman; E R McVeigh; A E Arai
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Myocardial perfusion acquisition without magnetization preparation or gating.

Authors:  Edward V R DiBella; Liyong Chen; Matthias C Schabel; Ganesh Adluru; Chris J McGann
Journal:  Magn Reson Med       Date:  2011-12-21       Impact factor: 4.668

4.  Parallel MR image reconstruction using augmented Lagrangian methods.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2010-11-18       Impact factor: 10.048

5.  Video denoising, deblocking, and enhancement through separable 4-D nonlocal spatiotemporal transforms.

Authors:  Matteo Maggioni; Giacomo Boracchi; Alessandro Foi; Karen Egiazarian
Journal:  IEEE Trans Image Process       Date:  2012-05-15       Impact factor: 10.856

6.  k-t PCA: temporally constrained k-t BLAST reconstruction using principal component analysis.

Authors:  Henrik Pedersen; Sebastian Kozerke; Steffen Ringgaard; Kay Nehrke; Won Yong Kim
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

7.  Temporal filtering effects in dynamic parallel MRI.

Authors:  Martin Blaimer; Irene P Ponce; Felix A Breuer; Peter M Jakob; Mark A Griswold; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

8.  The influence of radial undersampling schemes on compressed sensing reconstruction in breast MRI.

Authors:  Rachel W Chan; Elizabeth A Ramsay; Edward Y Cheung; Donald B Plewes
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

9.  Three-dimensional first-pass myocardial perfusion MRI using a stack-of-spirals acquisition.

Authors:  Taehoon Shin; Krishna S Nayak; Juan M Santos; Dwight G Nishimura; Bob S Hu; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

10.  Acquisition and reconstruction of undersampled radial data for myocardial perfusion magnetic resonance imaging.

Authors:  Ganesh Adluru; Chris McGann; Peter Speier; Eugene G Kholmovski; Akram Shaaban; Edward V R Dibella
Journal:  J Magn Reson Imaging       Date:  2009-02       Impact factor: 4.813

View more
  17 in total

1.  Blind Compressed Sensing Enables 3-Dimensional Dynamic Free Breathing Magnetic Resonance Imaging of Lung Volumes and Diaphragm Motion.

Authors:  Sampada Bhave; Sajan Goud Lingala; John D Newell; Scott K Nagle; Mathews Jacob
Journal:  Invest Radiol       Date:  2016-06       Impact factor: 6.016

2.  Subspace aware recovery of low rank and jointly sparse signals.

Authors:  Sampurna Biswas; Soura Dasgupta; Raghuraman Mudumbai; Mathews Jacob
Journal:  IEEE Trans Comput Imaging       Date:  2016-11-14

3.  Single-Shot Coronary Quiescent-Interval Slice-Selective Magnetic Resonance Angiography Using Compressed Sensing: A Feasibility Study in Patients With Congenital Heart Disease.

Authors:  Daming Shen; Robert R Edelman; Joshua D Robinson; Hassan Haji-Valizadeh; Marci Messina; Shivraman Giri; Ioannis Koktzoglou; Cynthia K Rigsby; Daniel Kim
Journal:  J Comput Assist Tomogr       Date:  2018 Sep/Oct       Impact factor: 1.826

4.  GRASP-Pro: imProving GRASP DCE-MRI through self-calibrating subspace-modeling and contrast phase automation.

Authors:  Li Feng; Qiuting Wen; Chenchan Huang; Angela Tong; Fang Liu; Hersh Chandarana
Journal:  Magn Reson Med       Date:  2019-08-10       Impact factor: 4.668

5.  First-pass myocardial perfusion MRI with reduced subendocardial dark-rim artifact using optimized Cartesian sampling.

Authors:  Zhengwei Zhou; Xiaoming Bi; Janet Wei; Hsin-Jung Yang; Rohan Dharmakumar; Reza Arsanjani; C Noel Bairey Merz; Debiao Li; Behzad Sharif
Journal:  J Magn Reson Imaging       Date:  2016-08-17       Impact factor: 4.813

6.  Deformation corrected compressed sensing (DC-CS): a novel framework for accelerated dynamic MRI.

Authors:  Sajan Goud Lingala; Edward DiBella; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2014-07-29       Impact factor: 10.048

7.  Split Bregman multicoil accelerated reconstruction technique: A new framework for rapid reconstruction of cardiac perfusion MRI.

Authors:  Srikant Kamesh Iyer; Tolga Tasdizen; Devavrat Likhite; Edward DiBella
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

Review 8.  Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption.

Authors:  Alice C Yang; Madison Kretzler; Sonja Sudarski; Vikas Gulani; Nicole Seiberlich
Journal:  Invest Radiol       Date:  2016-06       Impact factor: 6.016

9.  Accelerated Wideband Myocardial Perfusion Pulse Sequence with Compressed Sensing Reconstruction for Myocardial Blood Flow Quantification in Patients with a Cardiac Implantable Electronic Device.

Authors:  KyungPyo Hong; Jeremy D Collins; Benjamin H Freed; Lexiaozi Fan; Andrew E Arai; Li-Yueh Hsu; Daniel C Lee; Daniel Kim
Journal:  Radiol Cardiothorac Imaging       Date:  2020-04-16

10.  Quantification of myocardial perfusion with self-gated cardiovascular magnetic resonance.

Authors:  Devavrat Likhite; Ganesh Adluru; Nan Hu; Chris McGann; Edward DiBella
Journal:  J Cardiovasc Magn Reson       Date:  2015-02-12       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.