Literature DB >> 27532501

First-pass myocardial perfusion MRI with reduced subendocardial dark-rim artifact using optimized Cartesian sampling.

Zhengwei Zhou1,2, Xiaoming Bi3, Janet Wei1,4,5, Hsin-Jung Yang1,2, Rohan Dharmakumar1,4,5, Reza Arsanjani1,5, C Noel Bairey Merz4,5, Debiao Li1,2,4, Behzad Sharif1,4.   

Abstract

PURPOSE: The presence of subendocardial dark-rim artifact (DRA) remains an ongoing challenge in first-pass perfusion (FPP) cardiac magnetic resonance imaging (MRI). We propose a free-breathing FPP imaging scheme with Cartesian sampling that is optimized to minimize the DRA and readily enables near-instantaneous image reconstruction.
MATERIALS AND METHODS: The proposed FPP method suppresses Gibbs ringing effects-a major underlying factor for the DRA-by "shaping" the underlying point spread function through a two-step process: 1) an undersampled Cartesian sampling scheme that widens the k-space coverage compared to the conventional scheme; and 2) a modified parallel-imaging scheme that incorporates optimized apodization (k-space data filtering) to suppress Gibbs-ringing effects. Healthy volunteer studies (n = 10) were performed to compare the proposed method against the conventional Cartesian technique-both using a saturation-recovery gradient-echo sequence at 3T. Furthermore, FPP imaging studies using the proposed method were performed in infarcted canines (n = 3), and in two symptomatic patients with suspected coronary microvascular dysfunction for assessment of myocardial hypoperfusion.
RESULTS: Width of the DRA and the number of DRA-affected myocardial segments were significantly reduced in the proposed method compared to the conventional approach (width: 1.3 vs. 2.9 mm, P < 0.001; number of segments: 2.6 vs. 8.7; P < 0.0001). The number of slices with severe DRA was markedly lower for the proposed method (by 10-fold). The reader-assigned image quality scores were similar (P = 0.2), although the quantified myocardial signal-to-noise ratio was lower for the proposed method (P < 0.05). Animal studies showed that the proposed method can detect subendocardial perfusion defects and patient results were consistent with the gold-standard invasive test.
CONCLUSION: The proposed free-breathing Cartesian FPP imaging method significantly reduces the prevalence of severe DRAs compared to the conventional approach while maintaining similar resolution and image quality. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:542-555.
© 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  Gibbs ringing; dark rim artifact; first pass perfusion; ischemic heart disease; myocardial perfusion; subendocardial ischemia

Mesh:

Year:  2016        PMID: 27532501      PMCID: PMC5550286          DOI: 10.1002/jmri.25400

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  33 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Circulation       Date:  2002-01-29       Impact factor: 29.690

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Safety of coronary reactivity testing in women with no obstructive coronary artery disease: results from the NHLBI-sponsored WISE (Women's Ischemia Syndrome Evaluation) study.

Authors:  Janet Wei; Puja K Mehta; B Delia Johnson; Bruce Samuels; Saibal Kar; R David Anderson; Babak Azarbal; John Petersen; Barry Sharaf; Eileen Handberg; Chrisandra Shufelt; Kamlesh Kothawade; George Sopko; Amir Lerman; Leslee Shaw; Sheryl F Kelsey; Carl J Pepine; C Noel Bairey Merz
Journal:  JACC Cardiovasc Interv       Date:  2012-06       Impact factor: 11.195

4.  Apodizing functions for Fourier transform spectroscopy.

Authors:  David A Naylor; Margaret K Tahic
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-11       Impact factor: 2.129

5.  Myocardial first-pass perfusion: influence of spatial resolution and heart rate on the dark rim artifact.

Authors:  Antonella Meloni; Nidal Al-Saadi; Geir Torheim; Nadja Hoebel; H Glenn Reynolds; Daniele De Marchi; Vincenzo Positano; Silvia Burchielli; Massimo Lombardi
Journal:  Magn Reson Med       Date:  2011-06-23       Impact factor: 4.668

6.  Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

Authors:  Behzad Sharif; Rohan Dharmakumar; Reza Arsanjani; Louise Thomson; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-17       Impact factor: 4.668

7.  Cardiac magnetic resonance myocardial perfusion reserve index is reduced in women with coronary microvascular dysfunction. A National Heart, Lung, and Blood Institute-sponsored study from the Women's Ischemia Syndrome Evaluation.

Authors:  Louise E J Thomson; Janet Wei; Megha Agarwal; Afsaneh Haft-Baradaran; Chrisandra Shufelt; Puja K Mehta; Edward B Gill; B Delia Johnson; Tanya Kenkre; Eileen M Handberg; Debiao Li; Behzad Sharif; Daniel S Berman; John W Petersen; Carl J Pepine; C Noel Bairey Merz
Journal:  Circ Cardiovasc Imaging       Date:  2015-04       Impact factor: 7.792

8.  Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: a comparison with positron emission tomography and coronary angiography.

Authors:  J Schwitter; D Nanz; S Kneifel; K Bertschinger; M Büchi; P R Knüsel; B Marincek; T F Lüscher; G K von Schulthess
Journal:  Circulation       Date:  2001-05-08       Impact factor: 29.690

9.  Patient adaptive maximal resolution magnetic resonance myocardial stress perfusion imaging.

Authors:  David P Ripley; Adam K McDiarmid; Ananth Kidambi; Akhlaque Uddin; Peter P Swoboda; Tarique A Musa; Bara Erhayiem; Gavin J Bainbridge; John P Greenwood; Sven Plein; David M Higgins
Journal:  J Magn Reson Imaging       Date:  2015-04-09       Impact factor: 4.813

10.  Variability of myocardial perfusion dark rim Gibbs artifacts due to sub-pixel shifts.

Authors:  Pedro Ferreira; Peter Gatehouse; Peter Kellman; Chiara Bucciarelli-Ducci; David Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2009-05-27       Impact factor: 5.364

View more
  3 in total

Review 1.  Updates on Stress Imaging Testing and Myocardial Viability With Advanced Imaging Modalities.

Authors:  Sandeep S Hedgire; Michael Osborne; Daniel J Verdini; Brian B Ghoshhajra
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-04

2.  Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification.

Authors:  Peter Kellman; Michael S Hansen; Sonia Nielles-Vallespin; Jannike Nickander; Raquel Themudo; Martin Ugander; Hui Xue
Journal:  J Cardiovasc Magn Reson       Date:  2017-04-07       Impact factor: 5.364

3.  Impact of incomplete ventricular coverage on diagnostic performance of myocardial perfusion imaging.

Authors:  Behzad Sharif; Manish Motwani; Reza Arsanjani; Rohan Dharmakumar; Mathews B Fish; Guido Germano; Debiao Li; Daniel S Berman; Piotr Slomka
Journal:  Int J Cardiovasc Imaging       Date:  2017-12-01       Impact factor: 2.357

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.